Iniciar sesión:
Votos - 2, Puntuación media: 3.5 ( )

Manual de usuario Empire Comfort Systems, modelo 5088-3

Fabricar: Empire Comfort Systems
Tamaño del archivo: 162.09 kb
Nombre del archivo: 8629b13b-7139-469d-b9ee-00cae409c299.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


— WHATTO DO IFYOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. — Installation and service must be performed by a qualified installer, service agency or the gas supplier. WARNING: If not installed, operated and maintained in accordance with the manufacturer's instructions, this product could expose you to substances in fuel or from fuel combustion which can cause death or serious illness. R-1842 Page 1 Introduction Always consult your local Building Department regarding regulations, codes or ordinances which apply to the installation of a floor furnace. Instructions to Installer 1. Installer must leave instruction manual with owner after installation. 2. Installer must have owner fill out and mail warranty card supplied with furnace. 3. Installer should show owner how to start and operate furnace and thermostat. Warning: Any change to this furnace or its control can be dangerous. This is a heating appliance and any panel, door or guard removed for servicing an appliance must be replaced prior to operating the appliance. General Information This series is design certified in accordance with American National Standard Z21.86b-1998 by the Canadian Standards Association Laboratories as a gravity type Floor Furnace and must be installed according to these instructions. Any alteration of the original design, installed other than as shown in these instructions or use with a type of gas not shown on the rating plate is the responsibility of the person and company making the change. Qualified Installing Agency The installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1. Important All correspondence should refer to complete Model Number, Serial Number and type of gas. Notice: During initial firing of this furnace, its paint will bake out and smoke will occur. To prevent triggering of smoke alarms, ventilate the room in which the furnace is installed. Specifications Models 3588 5088 7088 Input BTU/HR 32,500 45,000 65,000 Dimensions Register Length &Width 34 3/4" x 22 3/4" 36 3/4" x 24 3/4" 36 3/4" x 32 3/4" Casing Length & Width 32" x 20" 34" x 22" 34" x 30" Overall Length Including Diverter 40" 43 1/2" 45 1/4" Floor Opening, Length & Width 32 5/16" x 20 5/16" 345/16" x 22 5/16" 34 5/16" x 30 5/16" Height 23" 26" 27" Minimum Clearance to Combustibles Top Must Be Open and Clear of ALL OBJECTS and Covering Each Side to Nearest Wall 6" 6" 6" Bottom of Unit for Air 6" 6" 6" Draft Diverter and Vent Connector 6" 6" 6" Two Adjoining Sides to Walls to Provide a Walkway 18" 18" 18" Gas Inlet Iron pipe Size (N.P.T.) 1/2" 1/2" 1/2" Inlet to Floor 18 1/2" 20 1/4" 20 1/4" Venting Floor to Top of Diverter Shield 10 1/2" 12 3/4" 12 3/4" Center of Flue (Horizontal) to Floor Covering 17 1/4" 18 3/4" 17 3/4" Size of Flue Collar 4" Dia. 4" Dia. 5" Dia. The flue pipe diameter must be as large as the flue collar on the draft diverter and run as directly as possible to the chimney at least 1/4" rise per foot of run properly supported by metal straps, and enter the chimney so the end of the flue pipe is flush with the inner wall of the chimney. Any flue pipe passing through walls and roof must be "B" type vent. The chimney must extend at least two feet above the roof and any object or building within 10 feet of the chimney. The flue pipe must NOT have any open tees or be connected to the chimney of an existing fireplace. THIS IS A HEATING APPLIANCE DO NOT OPERATE THIS APPLIANCE WITHOUT FLOOR REGISTER INSTALLED • Due to high temperatures the appliance should be located is imperative that control compartments, burners and out of traffic and away from furniture and draperies. circulating air passageways of the appliance be kept clean. • Children and adults should be alerted to the hazards of high surface temperatures and should stay away to • DO NOT use this heater if any part has been under avoid burns or clothing ignition. water. Immediately call a qualified service technician to inspect the heater and to replace any part of the control • Young children should be carefully supervised when system and any gas control which has been under water. they are in the same room as the appliance. • Floor furnace must not be connected to a chimney flue • Clothing or other flammable material should not be serving a separate solid fuel burning appliance. placed on or near the appliance. • The draft hood shall be installed so as to be in the same • Any safety screen or guard removed for servicing an atmospheric pressure zone as the combustion air inlet to appliance must be replaced prior to operating the the appliance. appliance. • A burn hazard can occur in the use of the floor furnace • Installation and repair should be done by a QUALIFIED when th...

Otros modelos de este manual:
Eléctrico - 7088-3 (162.09 kb)
Eléctrico - 3588-3 (162.09 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría