Iniciar sesión:
Votos - 4, Puntuación media: 3.5 ( )

Manual de usuario Quantum, modelo 3316

Fabricar: Quantum
Tamaño del archivo: 720.73 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


The light will flash after coming upon an obstruction in the up or down direction to warn you of a problem. It will continue flashing for 4 minutes, and then shut off. If the light begins to flash and the door moves a short distance and then reverses from a wall station button, transmitter or keyless entry, the external safety sensor device is activated or defective. To temporarily override and close door, activate wall station up/down button, keeping button depressed; opener will begin in down direction. The button must remain depressed until cycle is completed. If the button is release before cycle is completed, the door will reverse and come to full up position. Problems in the safety system should be inspected by a professional garage door installer. HOW TO OPERATE THE WIRELESS KEYLESS ENTRY (if Included) 1. Enter the 5-digit PIN number assigned to the door. Door will move. 2. Unit remains active for 25 seconds. Pressing any key will stop the door if opening and stop or reverse the door if closing. NOTE: If an error is made entering codes, simply press and hold both the “7/8 and 9/0 buttons for two seconds. The Keyless Entry will reset. 24 HOW TO OPERATE THE WIRELESS WALL STATION (If Included) Never let children operate or play with door controls. Keep remote control away from children. The Wireless Wall Station Provides the Following Features: 1. Momentarily pressing the UP/DOWN button activates the door. An open door will close and a closed door will open. 2. Momentarily pressing the LIGHT button will toggle the overhead light on and off. The light will remain on until it is turned off by another LIGHT button press or the door is activated. The overhead light turns on automatically with door activation and will turn off automatically after a 4 minute delay. 3. Momentarily pressing the Timer button activates a 10 second exit delay. The overhead light will flash on and off for 10 seconds. After the 10 second delay the door will close. The exit delay feature works only when the door is in the up position. 4. Pressing the PET LOCK button opens a closed door to a preset position between eight and thirty inches above the floor, allowing pets to enter and exit the garage without the door being fully open. The door must be fully closed to activate the pet open feature. Pressing the PET LOCK button while the door is in the pet position will cause the door to close. Pressing the UP/DOWN button while the door is in the pet position will cause the door to open. NOTE: a door in the pet position is not locked and should not be used as a secured door position. 5. The wall station PROGRAM button has several functions. a. It can be used to set a custom pet position. (see below) b. It can be used to set the opener’s closing force (See Adjustment #1 Page 21). To set a custom pet position, start with the door in the closed position. 1. Operate the door then stop it at the desired height. If desired height is not achieved, the door must be returned to the closed position. 2. Press the wall station PROGRAM button until the LED turns on solid (5 sec.), or the opener power head PROGRAM SWITCH button two times. The STATUS light on the power head unit and the overhead light will flash on and off at a normal rate. 3. Press the PET POSITION button. The STATUS light on the power head and the overhead light will flash on and off three times indicating successful programming. OPENER POWER HEAD CONTROLS The PROGRAM SWITCH located in the opener power head has several functions. 1. Pressing the PROGRAM SWITCH button once, will make the STATUS light and overhead lamp turn on solid. This mode allows programming of Transmitters, Wireless Keyless Entry, and Wireless Wall Stations (see pages 14, 17, and 20). 2. Pressing the PROGRAM SWITCH button two times will make the STATUS light and overhead lamp blink on and off. This mode allows programming of a custom pet position (see above). 3. Pressing the PROGRAM SWITCH button three times will make the STATUS light and overhead lamp blink on and off with a long pause at each blink cycle. This mode allows programming of the opening force (see page 21). 4. Pressing and holding the PROGRAM SWITCH button for 10 seconds will erase all transmitters from memory. The STATUS light and overhead light will flash 3 times indicating a successful erase operation. 25 HOW TO OPERATE THE DOOR MANUALLY – Emergency Release Disconnect The door should be fully closed if possible, weak or broken springs could allow an open door to fall rapidly. Property damage or serious personal injury could result. Do not use the manual release knob to pull the door open or closed. Do not stand near or in the path of door when using the emergency release disconnect. The opener is equipped with an emergency release recessed trolley-type disconnect system, enabling manual operation of the garage door during power failure. The trolley is disconnected from the chain by pulling down on the red release knob, allowing the garage door to be...

Otros modelos de este manual:
La puerta automática - 3214 (720.73 kb)
La puerta automática - 3414 (720.73 kb)
La puerta automática - 3314 (720.73 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría