Iniciar sesión:
Votos - 3, Puntuación media: 4 ( )

Manual de usuario Continental, modelo CX3000

Fabricar: Continental
Tamaño del archivo: 643.77 kb
Nombre del archivo: 9eeafc43-a4b1-4285-b669-786d7e79713c.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


TABLE OF CONTENTS IMPORTANTSAFETYINSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . .3 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 CYCLE TIMES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 COST OF OPERATION . . . . . . . . . . . . . . . . . . . . . . . .5 SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 CHANGING THE FILTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..6 CHANGING THE UV LAMPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 RESETTING THE SERVICE LIGHTS . . . . . . . . . . . . . . . . . . . . . . . . .8 REPLACEMENTFILTERS AND ULTRAVIOLETLAMPS . . . . . . . . . . . . . . . . . .8 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 TYPICAL VERTICAL AND HORIZONTAL INSTALLATION . . . . . . . . . . . . . .10 LIMITED LIFETIME WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 PERFORMANCE DATAAND APPROVALS. . . . . . . . . . . . . . . . . . . . . . . .12 WIRING DIAGRAM . . . . . . . . . . . . . . . . . .. . . . . . . . . . .13 PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CX3000 EXPLODED VIEW . . . . . . . . . . . . . . . . . . 2 IMPORTANT SAFETY INSTRUCTIONS Before installing the CX3000 purifier, inspect for any signs of damage. During handling and installation, take care to protect the catalytic honeycomb side of the product from physical damage, as the aluminum-titanium core is very soft and can be easily damaged. Warning - Always unplug the power cord from the CX3000 air purifier when changing the filter or ultraviolet lamps. Never look into a burning ultraviolet lamp without proper eye protection as severe damage to the eyes can result. This product is rated for standard ambient air temperatures during heating and air-conditioning functions and not rated for elevated air temperatures in excess of 125 degrees fahrenheit. Do not attempt to clean the catalytic honeycomb core with cleaning solutions. The catalyst is radiated with short wave ultraviolet light during periods of non-air flow and is self-cleaning. Do not install insulation within 76MM or 3 inches of Luminaries. Access for service is required when mounting above ceilings or behind walls. Do not install in a position where the interior module can fall from an elevated position and cause injury to people or equipment below. SPECIFICATIONS Manufacturer: Continental Fan Manufacturing Inc. Model: CX3000 Voltage: 1/120V/60 Dimensions: 21" W x 25" H x 10.25" D Amps: 0.38 Watts: 44.8 Caution: Risk of fire - replace only with SP20T10 / 20 watt UV-C lamps Fuse: Replace only with AGC-l fuse Max Face Velocity: 625 fpm Max Air Flow: 2170 cfm UV Range: 254 NM (germicidal) Weight: 42 LBS Application: 3000 Sq. Feet Catalyst: Titanium Dioxide Particle Filter: Electrostatic Needled MERV -11 Service: UV LAMPS - 1 year FILTERS - 6 months 3 OPERATION The CX3000 installs in the air-inlet side of any heating and air conditioning system, up to five tons in size. Operation of the air-handler fan unit is required for air purification and sterilization to take place. Note: The ultraviolet lamps are wired to operate continuously. This feature allows the catalyst to burn off surface impurities, while cleaning and reactivating itself during periods of no airflow. The cost of operation is less than .07 cents per day. See operating cost section. The CX3000 combines three unique technologies to protect people against indoor air pollutants. Photo-Catalytic Titanium Oxidation, combined with high efficiency electrostatic MERV-11 particulate filtration, and germicidal ultraviolet lights, quickly reduce and eliminate toxic gas phase chemicals, lung damaging dust and airborne germs from the living environment. Many new homes have smart programmable thermostats that allow for automatic operation of the air-handler fan unit when there is no demand for heating or air conditioning. It is important that the CX3000 operates at least (25) minutes per hour (24) hours per day to remove toxic materials from the indoor environment. The length of operation depends on the location of the home or office in relation to point source pollution such as refineries, processing plants, automobile traffic, and areas that produce high levels of pollen. Individuals that are sensitive to mold spores, dust mites and chemicals, have respiratory problems such as asthma, emphysema, and chronic should extend the run time to at least (40) minutes per hour. To obtain maximum benefit from the CX3000 air purification recommended that the air-handler fan be set to run continuously. 4 CYCLE TIMES AIR CYCLES PER HOUR (Based on 3000 sq. ft.) Fan unit on 10 minutes per hour Air cycled (1) -------- times per hour Fan unit on 15 minutes per hour Air cycled (1.3) ------ times per hour Fan unit on 20 minutes per hour Air cycled (1....


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría