Iniciar sesión:
Votos - , Puntuación media: ( )

Manual de usuario Field Controls, modelo UV-12

Fabricar: Field Controls
Tamaño del archivo: 1.28 mb
Nombre del archivo: 46360900.pdf

Idioma del manual:en

El documento se está cargando, por favor, espere
El documento se está cargando, por favor, espere

Resumen del manual


n the supply plenum or in the return plenum; preferably downstream from the air filter. For optimum “cleaning” effect on the ‘A’ coil, mount the unit in the supply plenum as close as possible to the ‘A’ coil. (See Figure 1) 2. Determine the type of duct you have. * Split system heat pumps are systems where the air handler and the air conditioning compressor are separate units. **Packaged units are systems where the air handler and the air conditioning compressor are built together and are installed outside of the building. page 3 WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands. IF YOU HAVE METAL DUCT: Apply supplied wet and stick mounting template to air duct in either a vertical o a. r horizontal position as shown in Figure 2B. b. Drill 1.8" diameter mounting holes at positions indicated on template. c. Cut out rectangular hole on template using a pair of tin snips or jigsaw. (See Figure 2B) Remove template. Figure 2B IF YOU HAVE FLEX DUCT: For installations on duct systems with a metallic main duct and flex duct branches, follow the instructions in figure 2A below. Figure 2A IF YOU HAVE DUCT BOARD: a. Mount the supplied metal mounting plate onto the duct with duct tape in either a vertical or horizontal position as shown in Figures 2B and 3. b. Bend tabs outward as shown in Figure 4. c. Using a knife or blade, cut out a rectangle opening in the duct using the mounting plate as a template. (See Figure 5) d. Remove the cut piece of duct. (See Figure 6) e. Bend both tabs down and through duct at first bend point. (See Figures 7 and 8) f. Bend both tabs at the second bend point up or down to pinch the duct material and grip the duct material. (See Figures 9 and 10) g. Using a screwdriver or pointed object, locate mounting holes by poking holes through the duct tape. (See Figure 11) Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 10 Figure 11 Figure 8 Figure 9 3. Remove base unit and cover from box. 4. Apply supplied Duct Seal Kit according to instructions included in kit. (See Figure 12) Figure 12 WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands. page 4 5. Determine whether to use flat or angled bracket. (Refer to UV-Aire “Bulb Mounting Bracket Selection” for aid in this decision) a. Flat Bracket Installation i. Remove the two hex nuts and flat bracket from included bagged hardware. ii. Install the flat bracket and secure to the unit base with the hex nuts provided. (See Figure 13) b. Angled Bracket Installation NOTE: For angled bracket mounting, refer to specifications outlined by Diagrams A & B for mounting distances in the “Angled Lamp Mounting Bracket Specifications” section. i. Remove the two hex nuts and angled bracket from included bagged hardware. ii. Install the angled bracket and secure to the unit base with the hex nuts provided. (See Figure 14) NOTE: Be sure to note location of lamp hole in bracket relative to unit base. 6. Mount the unit base to the duct using the four mounting screws provided. (See Figure 15) 7. Remove tag and alcohol from lamp. Wipe off lamp being sure not to ouch lamp with bare hands. The oils from your hands will reduce lamp output. 8. Insert lamp through hole until lamp cannot be inserted any further. (See Figure 16) 9. Swing swivel bracket over end of lamp. Hand-tighten the wing nut on stud. (See Figure 17) Be careful not to over tighten the wing nut. The porcelain at the lamp base may crack when over tightened. 10. Plug ballast plug into end of lamp. (See Figure 18) Figure 13 Figure 14 Figure 15 Figure 16 Figure 17 Figure 18 WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage or blindness. Never operate the UV-Aire Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with your hands. page 5 11. Replace cover on unit. Tighten side screws. (See Figures 19 & 20) 12. Plug the power cord into a standard electrical outlet. NOTE: Seal the joints and seams of the plenum near the mounting location to reduce any direct viewing of light. (See Figure 1) 13. Flip switch on box to the ON position. (Light on switch should be on, indicating power.) 14. Look through view port in the box cover to be sure lamp is working. You should see a blue glow. (The view port is covered with a plastic lens that blocks the UV-C rays.) 15. If the lamp is not glowing, follow steps 8-14 again. If lamp still does not glow, contact technical support at 1-252-522-3031 for further assistance. BULB MOUNTING BRACKET SELECTION AND INSTALLATION The UV-Aire units come...

Otros modelos de este manual:
Aire - UV-18 (1.28 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría