|
Resumen del manual
1 Unplug the sanitizer. Slightly lift the drip tray and pull it out. Rinse the drip tray and wipe it clean with a damp cloth. 3 Clean all reflector surfaces with a damp cloth. 1 EngliSh 4 Remove the protective screen in front of the UV light bulb. To remove the screen, gently lift it up (1) and pull it out (2). Remove the UV light bulb. To remove the light bulb, grasp it and pull it out of the metal clasp. 6 Clean the protective screen and the UV light bulb with a damp cloth. 7 Reinsert the UV light bulb. To reinsert the light bulb, align the bottom of the light bulb with the metal clasp and push the bulb into the clasp. Reinsert the protective screen. To reinsert the screen, align the pegs on the screen with the slots on the reflective surface near the UV light bulb.Then insert the pegs into the slots and slide down the screen to secure it in the sanitizer. Storage If you are not going to use the product for an extended period of time, unplug it from the electrical outlet, clean it and store it in a cool and dry place away from direct sunlight.You can use the cord wrap to store the power cord in an organized manner. You can store brush heads on the pegs at the back of the charger. replacement Brush head Replace Sonicare brush heads every 3 months to achieve optimal results. Use only Sonicare ProResults replacement brush heads. UV light bulb Replacement UV bulbs are available through your Sonicare Customer Service Center in North America by calling 1-800-682-7664. Outside North America, contact your local Philips Customer Care Center. disposal The rechargeable battery inside your Sonicare cannot be replaced, but is easy to remove for recycling. At the end of product life and prior to disposal, please remove the rechargeable battery from the handle by following the instructions below. Do not throw away the appliance or the UV light bulb (bulb contains mercury) with the normal household waste at the end of its life, but hand it in at an official collection point for recycling. By doing this, you help to preserve the environment. If you have any recycling questions, contact your local waste management office. removing the rechargeable battery Please note that this process is not reversible. To remove the rechargeable battery, you need a flat-head (standard) screwdriver. Observe basic safety precautions when you follow the - - - - - - - - - EngliSh 13 procedure outlined below. Be sure to protect your eyes, hands, fingers, and the surface on which you work. 1 To deplete the rechargeable battery of any charge, remove the handle from the charger, turn on the Sonicare and let it run until it stops. Repeat this step until you can no longer switch on the Sonicare. Insert a screwdriver into the slot located at the bottom of the handle and turn counterclockwise to release the bottom cap. 3 Hold the handle upside down and push down on the shaft to release the internal components of the handle. 4 Insert the screwdriver under the circuit board, next to the battery connections, and twist to break the connections. Remove the circuit board and pry the battery from the plastic carrier. The rechargeable battery can now be recycled and the rest of the product discarded appropriately. guarantee and service If you have any questions after reading this manual, feel free to contact our Customer Service Center or visit our website. Customer Service Center 1-800-682-7664 (North America), outside North America contact your local Philips Customer Care Center. Internet information: (North America) or com (outside North America) See separate Philips worldwide guarantee leaflet for standard guarantee. WarranTY EXClUSiOnS What is not covered under warranty: Brush heads Damage caused by misuse, abuse, neglect, alterations or unauthorized repair. Normal wear and tear, including chips, scratches, abrasions, discoloration or fading. UV light bulb iMPliEd WarranTiES ANY IMPLIED WARRANTIES, INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL BE LIMITED TO THE DURATION OF THE -- - - 14 EngliSh EXPRESS WARRANTIES SET FORTH IN THE PHILIPS WORLDWIDE GUARANTEE LEAFLET. SOME STATES DO NOT ALLOW LIMITATION ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. liMiTaTiOn OF rEMEdiES IN NO EVENT SHALL PHILIPS OR ANY OF ITS AFFILIATED OR SUBSIDIARY COMPANIES BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES BASED UPON BREACH OF WARRANTY, BREACH OF CONTRACT, NEGLIGENCE,TORT, OR ANY OTHER LEGAL THEORY. SUCH DAMAGES INCLUDE,WITHOUT LIMITATION, LOSS OF SAVINGS OR REVENUE; LOSS OF PROFIT; LOSS OF USE;THE CLAIMS OF THIRD PARTIES INCLUDING,WITHOUT LIMITATION, DENTISTS AND DENTAL HYGIENISTS;AND COST OF ANY SUBSTITUTE EQUIPMENT OR SERVICES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR EXCLUSION MAY NOT APPLY TO YOU. EngliSh 1 Frequently asked questions This chapter lists the questions most frequently asked about the appliance. ...
Otros modelos de este manual:Cepillos de dientes - HX6902/02 (1.02 mb)
Cepillos de dientes - HX6932/10 (1.02 mb)