|
Resumen del manual
The appliance can only be used safely if it is correctly installed according to the safety instructions. Retain the instructions for subsequent use or for the next owner. This appliance is designed to be used in the home only. The manufacturer is not liable for damage which is caused by improper use or incorrect operation. Danger of suffocation! from packaging material. Never allow children to play with packaging material. After unpacking the appliance, check it for visible damage. Do not connect the appliance if it has been damaged in transit. These instructions apply to several appliance models. It is possible that individual features are described which do not apply to your appliance. Adults and children must never use the appliance unsupervised if they are not physically or mentally capable of doing so or if they lack the knowledge and experience to operate the appliance correctly and safely. Never allow children to play with the appliance! Please contact our customer service regarding any queries or faults (see list of customer service centres) . When calling, please quote the following numbers: E- Nr. FD The numbers can be found on the rating plate inside the appliance (to do this, remove the metal-mesh grease filter). Enter the numbers in the above box so that you can easily find them when required. Installation Mortal danger, risk of intoxication! Due to combustion gases sucked back in. Never operate the appliance in the exhaust air mode at the same time as a room air-dependent heat-producing appliance unless an adequate supply of fresh air is ensured. Room air-dependent heat-producing appliances (e. g. gas, oil, wood or coal-operated heaters, continuous flow heaters or water heaters) obtain combustion air from the room in which they are installed and discharge the exhaust gases into the open through an exhaust gas system ( e.g. a chimney) . In combination with an activated vapour extractor hood, room air is extracted from the kitchen and neighbouring rooms - a partial vacuum is produced if not enough fresh air is supplied. Toxic gases from the chimney or the extraction shaft are sucked backed into the living space. ¦ Adequate incoming air must therefore always be ensured. ¦ An incoming/ exhaust air wall box alone will not ensure compliance with the limit. Safe operation is possible only whenever the partial vacuum in the place where the firing equipment is installed does not exceed 4 Pa (0.04 mbar). This can be achieved whenever the air needed for combustion is able to enter through openings that cannot be sealed, for example in doors, windows, incoming/exhaust air wall boxes or by other technical means. In any case, consult your responsible chimney sweep. He is able to assess the house's entire ventilation setup and will suggest the suitable ventilation measures to you. Unrestricted operation is possible if the vapour extractor hood is o...
Otros modelos de este manual:Campanas - JD66GW50/02 (1.67 mb)
Campanas - JD66GW50/03 (1.67 mb)
Campanas - JD66GW50/04 (1.67 mb)
Campanas - JD69GW50/01 (1.67 mb)