Manual de usuario Regency, modelo Gas Insert E33-NG1

Fabricar: Regency
Tamaño del archivo: 159.47 kb
Nombre del archivo: aecd1809-97b6-4364-bd66-c592774fc029.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


(1.25 kPa) 12” W.C. (2.99 kPa) Manifold Pressure - High 3.8” W.C. (0.95 kPa) 11” W.C. (2.74 kPa) Manifold Pressure - Low 1.1” W.C. (0.27 kPa) 2.9” W.C. (0.72 kPa) Orifice Size -Altitude 0-4500 ft. #31 DMS #50 DMS Minimum Input Altitude 0-4500 ft. (0-1372m) 20,000 BTU/h (5.86 kW) 19,000 BTU/h (5.57 kW) Maximum Input Altitude 0-4500 ft. (0-1372m) 38,000 BTU/h (11.14 kW) 35,500 BTU/h (10.40 kW) Vent Sizing 3” Co-linear 3” Co-linear A C G Approved Venting Systems Flex Vent Systems: FPI AstroCap™ Flex Vent Dimension Description E33 A Faceplate Width 45-9/16” (1157mm) B Faceplate Height 31-1/8” (791mm) C Unit Width 32-1/4” (819mm) D Unit Height 23-13/16” (605mm) E Unit Depth 16-3/4” (426mm) F Faceplate to Vent Centerline 11-1/4” (286mm) G Faceplate Depth 1-3/8” (35mm) H Height to Vent Collar 23” (583mm) I Optional or Standard Front Depth N/A Minimum Fireplace Dimensions The minimum fireplace dimensions for the FPI gas fireplace insert are shown in the following diagrams: Dimension Description Contour Faceplate J Height 24-3/16” (614mm) K Width 32-1/4” (819mm) L Depth 17” (432mm) M Max. Lintel Bar Depth 8” (203mm) N Rear Width 25” (635mm) E June 2007 Regency Product Specifications Book 127 Gas Inserts Gas Inserts ^R] EGENCY Gas Inserts FIREPLACE PRODUCTS E33 Gas Insert Clearances Combustible Mantels Unless otherwise stated the clearances listed below are Minimum distances to combustible materials. Please Note: A major cause of chimney related fires is due to a failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions. Because of the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of the louvers are shown in the diagram below. Mantel may be installed anywhere in the shaded area or higher. Clearances to Combustibles Dimension Description E33 A* From Unit to Side Walls 8” (203mm) B From Unit to Ceiling 47” (1194mm) C Minimum Mantel Height 15” (381mm) D Maximum Mantel Depth 12” (305mm) E Alcove Width 76” (1930mm) F Alcove Depth 36” (914mm) G Hearth Height 1-%” (32mm) H Hearth Width 45-/” (1156mm) I Hearth Depth 13” (330mm) 12 10 8 6 * Alcove side wall must have a minimum of 8” (203mm) clearance on one side. 20 - 18 -16 - 47” I4-(1194mm) to ceiling 10 -8 6 4 -2 0- t 12" (305mm) Mantel 3-1/2" (89mm) Mantel 20” i[508mm) 15” f-(381mm) 25" (635mm) to floor Top Of Unit Side View Flush Front Mantel Clearances Mantle Faceplate Hearth 12" Max. D I ^ i Combustible _ ! Flooring Existing Hearth ■4-¡-► I 16" Min. Flush with Floor Note: A non-combustible mantel may be installed at a lower height. Note: Ensure the paint that is used on the mantel and the facing is “heat resistant” or the paint may discolour. 128 June 2007 Regency Product Specifications Book...

Otros modelos de este manual:
chimeneas - Gas Insert E33-LP1 (159.47 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría