Iniciar sesión:
Votos - 0, Puntuación media: 0 ( )

Manual de usuario Bosch, modelo D79T48N0GB/01

Fabricar: Bosch
Tamaño del archivo: 1 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Dispose of packaging materials properly (see Installation instructions). This extractor hood is designed for domestic use only. Carefully clean the extractor hood before switching on for the first time. Do not place any objects on the extractor hood. Operating procedure The most effective method of removing kitchen fumes is to: . switch on the extractor hood when you start cooking. . switch off the extractor hood a few minutes after you finishing cooking. . The fans in this appliance can be switched to the desired setting by hand (manual mode) or can be controlled fully automatically with the automatic function according to your requirements (automatic mode). Automatic mode / Manual mode Fan – off – Fan settings – lower – Fan – on – Fan settings – higher – Fan run-on / Intermittent ventilation Fan on / off Display: . Fan settings / Intensive setting . Saturation – grease filter (#) . Saturation – activated carbon filter (a) Light on / off Switching on manual mode: Press the Lor + button. . The fan starts at Setting }. Switching on the fan settings/intensive setting: 1. To increase the fan settings or switch on the intensive setting c, press the + button. . The intensive setting operates at maximum power which should be used only briefly. If the intensive setting is not switched off manually, the fan automatically switches back to Setting }after 10 minutes. 2. To switch off the intensive setting c or switch back to fan settings ~ – } – |and switch off the extractor hood completely, press the – button. Switching over to automatic mode: . To switch from manual mode to automatic mode at any time, press the U button. Operating procedure Switching on automatic mode: Press the Ubutton. . The optimum fan setting |, } or ~ is automatically set via a sensor. – If there are no kitchen fumes, automatic mode remains active at setting {. Intensive setting: 1. To switch on the intensive setting c, press the + button. . Automatic mode has been switched off. . The intensive setting operates at maximum power which should be used only briefly. If the intensive setting is not switched off manually, the fan automatically switches back to the optimum fan setting after 10 minutes. 2. To switch off the intensive setting, press the – button. . Automatic mode has been switched on again. Switching over to manual mode: . To switch from automatic mode to manual mode at any time, press the U button. Intermittent ventilation . Used for ventilating the kitchen at hourly intervals at the lowest fan setting, round the clock. Switching on: . Before intermittent ventilation can be switched on, the appliance must be switched off. Press the button. . The fan runs for 5 minutes at Setting |, then switches off for 55 minutes. This process is repeated every hour. Switching off: Press the button. Operating procedure Switching off With fan run-on started from manual mode: Press the button. . The fan runs at the setting last selected. . The dot on the display flashes. . After 10 minutes the fan switches off and the displays go out. With fan run-on started from automatic mode: Press the button. . When fan setting | is reached, fan run-on starts. . Fan run-on cannot be set if automatic mode has already been switched back to setting {. . As long as the dot on the display flashes, fan run-on is active. . After 10 minutes the fan switches off and the displays go out. Without fan run-on: Press the Lbutton. Light . The light can be used at any time, even when the appliance has been switched off. Switching on/off: Press the a button. Sensor control In automatic mode sensors on the extractor hood detect the density of the kitchen fumes. Depending on the setting of the sensors, the extractor hood automatically switches on and off. The sensor control responds most quickly at the highest setting. . Factory setting: Setting @. . Factory setting: Setting {. . Factory setting: Setting O. If the sensor control responds too quickly or too slowly, it can be changed accordingly. 1. Press and hold down Automatic button. 2. Press the + or – button to display the current setting. 3. You can now change the sensor control setting with the + or – button. 8 Filters and maintenance Grease filters: Metal filters are used to trap the greasy element of the vapours that develop during cooking. The filter mats are made from noncombustible metal. Caution: As the filter becomes more and more saturated with grease, not only does the risk of it catching fire increase but the efficiency of the extractor hood can also be adversely affected. Important: By cleaning the metal grease filters at appropriate intervals, the possibility of them catching fire as a result of a build-up of heat such as occurs when deep-fat frying or roasting is taking place, is reduced. Saturation indicator: ~ When the grease filters reach saturation point, an acoustic signal is sounded for 6 seconds after the fan has switched off, and an ~ appears in the display. The grease filters should be cleaned straight ...

Otros modelos de este manual:
Campanas - D79T48N0GB/02 (1 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría