Iniciar sesión:
Votos - 4, Puntuación media: 3.5 ( )

Manual de usuario Americana Appliances, modelo RM2862

Fabricar: Americana Appliances
Tamaño del archivo: 466.45 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Total refrigerated volume is 8 cu.ft. for the model RM2862. DEFROSTING Shut off the refrigerator by pressing the main power ON/OFF button to the UP (OFF) position. Empty the refrigerator, leaving the drip tray under the finned evaporator, and the cabinet and freezer doors open. Defrosting time can be reduced by filling the ice trays with hot water and placing them in the freezer compartment. ! CAUTION DO NOT use a hot air blower. Permanent damage could result from warping the metal or plastic parts. DO NOT use a knife or an ice pick, or other sharp tools to remove frost from the freezer compartment. They can create a leak in the ammonia system. When all the frost has melted, dry the interior of the refrigerator with a clean cloth. Replace all food and set the thermostat to the COLDEST temperature setting for a few hours. Then reset the thermostat to the desired setting, usually at mid setting. CLEANING Cleaning the refrigerator is usually done after it is defrosted or put into storage. To clean the interior liner of the refrigerator, use lukewarm weak soda solution. Use only warm water to clean the finned evaporator, gasket, ice tray and shelves. NEVER use strong chemicals or abrasives to clean these parts, as the protective surfaces will be damaged. It is important to always keep the refrigerator clean. SHUT OFF- (STORAGE PROCEDURE) Shut off the refrigerator by pressing the main power ON/ OFF button to the UP (OFF) position. If the refrigerator will not be in operation for a period of weeks, it should be emptied, defrosted, cleaned and the doors left ajar. The ice trays should also be dried and kept outside the cabinet. ! WARNING DO NOT store explosive substances in the refrigerator, such as cigarette lighter gas, gasoline, ether or the like. NOTE: Sodium chromate is used for corrosion protection (less than 2 weight % of the coolant). CLIMATE CONTROL During the summer months of high temperatures and humidity, the metal frame between the freezer and fresh food compartments may have water droplets forming. The number of water droplets will increase if the vehicle isn’t air conditioned during these months. This refrigerator comes standard with a 12 volt (DC) climate control that will evaporate the water droplets when they form. To have the climate control on, you position the switch (“G” see figure 2) located beneath the top decoration panel that houses the control panel to ON. The climate control can be left on continuously or only used when temperatures require it. NOTE: The climate control will draw 12 volt DC power continuously when in the ON position. It should be turned OFF when a charging source is not available. GAS EQUIPMENT ASSEMBLY SOLENOID VALVE INLET FITTING MANUAL SHUTOFF VALVE Shown in open position PRESSURE TEST PORT FIG. 12 BURNER JET ELECTRIC EQUIPMENT HEATER(S) The heat necessary for the operation of an absorption cooling unit is supplied by an electric heater mounted in a pocket of the boiler system. The 3-WAY Model is equipped with two electric heaters, one for 120 volt AC and one for 12 volt DC. The 2-WAY Model is equipped with one electric heater for 120 volt AC. To replace the heater proceed as follows: 1. Disconnect the wall plug, and the 12 volt wires. 2. Remove the power module cover see FIG. 1. 3. Disconnect the heater leads. 4. With a pair of pliers unfold the lug holding the lid of the boiler casing and open the lid. 5. Remove some insulation wool so that the heater is accessible. 6. Turn and lift the heater out of its pocket. 7. Fit the new heater into the pocket. 8. Connect the leads and put on the power module cover. 9. Reset the insulation and close the lid of the boiler. FUSES These models are equipped with 2 fuses in the power module. RM2663 is equipped with an extra in-line fuse for the 12 volt DC heater Power module To replace fuse(s) proceed as follows. 1. Disconnect the wall plug, and the 12 volt wires. 2. Remove the power module cover. See FIG. 1. 3. Snap the fuse out of the fuse holder. 4. Fit a new fuse in to the fuse holder. 5. Replace the power module cover. Control system 3 Amp AC heater 5 Amp In-line fuse The 3-Way model RM2663 is equipped with a 30 amps in-line fuse for the 12 volt DC heater. SPARK ELECTRODE BURNER TUBE BURNER MOUNTING SCREW MAINTENANCE & SERVICE The user should be aware of service that must be done on a regular schedule to keep the refrigerator operating properly. The service should only be performed by a qualified technician who is familiar with LP gas systems and refrigerators. 1. REFRIGERATOR REMOVAL Before working on the refrigerator, make sure the AC voltage and DC voltage leads are disconnected. Shut off the gas supply at the LP tank. Disconnect the gas supply line at the rear of the refrigerator, see FIG. 1. Always use a back up wrench when loosening and tightening connections. Cap the gas supply line, loosen the screws anchoring the refrigerator to the enclosure and slide the refrigerator out of the compartment. When replacing the refri...

Otros modelos de este manual:
Refrigeradores - RM2662 (466.45 kb)
Refrigeradores - RM2663 (466.45 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría