The unit will run on natural gas or LP gas, but it has been factory set to run on natural gas. Section 1 — General Information Bryant Air-cooled 7 kW, 12 kW and 15 kW Generators Should the primary fuel need to be changed to LP gas, the fuel system needs to be reconfigured. See Section 1.9 for instructions on reconfiguration of the fuel system. Recommended fuels should have a Btu content of at least 1,000 Btus per cubic foot for natural gas; or at least 2,520 Btus per cubic foot for LP gas. Ask t
The requirement is limited to 15 and 20 ampere, 125 volt circuits. There is no prohibition against providing AFCI protection on other circuits or in locations other than bedrooms. Because circuits are often shared between a bedroom and other areas such as closets and hallways, providing AFCI protection on the complete circuit would comply with 210.12. If during the installation of the Bryant Home Standby system the decision is made to provide back up power to a bedroom branch circuit, then the c
VOLTAGE REGULATOR TYPE ................................................................................................................Electronic SENSING ....................................................................................................Single Phase REGULATION ..........................................................................................................± 1% FEATURES................................................................................................V/F Adj
Overhead Valve Push Rod Hydraulic Lifter GOVERNOR SPECIFICATIONS TYPE ................................................................................................................Electronic FREQUENCY REGULATION ......................................................................Isochronous STEADY STATE REGULATION ............................................................................± .25% ENGINE LUBRICATION SYSTEM OIL PUMP ..............................................................
or in life-support applications. DANGER DEADLY EXHAUST FUMES. OUTDOOR INSTALLATION ONLY! INTRODUCTION Thank you for purchasing this model of the Bryant product line. This model is a compact, high performance, air-cooled, engine-driven generator designed to automatically supply electrical power to operate critical loads during a utility power failure. This unit is factory installed in an all-weather, metal enclosure that is intended exclusively for outdoor installation. This generator will operat
The battery is capable of exploding. A battery presents a risk of electrical shock and high short circuit current. The following precautions are to be observed when working on batteries: • Remove the 7.5A and 15A fuses from the generator control panel. • Remove watches, rings or other metal objects; • Use tools with insulated handles; • Wear rubber gloves and boots; • Do not lay tools or metal parts on top of the battery; and • Disconnect charging source prior to connecting or disconnecting batt
Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose BRYANT with the confidence that these systems will provide superior performance. .. TEST CRITERIA: .. PROTOTYPE TESTED .. SYSTEM TORSIONAL TESTED .. NEMA MG1-22 EVALUATION .. MOTOR STARTING ABILITY .. SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regula
Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose CARRIER with the confidence that these systems will provide superior performance. TEST CRITERIA: > PROTOTYPE TESTED • • SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Bryant models. It provides optimized FAST RESPONSE
! ONLY QUALIFIED ELECTRICIANS OR CONTRACTORS SHOULD ATTEMPT INSTALLATION!! DEADLY EXHAUST FUMES. OUTDOOR INSTALLATION ONLY! This manual should remain with the unit. INTRODUCTION Thank you for purchasing a Bryant home standby generator system. Every effort was expended to make sure that the information and instructions in this manual are both accurate and current at the time the manual was written. However, the manufacturer reserves the right to change, alter or otherwise improve this product(s)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Rated Horsepower................................................................................. 14.5 @ 3,600 rpm . . . . . . . . . . . . . . . . .30 @ 3,600 rpm . . . . . . . . . . . . . . . . . .30 @ 3,600 rpm Displacement................................................................................................... 410cc . . . . . . . . . . . . . . . . . . . . . . . . .