Manual de usuario Enerco, modelo TSBF10LP

Fabricar: Enerco
Tamaño del archivo: 998.73 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


The hardware package is provided with heater. Installation instructions and Owner’s Manual 70575 Rev. C 8/05 6 1. Drill holes at marked locations using 5/16” drill bit. For solid walls (concrete or masonry), drill at least 1” deep. 2. Fold wall anchor as shown in figure 8 below. Figure 8. 3. Insert wall anchor (wings first) into hole. Tap anchor flush to wall. 4. For thin walls (1/2” or less) insert red key into wall anchor. 5. Place mounting bracket onto wall. Line up holes on each end of bracket with wall anchors. 6. Insert mounting screws through bracket and into wall anchors. 7. Tighten screws until mounting bracket is firmly fastened to wall. Placing Heater on Mounting Bracket 1. Locate two horizontal slots on back pane of heater (see figure 19). 2. Place heater onto mounting bracket. Slide horizontal slots onto stand-out tabs on mounting bracket. Horizontal Slots Mounting Bracket mounted to wall Figure 9 Installing Bottom Mounting Screws 1. Locate two bottom mounting holes. These holes are near bottom on back panel of heater (see figure 10). Figure 10 2. Mark screws locations on wall. 3. Remove heater from mounting bracket. 4. If installing bottom mounting screw into hollow or solid wall, install wall anchors. Follow steps 1 through 4 under Attaching to Wall using Anchor. If installing bottom mounting screw into wall stud, drill holes at marked locations using 9/64” drill bit. 5. Re-place heater onto mounting bracket. 6. Place spacers between bottom mounting holes and wall anchor or drilled hole. 7. Hold spacer in place with one hand. With the other hand, insert mounting screw through bottom mounting hole and spacer. Place tip of screw in opening of wall anchor or drilled hole. 8. Tighten both screws until heater is firmly secured to wall. Do not over tighten. Note: Do not re-place front panel at this time. Replace front panel after making gas connections and checking for leaks. FLOOR MOUNTING AWAY FROM WALL: Figure 11 Installing Support Feet (see figure 11) 1. Lay heater onto table on its back with bottom edge overhanging table edge. 2. Securely attach feet to bottom of heater using 2 – self-tapping screws each. Note: Feet should have long end going out the front of heater, and the edge coinciding with side of heater. If feet overhang side of the heater, switch leg location. 3. Place heater on non-combustible surface (see Locating Heater above) before proceeding with gas connection. If this will be a permanent location, heater may be locked into position using anchoring holes in mounting feet. Note: Use of floor mounting feet will require you to use a 3/8 NPT street elbow to make gas connection. CONNECTING TO GAS SUPPLY WARNING: A qualified service person must connect heater to gas supply. Follow all local codes. 7 Installation instructions and Owner’s Manual WARNING: This appliance requires a 3/8” NPT (National Pipe Thread) inlet connection to the pressure regulator. Use of floor mounting feet will require you to use a 3/8 NPT street elbow to make gas connection. WARNING: This appliance requires a 3/8” NPT (National Pipe Thread) inlet connection to the pressure regulator. Use of floor mounting feet will require you to use a 3/8 NPT street elbow to make gas connection. CAUTION: Never connect heater directly to the Propane supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and Propane/LP supply. Install sediment trap in supply line as shown in figure 12. Locate sediment trap where it is within reach for cleaning. A sediment trap traps moisture and contaminants. This keeps them from going into heater. If sediment trap is not installed or is installed improperly, heater may not run correctly. IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/or fittings. CHECKING GAS CONNECTIONS 8 The installer must supply an external regulator. The external regulator will reduce the incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 12. Pointing the vent down protects it from freezing rain or sleet. CAUTION: Use only new black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of larger enough diameter to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur. Installation must include an equipment shutoff valve, union and plugged 1/8” NPT tap. Locate NPT tap within reach of test gauge hookup. NPT tap must be upstream from heater (see figure 12). Figure 12 *A CSA/AGA certified equipment shutoff valve with 1/8” NPT tap is an acceptable alternative to test gauge connection. Purchase the CSA/AGA certified equipment shutoff valve from your dealer. See Accessories, page 17. IMPORTANT: Install an equipment shutoff valve in an accessible location. The equipment shutoff ...

Otros modelos de este manual:
Eléctrico - MHBF10LP (998.73 kb)
Eléctrico - TSBF20LPT (998.73 kb)
Eléctrico - TSBF30LPT (998.73 kb)
Eléctrico - MHBF20LPT (998.73 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría