|
Resumen del manual
The 585A/YACR is the natural or propane model supplied with the RELITE-type pilot that saves gas by operating only when the wall thermostat calls for heating. The 586A/YACX is the deluxe model with RELITE-type pilot and many value added features for reliability and performance. These units are designed for outdoor installation either on a rooftop or at ground level on a slab. The cooling section is factory-charged and sealed, minimizing installation time. Installation is easy—connect gas supply, air ducts, condensate drain, high- and low-voltage wiring, and install the air filter. A full line of rooftop system accessories are available for field installation. These accessories include plenums with factory-supplied high-capacity filter and outside air intake hood, unitized curbs, economizers (both plenum-installed and horizontal), barometric relief dampers, concentric diffuser box assemblies, flexible duct packages, and high-ca-pacity filter racks with filters. When installing these accessories, see installation instruction packaged with them. Important—Read Before Installing 1. Check all local or other applicable codes for information concerning proximity to property lines, height above roof, obstructions, etc. 2. Make certain power supply available (volts, hertz, and phase) corresponds to that specified on unit rating plate. 3. Check electrical supply provided by utility to be sure that service capacity is sufficient to handle load imposed by this unit. 4. Locate the unit where the vent cap is a minimum of 4 feet from openable windows or doors. 5. The installation must conform with local building codes or, in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1. GENERAL The condensing section has been designed and tested in accordance with ARI 210. The appliance design is certified by American Gas Association for use with natural or propane gases with appropriate controls and orifices. Installation of the unit consists of the following: I. Moving and Setting Unit In Place II. Venting III. Gas Piping IV. Duct Connections V. Electrical Connections Cancels: New ly'/ 585А/YAC 585A/YACR 586A/YACX Sizes 018050 THRU 060150 39585DP1 1 1/1/76 m Figure 1 ■Models 585A/YAC & 585A/YACR, Sizes 048150, 0601 25, & 060150 VI. Preparing Unit for Startup VII. Heating Startup and Adjustments VIII. Cooling Startup and Adjustments IX. Care and Maintenance I. MOVING AND SETTING UNIT IN PLACE Extreme caution should be used to prevent damage when moving the unit. The unit should remain in an upright position during all rigging and moving operations, lb facilitate lifting and moving, place the unit in an adequate rope or cable sling. CAUTION: Be sure to protect the top and sides of the unit when rigging the unit to be lifted. See Figure 4. A. Rooftop Installation Place the unit on a level base that is at least 6 inches above the roof to prevent flooding. Consult local codes for installation requirements. Be sure the roof will support the additional weight. NOTE: See the installation instructions packaged with the accessory plenum and unitized curb when these system accessories are being installed. B. Ground Level Installation Place the unit on a level concrete slab with a minimum of 4 inches thickness. CAUTION: Unit must be mounted level for proper condensate drainage. C. Clearances The minimum clearance is 6 inches from the duct side, 24 inches from the condenser coil side, and 30 inches from the remaining two sides of the unit to allow for adequate service space. Minimum clearance from the top is 24 inches. BDP Company, Division of Carrier Corp. DIMENSIONS (Inches) Size A B D E F G H J 018050 & 024055 44-5/8 30-3/8 16 10 — 1-1/8 16 7-1/4 024080, 030080, & 036080 44-5/8 40-3/8 19 10 1-3/8 13-1/4 8-7/8 036100, 036125, 042100, 042125, & 048125 58-5/8 44-5/8 24 14 1-3/8 13-1/4 8-7/8 048150, 060125, & 060150 66-7/8 44-5/8 32 10 15-3/4 1-3/8 13-1/4 8-7/8 ELECTRICAL DISCONNECT MAY BE MOUNTED ON THIS PANEL *-18- >\ 8 — SUPPLY AIR RETURN AIR 2: •-E-* t-tf-- I*—F—J REAR VIEW Le— 8 Figure 2 —Dimensional Drawing for Models 585A/YAC, 585A/YACR, & 586A/YACX TABLE I—RATING, PERFORMANCE, & FILTERS MODEL 585A/YAC, 585A/YACR, & 586A/YACX SIZE 018050 024055 024080 030080 036080 036100 036125 042100 042125 048125 048150 060125 060150 Rated Cooling Capacity (Btuh)* 18,500 23,000 24,000 29,000 37,000 35,500 35,500 42,000 42,000 47,000 47,000 59,000 59,000 Heating Input (Btuh)t 50,000 55,000 80,000 80,000 80,000 100,000 125,000 100,000 125,000 125,000 150,000 125,000 150,000 Heating Bonnet Capacity (Btuh)t 37,500 41,250 60,000 60,000 60,000 75,000 93,750 75,000 93,750 93,750 112,500 93,750 112,500 Temperature Rise Range (°F) 45-75 45-75 45-75 45-75 45-75 45-75 45-75 45-75 45-75 45-75 45-75 45-75 45-75 Cooling Airflow (CFM)* 690 850 900 1000 1200 1300 1300 1550 1550 1600 1600 2200 2200 Ext Static Press. (In. wc) (1)* 0.4/0.8 0.4/0.8 0.4/0.8 0.4/0.8 0.4/0.8 0....
Otros modelos de este manual:Los calentadores de gas - 586A/YACX (1.39 mb)
Los calentadores de gas - 585A/YACR (1.39 mb)