Iniciar sesión:
Votos - 3, Puntuación media: 4.3 ( )

Manual de usuario GE, modelo 390.252158

Fabricar: GE
Tamaño del archivo: 672.5 kb
Nombre del archivo: a8d56490-02c5-4a84-b905-c7929ce181f4.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Save This Manual For FutureReference. CRAFTSMAN° PROFESSIONAL 112 HP SHALLOW WELL WATER SYSTEM • Safety Instructions • Installation • Electrical • Maintenance • Repair Parts Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. PRINTED IN U.S.A. Form No. F642-9823 (9/2S/98) CONTENTS INTRODUCTION INTRODUCTION/WARRANTY .......................................... 2 Please read our instructions before installing and using your PUMP PERFORMANCE ....................................................... 3 shallow Well Water System. This will help you obtain the full benefits of the quality and convenience built into this MAJOR COMPONENTS ...................................................... 3 equipment. It will also help you avoid any needless service INSTALLATION ................................................................ 4-5 expense resulting from causes beyond our control which are ELECTRICAL ..................................................................... 5_6 not _:overed by our warranty. OPERATION ........................................................................ 7 MAINTENANCE ............................................................... 7-9 HELPFUL HINTS ............................................................... 10 TROUBLESHOOTING GUIDE ........................................... 11 REPAIR PARTS ............................................................. 12-14 FULL ONE YEAR WARRANTY ON CRAFTSMAN* WELL PUMP For one year from the date Of purchase, Sears will repair or replace well pump, free of charge, ff deft:cOve in material or workmanship. LIMITED WARRANTY ON CRAFTSMAN* PROFESSIONAL HYDRO-GLASS ° WELL PUMP After one year and through three years from the date of purchase, Sears will fumL_, free of charge, a replacement part for any d_fective part. You pay labor. FULL FIVE YEAR WARRANTY ON CRAFTSMAN _ CAPTIVE AIR TANK For rive years from date of purch___e, Sears will repair-or replace the tank, free of chaPge, if defective in material or workmanship. This x,_arTanty does not cover repairs or replacement parts necessary becaus._ of abuse or negligence, inclttding faiinre to install, adjust and operate this pump according to the instructions in the owners manual LIMITATION OF LIABILITY SEARS WILL NOT BE LIABLE FOR LOSS OR DAMAGE TO PROPERTY OR ANY INCIDENTAL OR CONSEQUENTIAL LOSS OR EXPENSE FROM PROPERTY D_LIIAGE DUE DIRECTLY OR INDIRECTLY FROM THE USE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. WARRANTY SERVICE LS"A VAILABLE BY SIMPLY CONTACTING THE NEAREST SEARS SERVICE CENTER/DEPARTMENT IN THE UNITED STA TEX his wan'anty applies only while this product is in the Unite,J States. This warranty gives you specific legal rights, and you may also have other rights which ,ra_ from state to state. Sears, Roebuck and Co., Dept. 817WA, Hoffman Estates, IL 60179 READ AND FOLLOW SAFETY INSTRUCTIONS! Carefully read and follow all safety instructions in this F[_,CAUTION]7Motor normally operates at high temperature manual or on pump. and will be too hot to touch. It is protected from heat damage during operation by an automatic internal cutoffswitch. ,_ This is the safety alert symbol. When you see this symbol on your pump or in this manual, look for one Before handling pump or motor, stop motor and allow to cool for 20 minutes. of the following signal words and be alert to the potential for personal injury! 1. To avoid risk of serious bodily injury and property damage, read safety instructions carefnily before installing warns about hazards that wiil cause serious pump. personal injury, death or major property damage if ignored. 2. Follow local and/or national plumbing and electrical [_WARNING ]w ares abou t hazard stha t will or ca n cause se-codes when installing pump, rious personal injury, death or major property damage if ig-3. Keep well covered while installing pump to prevent nored. leaves and other debris from falling into well, con taminating well and possibly damaging pump. & CAUTION ]warns about hazards that will or can cause 4. Protect pump and piping system from freezing. Allowing minor personal injury or property damage if ignored. pump or water system to freeze could severely damage The word NOTICE indicates special instructions which are pump and voids warranty. important but not related to hazards. LAWARNINGJTo avoid serious injury'and equip ] . . CAUTION ] Never rtm-pump dry. Running pi_np without ment damage, limit system pressure to 100 pounds water may cause pump to overheat, damaging seal and pos per square inch (PSI) or below at all times. Oversibly causing burns to persons handling pump. Fill pump pressure can cause tank blowup; install relief valve with water before starting. capable of passing full pump volume at 100 PSI. 5. With a new well, test well for purity before use. Consult local Health Department for procedure. [AWARNING]Never run pump aga...

Otros modelos de este manual:
Depuradores de agua - 390.252158 (672.5 kb)
Depuradores de agua - 390.252158 (672.5 kb)
Depuradores de agua - 390.252158 (672.5 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría