Resumen del manual
Switching on: . Before intermittent ventilation can be switched on, the appliance must be switched off. Press the button. . The fan runs for 5 minutes at Setting |, then switches off for 55 minutes. This process is repeated every hour. Switching off: Press the button. Operating procedure Switching off With fan run-on started from manual mode: Press the button. . The fan runs at the setting last selected. . The dot on the display flashes. . After 10 minutes the fan switches off and the displays go out. With fan run-on started from automatic mode: Press the button. . Fan run-on does not start until the automatic function has switched the fan back to Setting |. . The dot on the display flashes. . After 10 minutes the fan switches off and the displays go out. Without fan run-on: Press the Lbutton. Light . The light can be used at any time, even when the appliance has been switched off. Switching on/off: Press the a button. Special functions Adjusting the sensitivity of the sensor control: 1. Press and hold down the automatic button. 2. To display the current sensitivity, press the + or – button. 3. You can now change the sensitivity of the sensor control by pressing the + or – button. . Factory setting: @. . Lowest setting: {. . Highest setting: O. Switching on the light automatically, e.g. via a timer: . Fan and light must be switched off. Switching on: Simultaneously press the a and L buttons. . After approx. 3 seconds the light switches on to acknowledge the setting. Switching off: Repeat the process with the light switched on. . After approx. 3 seconds the light switches off to acknowledge the setting. Filters and maintenance Grease filters: Metal filters are used to trap the greasy element of the vapours that develop during cooking. The filter mats are made from noncombustible metal. Caution: As the filter becomes more and more saturated with grease, not only does the risk of it catching fire increase but the efficiency of the extractor hood can also be adversely affected. Important: By cleaning the metal grease filters at appropriate intervals, the possibility of them catching fire as a result of a build-up of heat such as occurs when deep-fat frying or roasting is taking place, is reduced. Saturation indicator: When the grease filters reach saturation point, an acoustic signal is sounded for 10 seconds after the fan has switched off, and an # appears in the display. The grease filters should be cleaned straight away. Cleaning the metal grease filters: . The filters can be cleaned in a dishwasher. It is however possible that they will become slightly discoloured. Important: Metal filters that are saturated with grease should not be washed together with other dishes etc. . When cleaning the filters by hand, soak them in hot soapy water first of all. Then brush the filters clean, rinse them thoroughly and leave the water to drain off. Removing and inserting the metal grease filters: Warning: The halogen bulbs must be switched off and cool. 1. Press the catch on the grease filters inwards and fold the filters down. 2. Clean the filters. 3. Insert the clean filters back into the hood. 4. Cancel the #in the display. . Press the L button for at least 3 seconds. The # is cancelled. Filters and maintenance Activated carbon filter: For neutralizing odours in recirculating mode. Inserting the filter: Warning: The halogen bulbs must be switched off and cool. 1. Remove the metal filters (see "Removing and inserting the metal grease filters"). 2. Insert the activated carbon filter. Saturation indicator: When the activated carbon filter reaches saturation point, an acoustic signal is sounded for 10 seconds after the fan has switched off, and a aappears in the display. The activated carbon filter should be replaced straight away. Removing the filter: Warning: The halogen bulbs must be switched off and cool. 1. Remove the metal filters. 2. Press the catches at both sides of the filter inwards and lift the carbon filter down and out. 3. Engage the catches at both sides. 4. Insert the metal grease filters (see "Removing and inserting the metal grease filters"). 5. Cancel the a in the display. . Press the Lbutton for at least 3 seconds. The ais cancelled. 3. Insert the metal grease filters. Replacing the activated carbon filter: . A replacement filter can be obtained from any authorized dealer (see optional accessories). . Use original filters only. By doing so you will obtain maximum performance from your extractor hood. Disposing of the old activated carbon filter: . There are no pollutants in the activated carbon filters. They can therefore be disposed of as part of your normal domestic refuse. Cleaning and care Disconnect the extractor hood from the electricity supply by pulling out the mains plug or switching it off at the fuse box. . At the same time as you clean the grease filters, clean off any grease from all accessible parts of the housing. This significantly reduces the fire hazard and ensures that the extractor ...
Otros modelos de este manual:Campanas - D8985N0GB/04 (597.28 kb)
Campanas - D8985N0GB/05 (597.28 kb)