Iniciar sesión:
Votos - 3, Puntuación media: 4.3 ( )

Manual de usuario Hunter Fan, modelo 30023

Fabricar: Hunter Fan
Tamaño del archivo: 626.52 kb
Nombre del archivo: 41783.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


6. DO NOT tilt or move the Air Purifier while it is in operation. Shut off and unplug before moving. 7. DO NOT immerse the Air Purifier in water as permanent damage will occur. Refer to and follow the CLEANING AND FILTER REPLACEMENT instructions. Introduction Thank you for purchasing the PermaLife™ Air Purification System from Hunter Fan Company. You have purchased the latest development in portable Air Purification Systems. This system has been developed to improve the quality of the air you breathe. Your PermaLife™ Air Purification System outperforms other air purification systems by removing dust, smoke, and pollen particles as small as .1 microns in size. Room air is pulled in through the front grill and cleaned across the activated carbon pre-filter and the PermaLife™ system filter. Clean air is then released out the top grill in order to avoid stirring up settled particles. Model 30023 includes an Ionizer Using the ionizer improves the quality of air in the room. Negative ions are released into the air, and positively charged particles cling to the negative ions. These particles settle out of the air and can be vacuumed up during normal cleaning. These particles are also more easily trapped in the PermaLife™ system filter as they pass through the PermaLife™ Air Purification System. 41783-01 06/10/2005 2 © 2005 Hunter Fan Company 41783-01_rev 06.10.05.pmd 2 6/10/05, 8:23 PM 41783-01 06/10/2005 3 © 2005 Hunter Fan Company Figure 1 Power Control - Choose Hi, Med, or Lo speed. The red light will be illuminated when the power is ‘ON’. Ionizer - Allows you to turn the ionizer ‘ON’. The green light will be illuminated when the ionizer is ‘ON’. POWER IONIZER CONTROL RELEASE BUTTON (On each side) PERMALIFE™ FILTER WASHABLE PRE-FILTER FRONT GRILL COLOR CODED FILTER CHART Air Purifier Parts How the PermaLife™ System Works Below is an illustration of how the PermaLife™ air purification system works. Dust, pollen and other allergens are pulled into the air purification system and cleaned through the PermaLife™ Filter. Clean, purified air is then released into the room. Dust & Irritants Pollen & Allergens Odors Bacteria Pet Hair & Dander Cleanable Pre-filter Sub-Micron Filter Ionizer 41783-01_rev 06.10.05.pmd 3 6/10/05, 8:23 PM Using Your Air Purifier 1. Place your PermaLife™ Air Purification System on a hard, flat surface. We recommend placing it on a table top in order to achieve the best air circulation for the room. 2. Plug the unit into a 120V electrical outlet. 3. Select a speed by sliding the speed selector to the appropriate location. The red power light will be illuminated when you have selected a speed. 4. Turn the ionizer ‘on’, by sliding the ionizer switch to the ‘on’ position. The green light will be illuminated when the ionizer is ‘on’. NOTE: The ionizer can release negative ions when the fan is not blowing. If it is used consistently without the fan, the dust particles that are attracted to the negative ions may deposit on your walls and floors. To minimize these deposits, we recommend that you use the ionizer only when the fan is blowing (when the unit is on LO, MED, or HI speed). Cleaning Your Air Purifier Proper maintenance of your Hunter Air Purifier will help ensure years of trouble free service. Follow these steps to properly maintain your air purifier: 1. Approximately every 90 days, the outside of the unit should be cleaned with a soft, damp cloth. 2. If needed, the front grill can be removed from the unit and cleaned with soapy water. Simply remove the pre-filter before exposing the grill to water. 3. Follow the instructions in the Cleaning the Filter and Pre-Filter section to determine when to clean the filters. NOTES: •The air purifier must be unplugged during the cleaning process. • Be sure the unit is completely dry before plugging in and using. •Never immerse unit in water. Cleaning the Filter and Pre-Filter The PermaLife™ Filtration System uses a cleanable filter that never has to be changed, only cleaned. The proper time to clean the filter depends on usage and the environment. Use the following list to help determine if the filter should be cleaned: • Compare the color of the filter to the color coded chart on the inside of the housing. If the filter color matches the darkest color on the chart, you should clean the filter. • If you notice a decrease in air output or an increase in noise at any time during normal operation, the filter may be clogged. Clean the filter to return to normal operation. 41783-01 06/10/2005 4 © 2005 Hunter Fan Company 41783-01_rev 06.10.05.pmd 4 6/10/05, 8:23 PM 41783-01 06/10/2005 5 © 2005 Hunter Fan Company To clean the filter and pre-filter: 1. First, turn off and unplug the air purifier. 2. Next, remove the front grill. Press the buttons that are on each side of the front grill. Refer to Figure 1. When they are pressed inward, you will be able to pull the front grill forward, opening the unit. 3. Gently pull on the filter to remove it from the unit. Whi...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría