Iniciar sesión:
Votos - 3, Puntuación media: 3.7 ( )

Manual de usuario Oregon Scientific, modelo WS904

Fabricar: Oregon Scientific
Tamaño del archivo: 607.42 kb
Nombre del archivo: e8efec9a-3eaf-4f39-9e86-6b84189b50f7.pdf
Idioma del manual:itenfrde
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


1 Overview............................................................................ 2 Features............................................................................ 4 How to Use.......................................................................4 Precautions for use....................................................... Use of Aromatic Oil........................................................... 7 8 Care and Cleaning............................................................ 10 12 13 EU-Declaration of Conformity............................................ 13 EN INTRODUCTIONEN INTRODUCTION Thank you very much for purchasing our “WS904 Mini Aroma Diffuser”. This instruction manual contains useful information on the proper use and care of this product. In order to enjoy keep it for future reference. FOR YOUR SAFETY Follow closely the tips below to avoid causing danger to people. . Do not modify the product. For repairs, consult the vendor or our company. . Never do the following with the power cord of the AC adaptor: tamper, bend, pull, twist, modify, place near high temperature areas or objects, put heavy objects on it or squeeze it between objects. . Do not use the product when the power cord or DC plug of the AC adaptor is damaged or the power cord connection is loose. . If anything unusual occurs with the unit body or AC adaptor (e.g. abnormal odor and noise or abnormally high temperature), immediately stop using the product and pull the power cord out of the wall socket. Consult the vendor or our company. . Do not immerse the unit body or AC adaptor under water or splash them with water. 1 ENEN . Do not immerse the unit body or AC adaptor under water or splash them with water. . Do not plug or unplug the AC adaptor with wet hand. When not in use, pull the power cord out of the wall socket. . Do not touch the ultrasonic vibrating plate. This product is not a medical inhaler. Do not inhale mist directly from the mist outlet. . Do not insert any foreign objects such as pins or wires into the mist outlet or gaps between the unit parts. . Keep the product out of reach of babies and children. OVERVIEW 1. 4. Ultrasonic vibrating plate 2. 5. Mist outlet 3. Tank cover DC jack Water tank 2 EN EN 6. 7. 8. 9. 10. 11. 12. 13. Timer indicator LED Mist outlet Light switch Mist switch Watering cup DC plug Pouch AC adaptor 3 FEATURES EN FEATURES EN . Packed in an elegant and easy-to-carry pouch, which can carry a maximum of two aromatic oil bottles. . Aroma can be enjoyed everywhere and anywhere, even when travelling. . Only a drop or two of your choice aromatic oil can create a long-lasting scent in the air. . Amount of oil required can be lessened by mixing with water. . An option of 30 min, 60 min or 90 min can be set for the mist timer*. . Automatic power-off function and the interlocking LED light can ensure safety during bedtime*. . LED light consumes less electricity; it is more economical*. HOW TO USE 1. 2. water at room temperature. Do not use well water, mineral water or ionized alkaline water. Slide the watering cup to the left and detach from the unit. Fill the watering cup with water. Always use fresh tap 1. 2. 4 3. 4. 5. 6. * Aromatic 100% plant-derived essential oil 7. EN 5 EN EN 8. 9. * This product operates in Eco mode (intermittent operation). 3. Slide the tank cover up (circled by dotted line) and detach from the unit. 4. Pour water gently from the watering cup into the water !"# $ & '# $ & + / '# take care not to spill water on the product. 5. Put a drop or two of aromatic oil into the water tank. Use 100% plant-derived essential oil. Take care not to spill oil on the product. 6. Re-attach the tank cover by sliding it down. Do not remove the tank cover during operation. 7. Insert the DC plug of the AC adaptor into the DC jack on the rear body. Then, plug the AC adaptor into the wall socket (AC100-240V). 8. Press the mist switch to activate mist ejection. Make sure the air inlet on the right side of the unit is not blocked and the watering cup is detached. You can change the mist timer setting either to 30 min, 60 min, 90 min or OFF by pressing the mist switch repeatedly. 9. Press the light switch to turn on the LED light. 6 ENEN NOTE When the amount of water in the water tank is low, mist ejection will automatically stop and the LED light will turn off regardless of the remaining time of the mist timer. PRECAUTIONS FOR USE . < = = > ? surface with one hand and gently detach the tank cover with the other hand. Attach or detach the tank cover while pressing the ? Do not lift or tilt the unit when attaching or detaching. . Do not pour water into the mist outlet or directly from the faucet. . Avoid long continuous use of the product. A minimum of 30-min rest is needed after 30-min use. . Do not press the mist switch when the water tank is empty. . Before water pouring or cleaning, unplug the AC adaptor from the unit and make...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría