Iniciar sesión:
Votos - 5, Puntuación media: 4.2 ( )

Manual de usuario Five Star, modelo JHP, JHPU

Fabricar: Five Star
Tamaño del archivo: 926.86 kb
Nombre del archivo: Stealth-manual.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Improper in stal la tion and/or op er a tion can create dangerous electrical hazards which can cause high voltages to run through the electrical system, possibly causing death, serious injury or property damage. Improper in stal la tion and/or op er a tion will void the warranty. ATTENTION INSTALLER: This manual contains important information about the in stal la tion, operation and safe use of this product. This information should be given to the owner/operator of this equipment. H0573800B Page 3 Table of Contents Section 1. Important Safety Instructions ........... 4 1.1 Safety Instructions .......................... 4 1.2 Pool Pump Suction Entrapment Prevention Guidelines ..................... 6 Section 2. General Description .......................... 8 2.1 Introduction ..................................... 8 2.2 Description ...................................... 8 Section 3. Installation Information .................... 8 3.1 Plumbing ......................................... 8 3.1.2 Pump Location ................................ 8 3.1.3 Pipe Sizing ...................................... 9 3.2 Electrical Installation ...................... 10 3.2.1 Voltage Checks................................ 10 3.2.2 Bonding and Grounding .................. 10 3.2.3 Electrical Wiring ............................. 10 3.3 Pressure Testing .............................. 11 Section 4. Operation .......................................... 11 4.1 Start-up ............................................ 11 Section 5. Service and Maintenance ................. 12 5.1 Routine Maintenance ...................... 12 5.2 Winterizing the Pump ..................... 12 Section 6. Troubleshooting and Repair ............. 13 6.1 Troubleshooting .............................. 13 6.2 Service Technician Maintenance .... 14 6.2.1 Blocked Impeller ............................. 14 6.2.2 Impeller Removal ........................... 14 6.2.3 Impeller Replacement ..................... 15 6.2.4 Mechanical Seal Replacement ........ 16 6.2.5 Motor Replacement ......................... 17 Section 7. Product Specifi cations and Technical Data .................................................. 18 7.1 Replacement Parts List ................... 18 7.2 Exploded View ................................ 19 7.3 SHPF and SHPM Pump Curves ...... 20 7.4 Physical and Operational Specifi cations .................................. 21 7.5 Replacement Motor Guide .............. 22 EQUIPMENT INFORMATION RECORD DATE OF INSTALLATION INSTALLER INFORMATION INITIAL PRESSURE GAUGE READING (WITH CLEAN FILTER) PUMP MODEL HORSEPOWER NOTES: Page 4 Section 1. Important Safety Instructions READ AND FOLLOW ALL INSTRUCTIONS 1.1 Safety Instructions All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes. When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: WARNING RISK OF SUCTION ENTRAPMENT HAZARD, WHICH, IF NOT AVOIDED CAN RESULT IN SERIOUS INJURY OR DEATH. Do not block pump suction as this can cause severe injury or death. Do not use this pump for wading or shallow pools or spas containing bottom drains, unless the pump is connected to at least two functioning suction outlets. Drain covers must be certified to ANSI/ASME A112.19.8. WARNING To reduce the risk of injury, do not permit children to use this product. WARNING To reduce the risk of property damage or injury, do not attempt to change the backwash (multiport, slide, or full flow) valve position with the pump running. WARNING The Jandy® Pumps are powered by a high voltage electric motor and must be installed by a licensed or certified electrician or a qualified swimming pool service tech ni cian. WARNING Due to the potential risk of fire, electric shock, or injuries to persons, Jandy® Pumps must be installed in accordance with the National Electric Code, all local electrical and safety codes, and the Occupational Safety and Health Act (OSHA). Copies of the National Electrical Code may be ordered from the National Fire Protection Association, 470 Atlantic Ave., Boston, MA 02210, or contact your local government inspection agency. WARNING Incorrectly installed equipment may fail, causing severe injury or property damage. WARNING • Do not connect system to an unregulated city water system or other external source of pressurized water producing pressures greater than 35 PSI. • Trapped air in system can cause the filter lid to be blown off which can result in death, serious personal injury, or property damage. Be sure all air is out of system before operating. Page 5 WARNING To minimize risk of severe injury or death the filter and/or pump should not be subjected to the piping system pressurization test. Local codes may require the pool piping system to be subjected to a pressure test. These requirements are generally not intended to apply to the pool equipment such as filters or pumps. Jandy® pool...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría