Prior to installation For optimum extractor hood efficiency: . Short, smooth air exhaust pipe. . As few bends in the pipe as possible. . Diameter of pipe to be as large as possible and no tight bends in pipe. If long, rough exhaust-air pipes, many pipe bends or smaller pipe diameters are used, the air extraction rate will no longer be at an optimum level and there will be an increase in noise. . Round pipes: We recommend Internal diameter: 150 mm (at least 120 mm). . Flat ducts must have an internal cross- section that equates to that of round pipes. There should be no sharp bends. l120 mm approx. 113 cm2 l150 mm approx. 177 cm2 . If pipes have different diameters: Insert sealing strip. . For exhaust-air mode, ensure that there is an adequate supply of fresh air. Circulating-air mode . With activated carbon filter if exhaust-air mode is not possible. The complete installation set can be obtained from specialist outlets. The corresponding accessory numbers can be found at the end of these operating instructions. Connecting a l150 mm exhaust-air pipe: . Mount the pipe directly onto the air outlet on the hood. Connecting a l120 mm exhaust-air pipe: . Attach the reducing connector directly to the air pipe. . Attach the exhaust-air pipe to the reducing connector. Prior to installation Preparing the ceiling . The ceiling must be flat and horizontal. . Ensure that the ceiling is capable of providing a firm hold for mounting screws and plugs. The enclosed plugs are suitable for concrete and stonework. If the ceiling is made of any other material, use appropriate mounting components. Weight in kg: Exhaust air Recirculating air 38,6 39,3 We reserve the right to construction changes within the context of technical development. Changing over from exhaust- air to recirculating mode Changing the electronic control system to recirculating mode: . The standard factory setting is for operation in exhaust-air mode. . To change the mode, the extractor hood must have been connected up and should be switched off. 1. Press and hold the 0 button. 2. While { is displayed, press the button until a is displayed. When this has taken place, release the buttons. . a goes out shortly afterwards. The electronic control system will then have been set to recirculating mode. . By repeating steps 1 and 2, you can change the electronic control system back to exhaust-air mode (# in display). Electrical connection WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: Fitting a Different Plug: The wires in the mains lead are coloured in accordance with the following code: Green and Yellow – Earth Blue – Neutral Brown – Live If you fit your own plug, the colours of these wires may not correspond with the identifying marks on the plug terminals. This is what you have to do: 1. Connect the green and yellow (Earth) wire to the terminal in the plug marked ‘E’ or with the symbol ( ), or coloured green or green and yellow. 2. Connect the blue (Neutral) wire to the terminal in the plug marked ‘N’ or coloured black. 3. Connect the brown (Live) wire to the terminal marked ‘L’, or coloured red. The extractor hood should only be connected to an earthed socket that has been installed according to relevant regulations. If possible, site the earthed socket directly above the chimney panelling in the ceiling. Electrical data: Are to be found on the name plate inside the appliance after removal of the filter frame. Before undertaking any repairs, always disconnect the extractor hood from the electricity supply. Length of the connecting cable: 1.30 m. If it is necessary to wire the extractor hood directly into the mains: The extractor hood should only be connected to the electricity supply by a properly qualified electrician. A separator must be installed in the household circuit. A suitable separator is a switch that has a contact gap of more than 3 mm and interrupts all poles. Such devices include circuit breakers and contactors. If the connecting cable for this appliance is damaged, the cable must be replaced by the manufacturer or his customer service or a similarly qualified person in order to prevent serious injury to the user. This extractor hood corresponds to EC regulations concerning RF interference suppression. Installation The extractor hood is designed to be fitted to the kitchen ceiling or a rigid suspended ceiling. Ensure that the minimum distance between hotplate and extractor hood is 550 mm for electric hotplates and 650 mm for gas hotplates. 1. Mark the centre point of the extractor hood on the ceiling. 2. Using the template, mark screw positions on the ceiling. 3. Drill 4x 8 mm holes and insert wall plugs flush with the ceiling. 4. Determine the overall height of the support frame. – This is the height of the ceiling, the height of the base and the distance between the hob and extractor hood. Exhaust air 430 -710 Circulating air 430 -750 min. 550 electric 650 gas 15 Installation 08. Insert the extractor hood over the installation aids on the s...
Otros modelos de este manual:Campanas - I91T58N0GB/01 (672.46 kb)