Iniciar sesión:
Votos - 3, Puntuación media: 4.3 ( )

Manual de usuario Vista, modelo 20SE

Fabricar: Vista
Tamaño del archivo: 111.46 kb
Nombre del archivo: 2dce50ef-9af5-439e-9cb9-8b30c18aeedf.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


VISTA-20SE 2-PARTITIONED SECURITY SYSTEM PROGRAMMING FORM ® Principal changes between the VISTA-20SE and the former VISTA-20 are indicated by margin lines. VISTA-20PRV4 8/97 (See Instructions N7526V4) Local programming requires the use of a 2-line Alpha keypad connected to partition 1 keypad terminals on the control. NOTE: For UL installations, the system may be configured as a single partition only. Field Function Programmed Values [ ] = Default Value SYSTEM SETUP (*20–*29) *20 INSTALLER CODE | | | [4 1 1 2] Enter 4 digits, 0–9 *21 QUICK ARM ENABLEPart. 1† [0] Part.2† 0 = no; 1 = yes *22 RF SYSTEM [0] 0 = none; 1 = 5800 (5881/5882) *23 FORCED BYPASS [0] [0] Part. 1† Part. 2† 0 = none; 1 = bypass open zones “0”. for UL installations. *24 RF HOUSE ID CODE | [0][0] 00 = disable all wireless keypad usage; 01–31 = using 5827 keypad; Partition 2 RF House ID = Partition 1 House ID +1 *25 WIRED ZONE EXPANSION † [0] 0 = none; 1 = 4219; 2 = 4229; 3 = 4204 *26 CHIME BY ZONE † [0] 0 = no; 1 = yes (program zones to chime on zone list 3) *27 X–10 HOUSE CODE [0] 0 = A; 1 = B, 2 = C, 3 = D, 4 = E, 5 = F, 6 = G, 7 = H, 8 = I, 9 = J, #10 = K, #11 = L, #12 = M, #13 = N, #14 = O, #15 = P *28 PHONE MODULE ACCESS CODE | [00] (Partition 1 only) 1st digit: enter 1–9; 2nd digit: enter # + 11 for "* ", or # + 12 for "#". Entering 0 for either digit disables code. *29 OUTPUT TO LONG RANGE RADIO [0] 0 = disable; enable = Trouble code 1–9, B (# +11), C (# + 12), D (# + 13), E (# + 14), or F (# + 15). The 2nd digit of Trouble Dialer Report is automatically entered from field * 60. “0” for UL installations. *31 ZONESINGLE ALARM SOUNDING/ZONE SOUNDS AND TIMING (*31–*39) † [0] 1 = yes; 0 = no; “0” for UL installations. *32 FIRE SOUNDER TIMEOUT † [0] 0 = timeout; 1 = no timeout *33 ALARM BELL TIMEOUT † [1] 0 = none; 1=4 min; 2=8 min; 3=12 min; 4 = 16 min; “1” (4 min.) minimum for UL. *34 EXIT DELAY | | [70] [70] Part. 1† Part. 2† 00-99 = exit delay time for each partition *35 ENTRY DELAY 1 (zone type 01) | | [30] [30] Part. 1 † Part. 2 † 00-99 = entry delay 1 time for each partition; 20 seconds max. for UL installations † Entry of a number other than one specified will give unpredictable results. – 2 – *36 ENTRY DELAY 2 (zone type 02) | | [60] [60] Part. 1 † Part. 2 † 00-99 = entry delay 2 time for each partition; 50 seconds max. for UL installations *37 AUDIBLE EXIT WARNING [1] [1] Part. 1 † Part. 2 † 0 = no; 1 = yes *38 CONFIRMATION OF ARMING DING [0] [0] Part. 1 † Part. 2 † 0 = no; 1 = yes (wired keypads and RF); 2 = yes, RF only † [1] *39 POWER UP IN PREVIOUS STATE 0 = no; 1 = yes; “1” for UL installations DIALER PROGRAMMING (*40–*53) In fields *40, *41, *42, enter up to the number of digits shown. Do not fill unused spaces. Enter 0–9; #+11 for '*'; #+12 for '#'; #+13 for a pause. *40 PABX ACCESS CODE | | | | | Enter 6 digits. If fewer than 6 digits are entered, exit by pressing * (and press 41, if entering next field). To clear entries from field, press *40* . *41 PRIMARY PHONE No. | | | | | | | | | | | | | | | Enter up to 16 digits; Do not fill unused spaces. If fewer than 16 digits entered, exit by pressing * (and press 42, if entering next field). To clear entries from field, press * 41* . *42 SECONDARY PHONE No. | | | | | | | | | | | | | | | Enter up to 16 digits; Do not fill unused spaces. If fewer than 16 digits entered, exit by pressing * (and press 43, if entering next field). To clear entries from field, press *42* . For fields *43 - *46: *43 PRIMARY SUBS ACCT # (Part. 1) | | | Enter 0–9; #+11 for B; #+12 for C; #+13 for D; #+14 for E; [#+15 for F]. Enter * as *44 SECONDARY SUBS ACCT # (Part. 1) | | | 4th digit, if 3+1 dialer reporting is to be used. If only 3 digits used, exit by pressing *45 PRIMARY SUBS ACCT # (Part. 2) | | | | | | * (and press next field). To clear entries from field, press *43* *46 SECONDARY SUBS ACCT # (Part. 2) ,*44*, *45*, or *46* .Examples: For Acct. 1234, enter: NOTE: If using the paging feature, do not enter a leading 0 in the subscriber account number, and do For Acct. B234, enter: not use digits A-F anywhere in the number. Some For Acct. 123, enter: paging systems provide voice mail capability, which is activated by a leading 0 in the message. 1 | 2 | 3 | 4 #+11| 2 | 3 | 4 1 | 2 | 3 | * *47 PHONE SYSTEM SELECT † [1] If Cent. Sta. IS NOTon a WATS line: 0 = Pulse Dial; 1 = Tone Dial; if Cent. Sta. IS on a WATS line: 2 = Pulse Dial ; 3 = Tone Dial. *48 REPORT FORMAT [7] [0] Primary Secondary 0 = 3+1, 4+1 ADEMCO L/S STANDARD 6 or undefined = 4+2 ADEMCO EXPRESS 1 = 3+1, 4+1 RADIONICS STANDARD 7 = ADEMCO CONTACT ID REPORTING 2 = 4+2 ADEMCO L/S STANDARD 8 = 3+1, 4+1 ADEMCO L/S EXPANDED 3 = 4+2 RADIONICS STANDARD 9 = 3+1, 4+1 RADIONICS EXPANDED † Entry of a number other than one specified will give unpredictable results. – 3 – *49 SPLIT/DUAL REPORTING ** A 10-digit code is sent to the pager consisting of a 4-digit subscriber number, a 3-digit event code, and a 3-digit user or zone number. See Installatio...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría