• Changes to the electrical or mechanical installation are dangerous and must not be undertaken! They may also cause the extractor hood to malfunction. Simultaneous operation of the extractor hood with a heating appliance which is dependent on ambient air • Heating appliances which are dependent on ambient air, e.g. gas, oil, wood, or solid-fuel heaters, instantaneous water heaters, hot water boilers, hobs or ovens, and which draw combustion air out of the installation room and whose exhaust gases are conveyed to the exterior by a flue. RISK OF POISONING If the extractor hood is operated at the same time as a heating appliance which is dependent on ambient air, there is a risk of poisoning due to combustion gases being drawn back in. Safety instructions • Safe operation is possible provided the low pressure in the installation room of the heating appliance does not exceed 4Pa (0.04mbar). This can be achieved if the combustion air can flow through non-closable openings, e.g.in doors, windows, in conjunction with air intake/exhaust air wall boxes or by other technical measures. • Adequate intake air must therefore always be provided. • An intake/exhaust air wall box alone does not ensure compliance with the limit value. NOTE: When making your evaluation, always consider the entire ventilation system in the home. Include the advice of a competent heating engineer when making your evaluation. • If the extractor hood is used in circulating air mode only, it can be operated without any restrictions. Special information for gas cookers • When installing the extractor hood above gas hobs, observe the appropriate national statutory regulations (e.g. in Germany: Technische Regeln Gasinstallation TRGI). • Observe the currently valid installation regulations and instructions of the gas appliance manufacturer. • During installation, ensure that only one side of the extractor hood is situated directly next to a high-sided unit or a wall. Otherwise, there is a risk of heat build-up. The gap between the extractor hood and the wall or high-sided unit must be at least 50 mm. RISK OF BURNS Do not operate more than 2 gas cooking areas simultaneously over a period of max. 15 minutes at maximum thermal load. Due to the effect of the heat there is a risk of burns if the surfaces of the housing are touched! • Note that one large burner of more than 5 kW (Wok) is equivalent to the power of 2 gas burners. • The extractor hood may be damaged by the intense heat. • Never operate a gas cooking area without a cooking utensil on it. Regulate the flame in such a way that it does not project over the cooking utensil. Safety instructions Proper use • Clean the extractor hood thoroughly before using for the first time. • Before cleaning and servicing the extractor hood, isolate it from the power supply by pulling out the mains plug or switching off the fuse. • Bulbs (especially halogen bulbs) become very hot during operation. Even some time after the appliance has been switched off, there is still a risk of burns! • Before changing bulbs, isolate the extractor hood from the power supply and leave the bulbs to cool down! • Do not operate the extractor hood without bulbs inserted. • Always switch on the extractor hood if a hotplate is being used. If the extractor hood is not switched on, condensation may form. As a result, the appliance may corrode. • Do not place any objects on the extractor hood. RISK OF FIRE Do not flambe under the extractor hood or work with a naked flame. When switched on, the extractor hood draws flames into the filter. There is a risk of fire due to deposits on the grease filter! • Do not leave pans, frying pans or deep-fat fryers unattended if you are cooking food with oils or fats, e.g. chips. Overheated oils or fats can easily ignite! • A risk of fire can be prevented by cleaning the grease filters regularly and changing the activated-carbon filter in good time. • Never operate the extractor hood without grease filters. Correct installation • Check the manufacturer’s specifications for the cooker to determine whether an extractor hood can be operated over it. • If the manufacturer of the cooker has not specified any significant safety distances, the following minimum distances apply – 550 mm between electric hob and the lower edge of the extractor hood, Fig.1. – 650 mm between gas hob (upper edge of pan support) and the lower edge of the extractor hood, Fig.1. • If various cookers are used, the greatest indicated distance applies. • The width of the extractor hood must correspond to the width of the cooking area. • The extractor hood must not be installed over a solid fuel heating appliance which may be a fire risk (e.g. flying sparks) unless the heating appliance has a closed, non- detachable cover and the country-specific regulations are observed.This restriction does not apply to gas cookers and gas hobs. • To avoid damaging the hob, cover it when installing the extractor hood. Operating modes • The extractor...

Otros modelos de este manual:
Campanas - CD939550/01 (1.39 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría