Iniciar sesión:
Votos - 2, Puntuación media: 4.5 ( )

Manual de usuario Enerco, modelo UNVENTED NATURAL GAS FIRED ROOM HEATER HSIR20NGT

Fabricar: Enerco
Tamaño del archivo: 6.32 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


A. This appliance has a pilot that must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call you gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you can not reach your gas supplier, call the fire department. Open Equipment Shutoff Valve Closed Control Valve Gas Meter Equipment Shutoff Valve C. Use only your hand to push in or turn the gas control knob. Never use tools. If knob will not push in or turn by hand, don’t try to repair it; call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been underwater. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system which has been underwater. LIGHTING INSTRUCTIONS 1. STOP! Read the all safety information included with and on the side of heater. 2. Check that gas supply to heater is on. 3. Push in gas control knob and slightly turn clockwise to the OFF position (see figure 16). Note: Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly. Do not force. 4. Wait five (5) minutes. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above. If you do not smell gas, go to the next step. 5. Push in gas control knob slightly and turn counterclockwise to PILOT/IGN and depress for five (5) seconds. Note: The first time that the heater is operated after connecting the gas supply, the control knob should be depressed for about 30 seconds. This will allow air to bleed from the gas system. 6. Push in control knob and rotate control knob back to OFF position then rotate counterclockwise to PILOT/IGN position. This will light pilot. If needed gently keep rotating control knob back and forth while depressed until pilot lights. 7. Keep control knob depressed in for ten (10) seconds after lighting pilot. If pilot goes out, repeat steps 4, 5, 6 and 7. • If pilot does not stay lit, refer to Troubleshooting, pages 14 & 15. Also, contact a qualified service person or gas supplier for repairs. • If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs. 8. FOR IR10NG: When the pilot is lit, turn the control knob to “LO” position to light heater. Leave on “LO” position until first burner tile has turned bright red (Figure 18) FOR BF6NG and BF10NG: When the pilot is lit, turn the control knob to “HI” position to light heater. 9. FOR IR10NG: After first burner tile has turned bright red, adjust heat output by turning control knob to desired position (“LO” or “HI”). Do not operate heater between locked positions. FOR BF6NG and BF10NG: After flame is established (see Burner Flame Pattern, Page 12) on “HI”, adjust heat output by turning control knob to desired position (“LO” or “HI”). Do not operate heater between locked positions. Figure 16 Figure 17 CAUTION: Do not try to adjust heating level by using equipment shutoff valve. Control Knob Control Knob Burner tile pattern for IR only. LOW HIGH OFF Figure 18 WARNING: When running heater, set control knob at “LO” or “HI” locked positions. Poor combustion and higher levels of carbon monoxide may result if heater is operated with control knob positioned between locked positions. IMPORTANT: Release downward pressure while turning control knob. Control knob must be locked at the desired position. TO TURN OFF GAS TO APPLIANCE SHUTTING OFF HEATER: 1. Turn control knob clockwise to the OFF position. 2. Turn off all electrical power to the appliance if servicing is to be preformed. 3. Turn off equipment shutoff valve. SHUTTING OFF BURNER ONLY (PILOT STAYS LIT) 1. Turn control knob clockwise to the PILOT/IGN position. OPERATING YOUR HEATER THERMOSTAT MODELS IR20NGT, IR30NGT, BF20NGT, BF30NGT, TSIR20NGT, TSIR-30NGT, BF20NGT, BF30NGT FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by pushing the ignitor button. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call you gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you can not reach your gas ...

Otros modelos de este manual:
Los calentadores de gas - UNVENTED NATURAL GAS FIRED ROOM HEATER HSBF10NG (6.32 mb)
Los calentadores de gas - UNVENTED NATURAL GAS FIRED ROOM HEATER HSIR10NG (6.32 mb)
Los calentadores de gas - UNVENTED NATURAL GAS FIRED ROOM HEATER MHBF10NG (6.32 mb)
Los calentadores de gas - UNVENTED NATURAL GAS FIRED ROOM HEATER MHBF6NG (6.32 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría