Iniciar sesión:
Votos - 2, Puntuación media: 4 ( )

Manual de usuario Kathrein, modelo VGF 9030/9040

Fabricar: Kathrein
Tamaño del archivo: 6.76 mb
Nombre del archivo: 99811514.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


A wide range of settings, electronic operation and excellent technical data – at an unbeatable price/performance ratio. VGP 9033-1G/9041 – VGF 9030/9040 • Modern, monitorable compact amplifiers for interactive HFC networks • Innovative operational concept: Using electronic tuning elements, set using HTE 10 hand-held unit (fewer plug-in cards and attenuation pads required, repeatable device settings) • Integrated frequency-agile 2-pilot control in VGP 9033-1G/9041enables quick commissioning: Automatic levelling in the forward path, thus no need for time-consuming manual levelling Automatic presetting of the return path is possible • Remote configuration of all setting parameters via monitoring system (can be activated/deactivated) • High gain (up to 40 dB), variable in interstage position • Latest GaAs-MMIC technology • Very high output levels at lowest intermodulation products, even for interstage operation • Loop-through input (only for VGP 9033-1G/9041) and output splitter can be configured • De-emphasis (inverse-equalisation) insert position • Remote feeding: 7 A per input/output, local feeding: 10 A • Insert position for monitoring transponder (HMS/DOCSIS) • Test sockets on input/output and in return path amplifier • Integrated return path amplifier, settable gain • Ingress Control Switch • Aluminium die-cast housing with PG 11 connections "Plug-and-Play" redefined Electronic setting of all important parameters, automatic levelling (only for VGP 9033-1G/9041) as well as remote configuration via HMS or DOCSIS monitoring ensure the shortest start-up and maintenance times. The copy function enables one to copy all settings and transfer them to another device at the press of a button. The absence of plug-in cards for gain and slope not only accelerates start-up, but also simplifies logistics and saves warehousing costs. Another advantage during modifications: new values are taken over without any interruptions. Multimedia services remain undisturbed. Start-up without a measuring instrument – it doesn't get any easier than this Due to automatic levelling, the compact amplifiers VGP 9033/9041 can be put into operation with just a few steps: - Simply enter the desired output level for the lower and upper pilot frequency and start levelling - After a few seconds, the device automatically sets the desired values, whereby optimal technical data are continuously reached. Manual vernier adjustment is still possible at any time. - Subsequently, automatic presetting can also be effected in the return path. - For the next devices, levelling runs even more quickly. The copy function enables desired settings to be automatically incorporated. VGP 9033-1G/9041 VGF 9030/9040 Insert position for monitoring transponder (not included in delivery scope) Insert position "Forward 2" Connection socket for hand-held unit HTE 10 Insert position "Forward 1" e.g. for additional C-line pre-emphasis F-type test socket internal (-20 dB) F-type test socket internal (-20 dB) Image: VGP 9033-1G/9041 F-type broadband input for the return path with protective cap (-10 dB) Input insert position Output insert position DETAILS, ACCESSORIES, BLOCK DIAGRAM, DELIVERY STATUS Image: VGP 9033-1G/9041 Delivery status • EAC 93-1G (Order no. 24510115): Tap (3/6 dB) • EAC 90-1G (Order no. 24510116): Tap (1.5/10 dB) • EAC 94-1G (Order no. 24510114): Tap (0.8/20 dB) • ERC 22 (Order no. 24510085): C-line pre-emphasis equaliser for VGP 9041/VGF 9040 • ERZ 630 (Order no. 24510108): Equaliser 630 MHz • ERS 800 (Order no. 24510109): System equaliser 862 MHz • ERD 810 (Order no. 24510110): De-emphasis equaliser switchable, 862 MHz • ERD 813 (Order no. 24510117): De-emphasis equaliser • ERD 814 (Order no. 24510120): Attenuation pad • TVM 850/H (Order no. 26210077): Monitoring transponder HMS (5-24 MHz), frequency-agile • TVM 1000 (Order no. 26210086): Monitoring transponder DOCSIS • FUN 15 (Order no. 25010017): FUN remote-feed fuse 15A/125 VDC • HTE 10 (Order no. 25010005): Hand-held unit For details see pages 16-20 • Note: The input and output plug-in positions must each be equipped with a EBC/EAC xx for operation. The other plug-in positions are already equipped with null cards • Input and output cable fittings not included in the delivery scope (see page 20) • Please note that the VGF 9030/9040 does not include remote-feed fuses in its delivery scope (see page 20) Accessories • EBC 01E-1G (Order no. 24510121): Null card input • EBC 00-1G (Order no. 24510119): Null card output, for operation with one output • EBC 90-1G (Order no. 24510113): Splitter (2 outputs symmetrical) VGP 9033-1G/9041 VGF 9030/9040 DATA Technical Data Type VGF 9030 VGF 9040 VGP 9033-1G VGP 9041 Order no. 24410108 24410109 24410103 24410054 FORWARD PATH Frequency range MHz 85-862 85-862 85-1000 85-862 Gain (at 1000 MHz) dB 33 40 33 40 Return loss dB 19-1.5 dB/oct. Frequency response (85-1000 MHz at 25 °C) dB ± 0.5 Max. output level according to CENELEC 1) - CTB > 60 dB dB.V 114 Max. output ...

Otros modelos de este manual:
Avtousiliteli - VGO 939-1G/VGF 939-1G (6.76 mb)
Avtousiliteli - VGP 9033-1G/9041 (6.76 mb)
Avtousiliteli - VOS 952-1G/953-1G (6.76 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría