Iniciar sesión:
Votos - 2, Puntuación media: 5 ( )

Manual de usuario Trion, modelo Air Boss DC-96

Fabricar: Trion
Tamaño del archivo: 493.94 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


competitor’s option • Programmable Smart Boss pulse control with digital pressure differential sensor • Allows for on and offline initiation of cleaning cycle • 15 digital display functions • Saves compressed air and increases filter life OPTIONS BENEFITS • Side Inlet • Acts as dropout box for sparks • Reduces overhead ductwork clearance • Explosion Vent Door/Latches • Latches designed to release, eliminating replacement of expensive membrane panels • Centrifugal Partial Width Fan • Eliminates need for volume outlet damper • Fan Silencer • Reduces sound levels to comply with OSHA and EPA standards 6 Trion Model Filters Sq. Ft. Media Hoppers Standard Height Standard Width Standard Depth Unit Weight lbs. DC-2 2 508 1 130 1/8” 32” 44 3/4” 1,025 DC-4M 4 1,016 1 130 1/8” 63 3/4” 33” 1,598 DC-4 4 1,016 1 155 1/8” 32” 44 3/4” 1,160 DC-6M 6 1,524 1 160 5/16” 83 3/4” 38 1/4” 2,205 DC-6 6 1,524 1 171 1/4” 80” 24” 1,888 DC-8 8 2,032 1 158 1/8” 63 3/4” 33” 1,790 DC-12 12 3,048 1 171 1/4” 83 3/4” 33 1/4” 2,465 DC-18 18 4,572 1 171 1/4” 88 3/4” 48 1/4” 3,395 DC-24 24 6,096 1 191” 105 25/32” 48 1/4” 4,050 DC-32 32 8,128 1 189 1/4” 105 25/32” 64 1/4” 5,025 DC-40 40 10,160 1 203 1/8” 80 1/4” 90 1/4” 4,880 DC-48 48 12,192 2 187 1/2” 106 1/4” 74 1/4” 5,575 DC-56 56 14,224 2 187 1/2” 122 1/4” 74 1/4” 6,245 DC-64 64 16,256 2 192 1/2” 138 1/4” 74 1/4” 6,980 DC-72 72 18,288 2 199 5/16” 154 1/4” 74 1/4” 7,657 DC-80 80 20,320 2 206 1/4” 170 1/4” 74 1/4” 8,450 DC-88 88 22,352 3 199 5/16” 186 1/4” 74 1/4” 9,495 DC-96 96 24,384 3 199 5/16” 202 1/4” 74 1/4” 10,236 DC-112 112 28,448 4 187 1/2” 244 1/2” 80 1/4” 12,490 DC-128 128 32,512 4 192 1/2” 276 1/2” 80 1/4” 13,960 Notes: 1) Models DC-2 thru DC-32 dimensions & weights include standard top mount blowers & top inlets. 2) Models DC-40 thru DC-128 dimensions & weights do not include ground mount/remote blowers. 3) All dimensions & weights include hopper/leg sets for a 55-gallon drum base. 7 Headquartered in Sanford, North Carolina Leading Technology for Cleaner Exhaust Air Since 1947 Air Purification Systems ...

Otros modelos de este manual:
Aire - Air Boss DC-112 (493.94 kb)
Aire - Air Boss DC-24 (493.94 kb)
Aire - Air Boss DC-32 (493.94 kb)
Aire - Air Boss DC-4 (493.94 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría