Iniciar sesión:
Votos - 0, Puntuación media: 0 ( )

Manual de usuario Philips, modelo HX5910/71

Fabricar: Philips
Tamaño del archivo: 523.83 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Once you reach optimal brushing power (after the 12th brushing), you will no longer hear the double beep at the beginning of your brushing routine. Note: Each of the first 12 brushings must be at least 1 minute in length to properly move through the Easy-start ramp-up cycle. To deactivate or activate the Easy-star t feature: 1 2 3 Attach your brush head to the handle. Place the handle in a plugged-in charger base. To deactivate the Easy-start feature, press and hold the power button for 5 seconds.You will hear 1 beep to indicate that the Easy-start feature has been deactivated. 10 EngliSh 4 To activate the Easy-start feature, press and hold the power button for 5 seconds.You will hear 2 beeps to indicate that the Easy-start feature has been activated. Using the Easy-start feature beyond the initial ramp-up period is not recommended and reduces the effectiveness of your Sonicare toothbrush in removing plaque. The Easy-start feature should be deactivated and the handle fully charged when Sonicare is used in clinical trials. Smartimer 2-minute timer All Sonicare models come with the Smartimer feature, , which automatically sets the brushing time to the 2 minutes recommended by dental professionals. After 2 minutes the Smartimer will automatically turn off , the toothbrush. If you wish to pause or stop brushing during your , 2-minute cycle, press the power button. Press the power button again and the Smartimer will pick up where you left off. The Smartimer will automatically reset to the beginning of , a 2-minute cycle if: -brushing is paused for 30 seconds or longer ; -the handle is returned to the charger base. Quadpacer 30-second interval timer (available on select models). Quadpacer makes sure that you brush all sections of your , mouth evenly and thoroughly. At 30, 60 and 90 seconds, you will hear a short beep and a pause in brushing action. This is your signal to move to the next section of your mouth. Battery charge indicator (available on select models). If your Sonicare has a low charge, you will hear 5 beeps , after you have brushed your teeth for 2 minutes and the charge indicator light will flash rapidly. When you hear the low charge indication, you have 3 or fewer 2-minute brushings left. 1 Place the handle in the charger base (with the power button facing towards you) to begin the recharging process. The charge indicator light flashes slowly when the handle , is in the charger base to signal charging is in progress. When the Sonicare is fully charged, the charge indicator , light is constantly on (not flashing), signaling that your Sonicare is ready for use. When not in use, keep your Sonicare in the charger base to maintain a full batter y charge. EngliSh 11 Cleaning By following these simple steps, you should get years of worry-free brushing: 1 Rinse brush head and bristles after each use. 2 Clean the brush head at least once per week, including under the removable nut. To remove the nut: ,Press down gently on the white area. Avoid using sharp objects to push on the seal as this may cause damage. ,Pull the nut up over the top of the brush head To replace the nut, slip the nut over the brush head shaft and pull until it clicks back on. 12 EngliSh Storage Replacement Brush head Replacing your brush head ever y 3 months is clinically proven to remove more plaque. Environment 3 Clean and dry the handle periodically. 4 Clean the charger base periodically. UNPLUG the charger before cleaning. After cleaning the charger base, completely dry the charger before plugging it into an electrical outlet. Mild soap, water and a moist cloth are recommended for cleaning your Sonicare. Additional Cleaning Tip: -The Sonicare handle is dishwasher safe. Remove the brush head and charger before placing the handle only in the top rack of dishwasher. -NOTE: Brush heads and charger base should never be placed in the dishwasher. If the product is not to be used for an extended period of time it should be unplugged from the electrical outlet, cleaned, stored in a cool and dr y area away from direct sunlight. The cord wrap can be used to store power cord in an organized manner. HANDLE CONTAINS NICKEL METAL HYDRIDE BATTERIES. BATTERIES MUST BE RECYCLED OR DISPOSED OF PROPERLY. -The rechargeable batter y inside your Sonicare cannot be replaced, but is easy to remove for recycling. At the end of product life and prior to disposal, please remove the rechargeable batter y from the handle by following the instructions below. EngliSh 13 -Do not throw away the appliance with the normal household waste at the end of its life, but hand it in at an official collection point for recycling. By doing this, you help to preser ve the environment. -If you have any recycling questions, contact your local waste management office. Removing the batteries Please note that this process is NOT reversible. To remove the batteries yourself, you will need a flat- head (standard) screwdriver and a small towel. Basic safety precautions should be obser ...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría