If they do not operate continuously, then interlocking them electrically with the TFP is acceptable. Consult a certified electrician. WHOLEHOUSE AND PORTABLECONSOLE MODELS ATTENTION The TFP can be installed in several different ways. Please read all suggested methods before attempting installation. Electrical The TFP is equipped with a standard power supply, on a 5’ 5” cable. Lighted ON/OFF switch. * LEAVE FOR HOMEOWNER NOTE: Due to ongoing research and product development, specifications, ratings and dimensions are subject to change without notice. TFP-06 TYPE 1 INSTALLATION TFP Directly Connected to Forced Air Heating System 1. Install 6” oval port collar (provided) on top and bottom of TFP (Fig. 1). Use (4) 8/32” X 3/8” screws (provided). 2. Remove protective backing from pieces of foam and stick them to the 4 corners of the TFP on the side being mounted against the plenum. 3. Remove the 4 mounting bolts from the back of the TFP cabinet. (Fig. 1) 4. Attach top and bottom mounting brackets (provided) vertical to the TFP cabinet and reinstall mounting bolts. 5. Lift the TFP into position. Edge of TFP must be positioned on plenum to allow clearance needed for latches. 6. Install the (4) 8/32” X 3/4” mounting screws (provided) through the brackets and into position. Tighten and secure. 7. TFP should now sit securely against the plenum with the foam in between. 8. Cut 2 - 6” holes in the plenum. Install ducting to join TFP to the return air plenum (Fig. 2). TFP TFP air cleaner TFP TFP Figure 1 NOTE: Do not support the weight of the TFP on the duct. Duct must be open and not pinched. NOTE: Due to possible noise transfer through the duct system, it may be preferable in some situations to hang the TFP a short distance from the plenum, and connect by running flexible ducting between them. Four nylon hanging straps are provided for this option. Install plate here Mounting bracket Foam gaskets Air Flow Supply Plenum FURNACE T F P Cold Air Return Air flow direction 6" port collars Access door Power supply Mounting bracket Ducting (not included) Clean (filtered) air port 1" Height Figure 2 Type 1 Installation * Direct connect to furnace/air handler return, or hang separately and connect to plenum with flexible ducting. Round port bent to oval Simply bend a standard duct fitting to the correct shape, and attach to the oval port using the same method as for a round port. 2 TYPE 2 INSTALLATION TFP Connected to Heat Recovery Ventilator LOCATION The TFP should be located in the main trunk of the fresh air to house line, after the Heat Recovery Ventilator (HRV) and before any branch lines. (Fig. 3) MOUNTING 1. Locate mounting bolts (4) on side of TFP cabinet for vertical hanging (Fig. 3) and remove. 2. Measure distance between the bolts and mark it on the floor/header joist where the TFP is to be hung. 3. Fasten hanging straps to floor joists using wide head nails or screws with washers. 4. Insert hanging bolts through prepunched holes in straps and lift TFP into position. Tighten and secure bolts. DUCTING 1. Install (2) 6” oval port collars (provided) on TFP cabinet with (8) 8/32” X 3/8” sheet metal screws provided (Fig. 3). 2. The ducting between the TFP and the HRV, and between the TFP and the main supply trunk line to the house, should be kept as straight as possible. 3. A relief opening or breathing T is required to prevent pressure differences. 4. A short piece (1-2 foot) of flexible ducting should be used on both sides of the TFP (Fig. 3). This will reduce vibration and noise transfer if present. NOTE: Please refer to the HRV installation manual for proper ducting of that appliance. Type 2 Installation *“Breathing T” is designed to assist in neutralizing pressure differences which can occur between HRV and TFP when joined tog...
Otros modelos de este manual:Aire - TFP2000 (152.04 kb)