Resumen del manual
The mode automatically converts to refrigerated holding temperature at the end of the chill cycle. QUICK FREEZE … The mode for rapid freezing and frozen food maintenance by internal product probe temperature ortime within a temperature range of -10°F to +10°F (-23°C to -12°C). The mode automatically converts to a frozen foodholding temperature at the end of the quick freeze cycle. START/ STOP … Button used to initiate operating modes, set time andtemperatures, and to set specific chiller program functions. PROGRAM … Button used to modify or select specific chiller programming functions. QUICKCHILLER • INSTALLATION/OPERATION/SERVICE MANUAL • 12. OPERATIONOPERATION The date and time will appear in the display when the power key is pressed to the OFF position. All operating modes can be initiated when the power key is pressed to the ON position and SELECT: MODE, PRESETS, and PROGRAM appears in the display. To initiate any Quickchiller operating mode, power must initially start from the OFF position or an operating mode must be halted by pressing the START/STOP key so that the SELECTION SCREEN appears on the display. NOTE: With the exception of the QC-3 counter top Quickchiller model, the Alto-Shaam name on the control panel will illuminate whenever the power key is pressed to the ON position. H O L D T E M P Starting from the OFF position, press the NOTE: THE MODIFIED COMPARTMENT TEMPERATURE IS power key ON. The SELECTION NOT STORED OR SAVED UNTIL THE START SCREEN will appear on the display. The BUTTON IS PRESSED TO BEGIN QUICKCHILLER compressor will become energized and OPERATION. will begin to operate if required by the sensors. Press the START/STOP key to begin operation of the Quickchiller in the Press the HOLD TEMP key. The display Hold Temp mode. will indicate the last operator set internal compartment temperature. The display will indicate: 1. The length of time the chiller is To change the displayed temperature, operating in the Hold Temp mode. press the upor downarrow key to 2. The temperature set by the operator. increase or decrease the temperature 3. The air temperature inside the display within the refrigeration storage chiller compartment. parameters of the Hold Temp mode. 4. The temperature of all food probes. WHEN IN THE HOLD TEMP MODE: Press the UP arrow key to display the maximum sensor temperature achieved during the completed chill cycle. Press the DOWN arrow key to display the minimum sensor temperature achieved during the completed chill cycle. NOTE: NO DISPLAY DATA IS AVAILABLE DURING THE SENSOR STABILIZATION PERIOD CONSISTING OF THE FIRST TWO MINUTES OF THE INITIAL STARTING CYCLE . #8405 — QUICKCHILLER INSTALLATION, OPERATION, AND MAINTENANCE Pg. 13. OPERATIONOPERATION QUICK FREEZE Press the START/STOP key. Starting from the OFF position, 3. 1. press the power key ON. The Display will require the operator to select The Alto-Shaam name will illuminate and the between quick freezing by PROBE or by TIME. SELECTION SCREEN will appear on the display. The compressor will become energized and will begin to operate if required 4. Select the desired Quick Freeze method by by the sensors. pressing the rightor leftarrow keys. 2. Press the QUICK FREEZE key. After the selection has been made, press the START/STOP key. The display will indicate the last operator set internal compartment temperature. NOTE: MODIFIED COMPARTMENT TEMPERATURE IS NOT STORED OR SAVED UNTIL THE START BUTTON IS To change the displayed temperature, press the upor PRESSED TO BEGIN QUICKCHILLER OPERATION. downarrow key to increase or decrease the temperature displayed within the parameters of the Quick Freeze mode. #8405 — QUICKCHILLER INSTALLATION, OPERATION, AND MAINTENANCE Pg. 14. OPERATIONOPERATION QUICK FREEZE TIME If time was selected … The display will indicate the last period of time set by the operator. To change the displayed time, press the rightor leftarrow keys to select between hours or minutes and the upor downarrow key to increase or decrease the time. Press the START/STOP key. The Display will indicate the last set holding temperature. To change the displayed temperature press the upor downarrow key to increase or decrease the temperature display to any point within Quickchiller parameters for holding frozen product. After selections have been made, press the START/STOP key. The Quickchiller will begin operating in the Quick Freeze “time” mode. When chilling by time, the display will indicate a count-down of the time, the air temperature, and the temperature of each food probe. After time has expired, the chiller will automatically convert to the set holding mode. PROBE If probe was selected … The display will indicate the last temperature set by the operator for each probe. To change the displayed probe temperature(s), press the rightor leftarrow keys to select each probe and the upor downarrow key to increase or decrease probe temperature. Press the START/STOP key. The Display will indicate the last set hol...
Otros modelos de este manual:Refrigeradores - QC-100 REMOTE (3.28 mb)
Refrigeradores - QC-20 (3.28 mb)
Refrigeradores - QC-3 (3.28 mb)
Refrigeradores - QC-40 (3.28 mb)