Iniciar sesión:
Votos - 3, Puntuación media: 4 ( )

Manual de usuario Heat & Glo LifeStyle, modelo 8000TV-OAK-IPI

Fabricar: Heat & Glo LifeStyle
Tamaño del archivo: 2.4 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


D. DO NOT use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. For use with natural gas and propane. A conversion kit, as supplied by the manufacturer, shall be used to convert this appliance to the alternate fuel. Also Certified for Installation in a Bedroom or a Bedsitting Room. For assistance or additional information, consult a qualifi ed installer, service agency or the gas supplier. CAUTION:WARNING: Final inspection by 1. Turn off all electric power to the appliance if service is to be performed. 2. Open control access panel. 3. Move switch to “OFF” position. 4. Push in gas control knob slightly and turn clockwise to OFF”. DO NOT force. 5. Close control access panel. 1. Open control access panel. 2. Turn off all electric power to the appliance. 3. Push in gas control knob slightly and turn clockwise to “OFF”. Note: Knob cannot be turned from “PILOT” to “OFF” unless knob is pushed in slightly. DO NOT force. 4. Open the fixed glass assembly. You may need to remove the decorative front. 5. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the Safety Information located on the left side of this label. If you don’t smell gas, go to next step. 6. Find the pilot. The pilot is inside combustion chamber next to the main burner 7. Turn knob on gas control counterclockwise to “PILOT”. 8. Push in control knob all the way and hold in. Immediately depress red or black piezo button. It may require several depressions of the red or black piezo button until PILOT lights. If PILOT light does not light after 10 seconds, return to step 3. Continue to hold the control knob in for about one minute after the pilot is lit. Release knob and it will pop back out. Pilot should remain lit. If it goes out, repeat steps 3 through 6. • If knob does not pop up when released, stop and immediately call your service technician or gas supplier. • If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier. 9. Reinstall fixed glass assembly. Reinstall decorative front. 10. Turn gas control knob counterclockwise to “ON”. Close access panel. 11. Turn on all electric power to the appliance. 12. To light burner, turn the wall control or on/off switch to “ON”. LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE 464-903H Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. N • 11/08 L. After Fireplace is Lit Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • Turn the fireplace off and allow it to completely cool. • Remove fixed glass assembly. See Section 14.H. • Clean fixed glass assembly. See Section 3. • Replace the fixed glass assembly and run continuously on high an additional 12 hours. This cures the materials used to manufacture the fireplace. NOTICE! Open windows for air circulation during fireplace break-in. • Some people may be sensitive to smoke and odors. • Smoke detectors may activate. M. Frequently Asked Questions ISSUE SOLUTIONS Condensation on the glass Blue flames Odor from appliance Film on the glass Metallic noise Is it normal to see the pilot fl ame burn continually? This is a result of gas combustion and temperature variations. As the appliance warms, this condensation will disappear. This is a result of normal operation and the flames will begin to yellow as the appliance is allowed to burn for 20 to 40 minutes. When first operated, this appliance may release an odor for the first several hours. This is caused by the curing of the paint and the burning off of any oils remaining from manufacturing. Odor may also be released from finishing materials and adhesives used around the appliance. This is a normal result of the curing process of the paint and logs. Glass should be cleaned within 3 to 4 hours of initial burning to remove deposits left by oils from the manufacturing process. A non-abrasive cleaner such as gas fireplace glass cleaner may be necessary. See your dealer. Noise is caused by metal expanding and contracting as it heats up and cools down, similar to the sound produced by a furnace or heating duct. This noise does not affect the operation or longevity of the appliance. In an Intellifire ignition system it is normal to see the pilot flame, but it should turn off when ON/OFF is turned off. In a standing pilot system the pilot will always stay on. Heat & Glo • 8000TV-OAK, 8000TV-OAK-IPI, 8000TVLP-OAKIPI • 2058-900 Rev. N • 11/08 3 33 Maintenance and Service Any safety screen or guard removed for servicing must be replaced prior to operating the fireplace. When properly maintained, your fireplace will give you many years of trouble-free service. We recommend annual service by a qualified service technician. A. Maintenance Tasks-Ho...

Otros modelos de este manual:
Los calentadores de gas - 8000TV-OAK (2.4 mb)
Los calentadores de gas - 8000TVLP-OAKIPI (2.4 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría