|
Resumen del manual
-When reinstalling Drain Pan, make sure Drain Hose is placed back in pan. 5. CHECK AFTER CLEANING -Plug unit back in. -Check that the unit is operating properly. 8 Turbo air BASIC OPERATION REFRIGERATORS 1. The controller(thermostat) is located at the back right inside of the unit. 2. The factory setting maintains about 38°F(3°C) inside. 3. Set toward “counter clock wise” warmer temperature and “clock wise” for colder temperature. Temperature Controller (Thermostat) 4. The thermostat controls compressor’s cycling by sensing inside temperature. 5. When unit will not be used for a long time, unplug the unit. 9 Turbo air BEFORE REQUESTING SERVICE SYMPTOMS CAUSES SOLUTIONS Cooler is freezing products • Thermostat set too cold. • Turn the temperature dial to a warmer setting. The unit does not refrigerate at all. • There is a power connection failure problem. • Check the power cord to make sure the unit is pluged in it correctly. The unit does not refrigerate well. • The unit is in sunlight or near a heating device. • Product was put in warm. • The unit door is opened too frequently or left open too long. • The temp. dial is not on the correct position. • The condenser is clogged. • Move out of sunlight or away from heater. • Check the condition of stored food. • Check the position of the temp control dial. There is a loud noise. • The floor is too weak or the leveling feet are set incorrectly. • The backside of the unit is too close to the wall. • Check the installation. There are dew-drops on the unit exterior. • High-moisture air can produce dewdrops during rainy seasons. • Wipe with a dry cloth. There are dew-drops on the unit interior. • The door is opened too frequently or left open too long. • Keep the door closed to remove dewdrops. The following points are not malfunctions: • A water-flowing sound can be heard when the compressor stops. This is the sound of REFRIGERANT flowing. • The compressor does not run during the defrost cycle. 10 Turbo air Warranty Warranty Claims All claims for labor or parts must be made directly through Turbo Air. If unit was manufactured more than one year, proof of purchase must be faxed in or sent with claim. All claims should include: model number of the unit, the serial number of the cabinet, and all pertinent information supporting the existence of the alleged defect. If compressor is replaced under warranty, Turbo Air will either request the compressor or compressor tag be returned. Compressor or tag must be returned with all information related to the unit. Any action or breach of these warranty provisions must be commenced within one year after said cause of action has occurred. One Year Parts & Labor Warranty Turbo Air warrants to the original purchaser of every new Turbo Air refrigerated unit, the cabinet and all parts thereof, to be free from defects in material or workmanship, under normal and proper use and maintenance service as specified by Turbo Air and upon proper installation and start-up in accord...
Otros modelos de este manual:Dispensers - TBB-1SB (203.34 kb)
Dispensers - TBB-1SB (203.34 kb)
Dispensers - TBD-1SB (203.34 kb)
Dispensers - TBD-1SD (203.34 kb)