|
Resumen del manual
9 Parts List...............................................................................................................................................10 FOR YOUR OWN SAFETY 1. Read and understand instruction manual before installing or operating air cleaner. 2. To reduce the risk of injury disconnect the air cleaner from the power source (unplug) before servicing or changing filters. 3. If ceiling mounted, bottom of air cleaner must be at least 7 feet above the floor. 4. If ceiling mounted, mounts must be anchored to building structure which will support a minimum of at least 100 pounds. Never mount to surfaces such as dry wall or false ceiling grids, etc. 5. To reduce the risk of electrical shock, do not expose air cleaner to water or rain. 6. Never duct a machine directly into the air cleaner. 7. To avoid a potentially dangerous situation, do not use this equipment to filter volatile fumes or smoke. This air cleaner is designed and intended for the filtration of air borne wood dust only. It is neither designed or intended for any other purpose whatsoever. 8. Failure to comply may result in serious injury and / or property damage. The specifications in this manual are given as general information and are not binding. JET Equipment & Tools reserves the right to effect, at any time and without prior notice, changes or alterations to parts, fittings, and accessory equipment deemed necessary for any reason whatsoever. 5 Contents of Shipping Carton 1. Air Filtration Unit 1. Remote Control 2. AAA Batteries 4. Eye Bolts & Nuts 4. Mounting Brackets 8. Hex Cap Screws 8. Lock Washers 4. Foam Pads 1. Velcro Pad 1. Manual and Warranty Card Tools Required for Assembly • No. 2 Cross Point Screwdriver • 10mm Wrench • The air filtration unit does not require much assembly. You should take into consideration how and where you will place this unit. • It can be mounted horizontally and vertically. The unit can also be hung from the ceiling. • This unit will work best if it is located away from corners, and heating/cooling vents. • If using on sawhorses the air filtration unit should be clamped in place. • This unit is specifically designed to circulate and filter non-metallic dust, which is generated throughout the work area. Assembly CAUTION! Mounts must be anchored to building structure, which will support a minimum of at least 100 pounds. Never mount to surfaces such as dry wall or false ceiling _grids, etc._ 1. Remove all packing from inside of the unit by removing the outer filter and inner filters. 2. The air filtration unit can be hung from the ceiling. Remove four screws from the cabinet top (A, Fig. 1). 3. Hang the unit using four eyebolts (B, Fig. 1), and four hex nuts (C, Fig. 1) provided. T ! Fig. 1 6 4. The lock nut needs to be threaded almost all the way up the eyebolt. Screw the eye bolt into the hole and tighten lock nut against the cabinet top. You will need to hold the eyebolt so it does not spin while tightening the lock nut. 5. Repeat steps for remaining three eyebolts. Note: Make sure chain and ceiling hooks are properly rated for hanging this unit. Hang unit with a seven-foot clearance from the floor. CAUTION! Mounts must be anchored to building structure, which will support a minimum of at least 100 pounds. Never mount to surfaces such as dry wall or false ceiling _grids, etc._ 1. Four brackets can also be used for mounting to the ceiling, or wall. 2. Place one end of bracket underneath the lip of the cabinet. 3. Attach the bracket (A, Fig. 2) with two hex cap screws (B, Fig. 2) and two lock washers (C, Fig. 2). 4. Repeat steps for remaining three brackets. 5. Peel off the paper backing, on the foam pads, and stick to the bottom side of the machine’s four corners. Controls and Features Remote Control: Time button (A, Fig. 3) controls the three different settings. 2H will light up on the back of the unit with one press of the time button. The air filtration system will operate for 2 hours then shut off. 4H will light up on the back of the unit by pressing the time button twice. The air filtration system will operate for 4 hours then shut off. 8H will light up on the back of the unit by pressing the time button three times. The air filtration system will operate for 8 hours then shut off. Fig 3 7 Speed button (B, Fig. 3) controls the three different settings, Low, Medium and High. There is also a manual button (A, Fig. 4) on the backside of this unit which controls the speed. On/Off button (C, Fig. 3) turns the unit on and off. There is also a manual on/off button (B, Fig. 4) on the backside of the unit. Pressing this button will turn the machine on Low. Fuse switch (C, Fig. 4) will pop out in the case of overload. Wait 3-5 minutes and push the fuse in. Changing the Filters A WARNING To reduce the risk of injury disconnect the air cleaner from the power source (unplug) before servicing or changing filters. Failure to comply may cause se...
Otros modelos de este manual:Aire - AFS-1000B (294.6 kb)