|
Resumen del manual
You can schedule start and stop times for each feature. All Features are operated using Flow control. The Feature mode and Filter mode are run simultaneously. The three types of features are; Features 1 & 2, Features 3 -9 and M.O. Flo: Features 1 and 2 Feature 1 and Feature 2 run for a pre-defined duration with a specifically set flow. If Feature 1 or Feature 2 buttons are pressed, all other Features are temporarily deactivated. Feature 1 or Feature 2 cannot be used in Backwash Mode. Features 1 and 2 have a higher priority than the pre-programmed Features 3-9. After the preset duration time for the Feature 1(2), IntelliFlo will switch back to the “Filter” mode if the IntelliFlo was in “Filter” mode when the Feature 1 (2) button had been pressed. After the preset duration time for the Feature 1(2), the IntelliFlo will switch back to the “Manual” mode if IntelliFlo was in “Manual” mode when the Feature 1 (2) button had been pressed. Features 3 -9 Features 3 through 9 are only active in Filter mode. These features run a set flow for a specified time. The Features 3-9 can not overlap. M. O. Flo The M. O. Flo feature automatically increases the pump flow to allow the system heater to check the water temperature and switch on if necessary. This feature is only active when the pump is running a filter cycle. Once the heater checks for heat and discovers it must fire it will send a signal back to IntelliFlo to go into “Heater” mode. M.O. Flo only works during the “Filter” mode selected time cycles IntelliFlo Installation and User’s Guide Features Mode (Continued) Feature Settings Name Value Description F1-9 and M.O. Flo Set Flow 15-130 GPM (Default 50 GPM) Pre-set flow for feature 1 -10 F3-10: Activate Feature Enabled / Disabled (Default Disabled) If value in line 1 is set Enabled the Feature will be active. If value in line 1 is set Disabled the Feature will be turned off. F1-2: Duration Time 0-10 Hours (Defualt 00:01) The time duration for feature 1 and 2. The duration must be selected for Feature 1 and 2. F3: Start time 12:00 AM -11:59 PM (Defualt 06:00 am) Start time for feature 3 F3: Stop time 12:00 AM -11:59 PM (Defualt 06:10 am) Stop time for feature 3 F4: Start time 12:00 AM -11:59 PM (Defualt 06:20 am) Start time for feature 4 F4: Stop time 12:00 AM -11:59 PM (Defualt 06:30 am) Stop time for feature 4 F5: Start time 12:00 AM -11:59 PM (Defualt 06:40 am) Start time for feature 5 F5: Stop time 12:00 AM -11:59 PM (Defualt 06:50 am) Stop time for feature 5 F6: Start time 12:00 AM -11:59 PM (Defualt 07:00 am) Start time for feature 6 F6: Stop time 12:00 AM -11:59 PM (Defualt 07:10 am) Stop time for feature 6 F7: Start time 12:00 AM -11:59 PM (Defualt 07:20 am) Start time for feature 7 F7: Stop time 12:00 AM -11:59 PM (Defualt 07:30 am) Stop time for feature 7 F8: Start time 12:00 AM -11:59 PM (Defualt 07:40 am) Start time for feature 8 F8: Stop time 12:00 AM -11:59 PM (Defualt 07:50 am) Stop time for feature 8 F9: Start time 12:00 AM -11:59 PM (Defualt 08:00 am) Start time for feature 9 F9: Stop time 12:00 AM -11:59 PM (Defualt 08:10 am) Stop time for feature 9 F10: M.O.Flo Run time 0-10 minutes (Default 1 min) "Run time" is the time for which the M.O.Flo function is running at the set flow F10: M.O.Flo Interval time 0 -255 minutes (Default 60 min) "Interval time" is the time between activation of the "set flow" value for M.O.Flo IntelliFlo Installation and User’s Guide 25 IntelliFlo Installation and User’s Guide Features Mode (Continued) The functions of the Features groups are shown below: How to set up the Feature 1 or 2 (Flow and Duration) mode To access the Features menu: 1. Ensure that the green power LED is on and the pump is stopped. 2. Press the Menu button. Press the Up or Down arrows to select the “Features” menu. Press the Select button to access the Feature 1 menu settings. The Features 1 menu setting is displayed. 3. To set the flow rate for Feature 1 or 2: Press the Select button to access the Feature 1 “Set Flow” setting. To edit the flow rate (GPM) setting, see step 6. 4. To set the duration for Feature 1 or 2: Press the Select button to access the Feature 1 “Duration” setting. To edit the time (hours and minutes) setting, see step 6. 5. Press the Select button to change the current value of Feature 1 or 2. 6. To change the value, press the Left and Right arrows to select which digit to modify, then use the Up and Down arrows to change the selected digit. 7. When you are done, press the Enter button to save the changes. To cancel any changes, press the Escape button to exit edit mode without saving. Feature Groups Features 3-9 Flow, Start / Stop Time Features 1-2 Flow and Duration MOFlo Flow, Interval, Length of Interval Filter Vacuum Back Wash Manual Enter Select Feature Reset 2 Feature 1 Menu Escape On Warn. Alarm IntelliFlo® MENU 12:45 Features Start Stop Set Flow Feature 1 displays Filter Vacuum Back Wash Manual Enter Select Feature Reset 2 Feature 1 Menu Escape On Warn. Alarm IntelliFlo® F...
Otros modelos de este manual:Piscinas - IntelliComm (6.8 mb)