|
Resumen del manual
Make sure when installing the base the plated washer on the switch is raised approximately 3.16". The proving switch must be fully engaged. (See Figure 8) 14. With aluminum or foil tape, seal all joints and seams of the plenum near the mounting location to reduce any direct viewing of light. Figure 6 Figure 7 Figure 8 page 6 WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands. MAINTENANCE WARNING: Always unplug unit from the electrical outlet before commencing inspection and cleaning. NOTE: Wear disposable, non-absorbent protective gloves prior to inspection procedure in case of accidental breakage of glass. 1. We recommend inspecting and cleaning the lamp at least every 6 months. Frequency depends upon the environment. Such as: the type of air filter, duration of use and replacement cycle. 2. To maintain maximum output intensity, replace the UV-Aire lamp annually. The lamp should operate continuously for maximum lamp life and light effectiveness. REPLACEMENT PROCEDURE WARNING: Unplug unit from the electrical outlet before starting replacement procedure. NOTE: Wear disposable, non-absorbent protective gloves prior to replacement procedure in case of accidental breakage of glass. 1. Rotate the UV-Aire ballast assembly counterclockwise until it stops. (See Figure 9) 2. Remove the ballast assembly and lamp from the mounting base. (See Figure 7) 3. Remove the lamp from the lamp socket. (See Figure 6) 4. Install the replacement lamp into lamp socket. Do not handle the lamp with bare hands. Oils on the hands tend to reduce lamp intensity. 5. Wipe off the glass with the supplied alcohol wipe. 6. Position the ballast assembly power cord 90° to the viewport hole on the mounting base. (See Figure 9) 7. Slide the lamp though the hole in the mounting base. (See Figure 7) 8. Press the ballast against the mounting base. Rotate the ballast assembly clockwise until it stops and is locked in place. (See Figure 10) 9. After assembly is firmly in place, plug the power supply cord back into the standard electrical outlet. Check lamp operation by looking through the viewport hole. A blue glow should be seen in the duct. 10. After replacing the lamp, make sure to install the Lamp Replacement Label. Print the date on the label and apply to the side of ballast assembly. NOTE: If blue light leaks through any portion of plenum and/or around mounting plate, unplug power supply cord immediately and seal affected areas and/or rotate ballast and repeat step #8 above. 11. UV lamps contain a small amount of mercury, like a typical fluorescent lamp. Check with your local waste management authority for local disposal or recycling requirements. According to the EPA's Universal Waste Rule, these types of lamps may be disposed of into household waste. WARNING: Never touch broken lamp or internal contents of lamp. The lamp contains mercury. NOTE: In case of accidental exposure to internal contents of lamp, wash hands and any other affected skin area with mild detergent. Remove affected clothing immediately. If skin surface is pierced, seek medical attention immediately. Figure 9 Figure 10 TROUBLESHOOTING GUIDE 1. Check to make sure 120VAC power is available at the electrical outlet. 2. Do not wire the unit into the appliance fan circuit. This will cause premature ballast or lamp failure and void the warranty. For proper operation, the unit requires 120VAC at all times. 3. Pull back metal washer on mounting base. If lamp comes on, the base needs tightening to ensure that the safety switch is fully engaged. 4. If lamp does not light up, rotate ballast slightly clockwise or counterclockwise. 5. If lamp does not light up after rotating ballast, replace lamp. 6. If unit still does not light up after replacing lamp, replace unit. REPLACEMENT PARTS LIST LAMP Replacement Part Number 46511200 For replacement parts, contact Field Controls at: Phone: 1-252-522-3031 Fax: 1-252-522-0214 Email: sales@fieldcontrols.com CLEAN-UP OF BROKEN LAMPS (see warnings on page two of this manual) UV lamps contain a small amount of mercury, like a typical fluorescent lamp. DO NOT touch any of the mercury with your bare hands. 1. While wearing disposable, non-absorbent protective gloves, carefully pick up the large pieces of glass with your hands. 2. Then, vacuum the entire area with a standard household vacuum cleaner ensuring the removal of all lamp material. 3. Dispose of the pieces of glass, the vacuum cleaner bag, and the disposable gloves in a sealed garbage bag. 4. Check with your local waste management authority for local disposal or recycling requirements. According to the EPA's Universal Waste Rule, these types of lamps may be disposed of into household waste. 5. Wash hands and remove and wash clothes for added safety measures. WARNING: Never expos...
Otros modelos de este manual:Aire - UV-Aire 46511500 (1.23 mb)