Iniciar sesión:
Votos - 3, Puntuación media: 3.3 ( )

Manual de usuario Aga Ranges, modelo 6WCA

Fabricar: Aga Ranges
Tamaño del archivo: 774.34 kb
Nombre del archivo: d68491da-41ff-4988-916d-7405be984d36.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Important Keep your carton packaging until your wine chiller has been thoroughly inspected and found to be in good condition. If there is damage, the packaging will be needed as proof of damage in transit. Installing Your Refrigerated Wine Cooler Select Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Cabinet Clearance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Electrical Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Grounding Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Operation Set the Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Loading Tips and Suggestions . . . . . . . . . . . . . . . . . . . . .4 Inserting Wine Bottles . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Appliance Features AdjustableTemperature Control . . . . . . . . . . . . . . . . . .5 Interior Light Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Roll-outRacks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 SingleBottleRacks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Cleaning and Maintaining Your Wine Cooler Condenser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Interior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Glass Door . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Door Gasket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Light Tube Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Troubleshooting In the Event of a Power Failure . . . . . . . . . . . . . . . . . . . .7 Help Prevent Tragedies . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Important Safety Issue . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 If You Need Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Aga Customer Care For Your Records . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Warranty Information Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 All specifications and product design subject to change without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, replacements or compensation for previously purchased products. Select Location The proper location will ensure peak performance of your appliance. Choose a location where the unit will be out of direct sunlight and away from heat sources. Best performance will be maintained when installed within the following parameters: A gap of 24in (606mm) is recommended between units for moving the wine chiller. A clearance of 3in (76mm) is required to the side of the unit that the hinges are located on to allow for the door to open 90° degrees. Please see diagram for recommendations for built in applications. Cabinet Clearance Adjacent cabinets and countertop can be installed on top, back and sides of the unit as long as the grille and door access remain unobstructed. Ventilation is required for the bottom front section of the unit where the grille is located. Keep this area open and clear of any obstructions. Make certain that the leveling legs supplied with the wine cooler are installed according to the instructions. Leveling adjustments can be made by raising or lowering the glides on the bottom of the unit. Electrical Connection Use nominal 115 volt, 60 cycle AC only. DO NOT USE AN EXTENSION CORD Grounding Method This product is factory equipped with a power supply cord that has a three-pronged grounded plug. It must be plugged into a mating grounding type receptacle in accordance with the National Electrical Code and applicable local codes and ordinances. If the circuit does not have a grounding type receptacle, it is the responsibility and obligation of the customer to exchange the existing receptacle in accordance with the National Electrical Code and applicable local codes and ordinances. The third ground prong should not, under any circumstances, be cut or removed. All U.L. listed refrigerated products are equipped with this type of plug. Installing Your Refrigerated Wine Cooler All specifications and product design subject to change without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, replacements or compensation for previously purchased products. 3 Ideal Ambient Temperature Range Built-in 65° – 80°F Free-Standing 65° – 90°F. wall structure adjacent cabinet left hand swing right hand swing 3“/76mm 24” 24” DISCONNECT POWER SOURCE BEFORE ADJUSTING LEVELING LEGS THIS UNIT SHOULD NOT, UNDER ANY CIRCUMSTANCES, BE UNGROUNDED. ...

Otros modelos de este manual:
Dispensers - 115V (774.34 kb)
Dispensers - 6WCA (774.34 kb)
Dispensers - 115V (774.34 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría