FOR CALIFORNIA INSTALLATIONS: • California regulations require the control setting to yield 4,000 grains of capacity per pound of salt. To meet these requirements, the SALT PER REGEN and CAPACITY must be set no higher than indicated below: Model Capacity Default Salt Default GNPR40L 16.5 KGr 4.0 lbs GNPR48L 15.2 KGr 3.6 lbs 12 Installation Instructions SYSTEM CAPACITY INPUTS SALT PER REGEN AND CAPACITY (CONT.) NOTE: Both SALT PER REGEN and CAPACITY inputs must be based on the SYSTEM CAPACITY INP
The computer monitors the electronic components and circuits for correct operation. If a malfunction occurs, an error code appears in the face plate display. The chart below shows the error codes that could appear, and the possible defects for each code. While an error code appears in the display, all face plate buttons are inoperable except the SELECT button. The SELECT button remains operational so the service person can make the MANUAL INITIATE ELECTRONIC DIAGNOSTICS to further isolate the
The size of the CIP container should be a minimum of three times the permeate rate. When set properly, the RO machine, the CIP pump, and the CIP container should be assembled in a loop configuration to recirculate the water through the machine and back to the container during cleaning. The size of the CIP container should be a minimum of three times the permeate rate. N GE recommends the use of a CIP or booster pump to provide the proper feed water pressure and quantity to the RO machine during
Save This Manual For Future Reference. I:RI:IFTSMI:IN° PROFESSIONAL 1/2 HP SHALLOW WELL WATER SYSTEM • Safety Instructions • Installation • Electrical • Maintenance • Repair Parts Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. PRINTED IN USA Form No F642-04075 (8/3/o4) CONTENTS INTRODUCTION INTRODUCTION/WARRANTY 2 Please read our mstructions before mstallmg and usmg }'our PUMP PERFORS*L_CE 3 Shallow Well Water System Tilts will help you obtain the full benefits of the qua]ity and conve
If the membrane element housings are to be removed to change out the membrane elements, at least 6-inches (15.2 cm) is required at the end of each membrane element housing and 24-inches (61 cm) behind the machine. 2.2 Plumbing The feed water source must be able to provide water quantity and pressures to maintain an operating feed water pressure of 30 - 60 psig (2.1 - 4.1 barg). If the feed water pressure with the machine is in excess of 60 psig (4.1 barg) or fluctuates by more than 5 psig (0.34
VALVE OUTLET i OPEN A NEARBY SOFT WATER FAUCET i 000 to 199 (continuaD = Repeats display for each gallon of water passing through the meter. B° The letter (P) and clash (or dashes) indicate POSI- If you don't get a reading in the display, with the TION switch operation. If the letter appears, the faucet ()pen, pull the sensor from the valve outlet switch is closed. If the clash shows, the switch is port. Pass a small magnet back and forth in front of ()pen. the sensor. You should get a reading i
0 PREPARATION AND START-UP............................................................................ 12 3. 1 Pretreatment for Water Purification............................................................... 12 3.2 Start-Up.......................................................................................................... 12 4.0 OPERATION AND MAINTENANCE..................................................................... 18 4.1 Daily Log Sheets.......................................
KEEP THE SOFTENER FROM FREEZING If the softener is installed where it could freeze (summer cabin, lake home, etc.), you must drain all water from it to stop possible freeze damage. To drain the softener: 1. Close the shut-off valve on the house main water pipe, near the water meter or pressure tank. 2. Open a faucet in the soft water pipes to vent pressure in the softener. 3. If a single bypass valve is installed, move the stem into bypass. See FIG. 12 on page 18. In a 3-valve bypass syst
(para GXWH20F solamente) — Venta al por menor, parte (WHKIT) (opcional) (2) adaptadors uniones de compresion de Lima — Partes de GE (WS35X10023) bronce de 3.4. con tuerca y ferula (para Papel de esmeril • Cinta de teflon® GXWH20F solamente) Destornillador Los accesorios opcionales estan disponibles (usando Cinta de teflon® (para GXWH20F) Visa, MasterCard o Discover) visitando nuestro solamente Para el modelo GXWH04F, es posible que se Website a ge.com o en el Departamento de Partes necesit