Iniciar sesión:
Votos - 2, Puntuación media: 4 ( )

Manual de usuario Crown Boiler, modelo CLBR68-112L

Fabricar: Crown Boiler
Tamaño del archivo: 219.07 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


(For counterflow / horizontal units, refer to the section of the furnace instruction manual entitled “Horizontal / Counterflow Furnace Setup”) Figure 2: Installing and Securing the Oil Burner to the Furnace Mounting Plate Only qualified service personnel shall perform installation and service. 5 8) The burner and wiring harness are equipped with mating, three (3) pole, quickconnect, electrical couplings. To make the connection between the burner wiring harness and the furnace wiring harness, open the burner junction box cover (the oil primary control serves as the cover) and remove a knockout slug from the right-hand side of the burner junction box. 9) Insert the electrical coupling from the furnace wiring harness through the knockout hole in the burner junction box. Snap together the furnace electrical coupling with the oil burner electrical coupling, refer to Figure 3. Figure 3: Connecting the Furnace Wiring Harness to the Burner Wiring Harness Only qualified service personnel shall perform installation and service. NOTICE: On the horizontal / counterflow furnace wiring harness, remove the lock-ring from the end of the flexible metal conduit connector BEFORE connecting the electrical couplings. 10)On the highboy and lowboy furnace wiring harnesses, snap the strain relief fitting into the knockout opening in the burner junction box. On the horizontal / counterflow furnace wiring harness, insert the conduit fitting through the knockout opening in the burner junction box and thread on the lock-ring from the inside of the junction box. Tighten the lock-ring until it is snug. 11)Close and secure the junction box cover on the burner. The oil burner provided with this furnace requires additional installation, set-up, and proper adjustment. Refer to the furnace instruction manual and the oil burner manufacturer’s operating instructions for detailed information on the following items. • Completion of fuel line connections to burner • Initial firing of burner • Adjusting the fuel pump pressure • Setting the draft control • Adjusting the burner combustion air 6 ...

Otros modelos de este manual:
Greeley - CHB68-112L (219.07 kb)
Greeley - CHC68-96L (219.07 kb)
Greeley - CLBF68-112L (219.07 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría