Manual de usuario Empire Comfort Systems, modelo FAW-55SPP

Fabricar: Empire Comfort Systems
Tamaño del archivo: 805.78 kb
Nombre del archivo: 624958d1-47de-472d-943d-b5a2769b49bb.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Listed gas vent equipment. Installing Optional Side Outlets Side outlet register, SOR-1 may be installed on one or both sides of the furnace at the required clearances of 18 inches (457mm) to adjacent wall or combustible material as shown in Figure 2. 1. Locate and cut the 5 1/2” (140mm) square opening in the cabinet side using the template from the kit, exposing the inner liner knockout. 2. Remove the knock-out. 3. Place the register on the 5 1/2” (140mm) opening with the louvers set for the desired direction and mark the mounting holes using the register as a template. 4. Drill two (2) 1/8” (3mm) diameter holes in cabinet side and fasten the register in place with two (2) #10 x 1” (25mm) screws provided. Side outlet kit, 10” (254mm) boot assembly with register, SOK-1 for warm air discharge into an adjoining room may be installed on either side of the furnace at the required clearance of 4 inches (102mm) to adjacent wall as shown in Figure 3A. 1. Locate and cut the 5 1/2” (140mm) square opening in the cabinet side using the template from the kit, exposing the inner liner knockout. 2. Remove the knock-out. 3. Using the inner and outer boots as hole templates, mark and drill (8) 1/8” (3mm) diameter holes in the inner liner and cabinet side. 4. Using Figure 3A locate and cut a 6 3/4” (171mm) square opening through walls. 5. Attach furnace to wall (see Attaching Furnace to Wall). 6. With furnace in place, after checking alignment of side outlet opening in wall and furnace, place the 9 3/8” x 9 3/8” (238mm x 238mm) side outlet wall plate over outer boot, pass the outer boot through the wall and attach side outlet wall plate to furnace side of wall with (2) #10 x 1” (25mm) screws provided. 7. Fasten outer boot to the cabinet side with (4) #8 x 1/4” (6mm) screws provided. 8. Position and attach inner boot to inner liner with (4) #8 x 1/4” (6mm) screws provided. 9. Locate the register with its louvers positioned for the desired air discharge direction and mark the mounting holes using the register as a template. 10.Drill (2) 1/8” (3mm) diameter holes in the wall and fasten the register in place with (2) #10 x 1” (25mm) screws provided. Installing Optional Rear Outlet Rear outlet kit, 10” (254mm) boot assembly with register, ROK-1 for warm air discharge into an adjoining room. Attention: Before furnace is attached to the wall, the wall opening for the rear outlet must be cut, in addition to removal of the outer and inner casing knockouts on furnace. 1. The wall opening measurements for the rear outlet are the following. A. From floor to bottom of wall opening is 14 3/4” (375mm). B. From the bottom of wall opening to top of wall opening is 8 1/2” (216mm). C. Wall opening width is 12 1/8” (308mm). 2. Remove outer casing knockout from outer casing back. 3. Remove inner casing knockout from inner casing. 4. Attach furnace to wall (see Attaching Furnace to Wall). 5. Align clearance holes on 8” x 12” (203mm x 305mm) boot with screw holes on outer casing back and mark boot to be flush with wall surface. Remove boot and cut to proper length. 6. Attach 8” x 12” (203mm x 305mm) boot to outer casing back with (6) #10 x 1/2” (13mm) screws provided. 7. Align clearance holes on 6” x 10” (152mm x 254mm) duct with screw holes on inner casing and mark duct to be 2 1/4” (57mm) shorter than 12428-3-0706 Page 4 Page 5 12428-3-0706 8” x 12” (203mm x 305mm) boot. Remove duct and cut to proper length. 8. Attach 6” x 10” (152mm x 254mm) duct to inner casing with (6) #10 x 1/2” (13mm) screws provided. 9. Insert rear register into 8” x 12” (203mm x 305mm) boot. Attach rear register to wall with (2) #10 x 1” (25mm) screws provided. Locating Furnace On Wall The furnace is to be located on a wall. The furnace is 16 inches (406mm) in width and normal 16” (406mm) on center studs will not allow the furnace to be recessed into the wall unless a stud is repositioned. A template is proved in furnace carton for locating gas line connection. Also, refer to Figure 2 for positioning the furnace on wall and for locating gas line connection. Locating Gas Supply The gas line can enter the furnace either though the floor or wall. The gas line opening should be made at this time. Location of the opening will be determined by the position of floor joists and the valve and union used for servicing. Location Electric Supply A 7/8” (22mm) diameter knockout is provided at the bottom of the left and right side panels. A three-prong (grounding) plug assembly is located within the control compartment (bottom) of the furnace. Please remove 7/8” (22mm) knockout from appropriate side panel when routing plug assembly to an electrical outlet. Installation of Three-prong (Grounding) Plug Assembly 1. Disconnect nylon cap on 3’ (914mm) plug assembly from nylon plug on wiring harness. Remove 3’ (914mm) plug assembly from control compartment (bottom) of the furnace. 2. Remove 7/8” (22mm) knockout from appropriate side panel. 3. Insert nylon cap on 3’ (914mm) plug assembly int...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría