Iniciar sesión:
Votos - 2, Puntuación media: 4.5 ( )

Manual de usuario Enerco, modelo TSBF20LPT

Fabricar: Enerco
Tamaño del archivo: 998.73 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


2). You can also remove door into adjoining WARNING: If the area in which the heater may be operated in smaller that that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by on the methods described in the National Fuel Gas Code, NFPA 54/ ANSI Z223.1, Section 5.3 or applicable local codes. 3. Add the Btu/hr of all the fuel-burning appliances in the space such as, Vent–free heater, Gas water heater, Gas furnace, Vented gas heater, Gas fireplace logs, and Other gas appliances* *Do not include direct-vent gas appliances. Direct- vent draws combustion air from the outdoors and vents to the outdoors. Example: Gas water heater 40,000 Btu/hr Vent Free Heater + 20,000 Btu/hr Total =60,000 Btu/hr 4. Compare the maximum Btu/hr the space can support with the actual amount of Btu/hr used. Example: 51,800 Btu/hr (maximum Btu/hr the space can support) 60,000 Btu/hr (Actual amount of Btu/hr used) The space in the above example is a confined space because the actual Btu/hr used is more than the maximum Btu/hr the space can support. room (see option3, fig 2). Follow the National Fuel Gas Code NFPA 54/ ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts. Figure 2 WARNING: Rework worksheet, adding the space of the adjoining unconfined space. The combined space must have enough fresh air to supply all appliance in both spaces. Ventilation Gills into Adjoining Room - Option 1 Ventilation Gills into Adjoining Room - Option 2 12” 12” Or remove door into Adjoining Room - Option 3 4 Installation instructions and Owner’s Manual 70575 Rev. C 8/05 NOTICE: This heater is intended for the use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source for the duration of the outage. WARNING: A qualified service person must install heater. Follow all local codes. CHECK GAS TYPE Use only LP-gas. If your gas supply is not LP-gas, do not install heater. Call dealer where you bought heater for proper type heater. THIS INSTALLATION REQUIRES: Before installing heater, make sure you have the items listed below: •Piping (check local codes) •Sealant (resistant to LP_Gas) •Ground joint union •Test gauge connection* •Sediment trap •Tee joint •Pipe wrench *A CSA/AGA certified equipment shutoff valve with 1/8” NPT tap is an acceptable alternative to test gauge connection. Purchase a CSA/AGA certified equipment shutoff valve from your dealer. See Accessories, page 17. LOCATING HEATER This heater is designed to be mounted on the wall. The heater can also be located on a non-combustible floor, away from a wall by using the floor mounting stands included with the heater. If installed on combustible flooring such as carpeting, tile or other combustible material other than wood flooring, the heater must be placed on a wood panel the full width and depth of the appliance. For convenience and efficiency, install the heater: •Where there is easy access for operation, inspection, and service. •In the coldest part of the room. •If planning to use fan, locate heater near an electrical outlet. CAUTION: If you install the heater in a home garage: •Heater pilot and burner must be at least 18 inches above floor. •Locate heater where moving vehicle will not hit it. CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall covering or operating heater where impurities (such as tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) are present in the air may discolor walls. WARNING: Never install the heater: • In a bathroom. • In a bedroom (IR20LPT, IR30LPT, BF20LPT or BF30LPT) • In a recreational vehicle. •Where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top, or sides of the heater. • As a fireplace insert • In high-traffic areas • In windy or drafty areas WARNING: Heater must be mounted to maintain the minimum clearances shown in Figure 4. If possible, provide greater clearances from the floor, ceiling, and joining walls. VENTILATED OUTLET AIR NOTICE: This heater is intended for the use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source for the duration of the outage. WARNING: A qualified service person must install heater. Follow all l...

Otros modelos de este manual:
Eléctrico - MHBF10LP (998.73 kb)
Eléctrico - TSBF10LP (998.73 kb)
Eléctrico - TSBF30LPT (998.73 kb)
Eléctrico - MHBF20LPT (998.73 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría