Iniciar sesión:
Votos - 3, Puntuación media: 4.3 ( )

Manual de usuario Raypak, modelo 402B

Fabricar: Raypak
Tamaño del archivo: 211.31 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Job:_ Hi Delta® - Type P Engineer:--Commercial Pool Heaters Contractor:--Models 302B & 402B Prepared By:_ Date:_ Model:_ Indoor/Outdoor:_ MBTUH Input:_ Sealed Combustion Chamber 100% Factory Fire Tested Efficiency: 85% Minimum Non-condensing Inlet Temperature: 105°F Thermal Shock Proof Heat Exchanger Limited Twenty-year Thermal Shock Warranty Limited Five-year Heat Exchanger Warranty Diagnostic Center with Fault History PolyTuf Powder Coated Cabinet No Combustible Floor Shield Required Fan-assisted Non-ferrous Bypass Patented Burner Security Blanket Heat Exchanger Bronze Headers ASME Inspected and Stamped 160 PSIG Working Pressure National Board Approved Cupro Nickel Finned Tubing ASME Steel Tube Sheet Silicone High Temp O-Rings 125 PSIG ASME Pressure Relief Valve Temperature and Pressure Gauge Water Connections □ Left - Standard □ Right - Option A-6 ■ Bronze Pump, 1/3 HP, 120V, 60Hz ■ Non-Ferrous Pool Bypass Assembly with Automatic Control Controls 120V, 60Hz, 10 Power Supply 120/24V 60Hz Transformer 100% Shut-off/Lockout Hot Surface Ignition Remote Flame Sensor High Limit Control, Auto Reset On/Off Power Switch Manual Shut-off, Front-mounted Flow Switch Blocked Vent Pressure Switch Combustion Air Proving Switch Economaster Pump Time Delay Poolstat Gas Train ■ Gas Pressure Regulator ■ Safety Shut-off Valve ■ Firing Control Valve ■ On/Off Firing ■ Fuel □ Natural Gas □ Propane Gas ■ Design Certified ANSI Z21.56/ CSA 4.7 Burner ■ Ultra-low NOx: Less Than 30 PPM Construction ■ Indoor/Outdoor Construction ■ Enclosed Front Controls Venting ■ Vent Location □ Top - Standard □ Rear - Option D-14 ■ Vent Termination Cap □ Outdoor - Option D-11 □ Indoor, Horizontal -Option D-15 □ Indoor, Vertical (by others) ■ Combustion Air □ In-Line Filter Kit (TruSeal only) - Option D-17 □ Air Intake Elbow -Option D-16 Options □ C-6 □ D-21 □ F-10 □ I-1 □ S-1 □ S-2 □ X-1 □ X-2 □_ Ignition Module, Manual Reset TruSeal™ Direct Vent Low Water Cut-Off, Remote Probe High Limit Control, Auto Reset Low Gas Pressure Switch, Manual High Gas Pressure Switch, Manual SureRack™ Kit SureRack Add-on Regulatory Agency Requirements □ G-1 CSD-1 A Rhasm'Company Catalog No.: 6000.312D Effective: 8-15-08 Replaces: 2-1-08 Hi Delta - Type P Models 302B & 402B Model FRONT VIEW BACK VIEW ...

Otros modelos de este manual:
Piscinas - 302B (211.31 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría