Iniciar sesión:
Votos - 4, Puntuación media: 3.8 ( )

Manual de usuario Continental, modelo CBI 360-N

Fabricar: Continental
Tamaño del archivo: 2.3 mb
Nombre del archivo: ff97f2af-64c7-4c89-b03d-c6b892bd3d63.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


SYMPTOM PROBLEM TEST SOLUTION TROUBLE SHOOTING GUIDE BEFORE ATTEMPTING TO TROUBLESHOOT, PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR REMOVED. SYMPTOM PROBLEM TEST SOLUTION Pilot goes out when System is not correctly purged. -purge the gas line with the glass door removed. the gas knob is re- Out of propane gas. -fill the tank. leased. Pilot flame is not large enough -turn up the pilot flame. Pilot flame is not engulfing the -gently twist the pilot head to improve the flame pattern thermopile. around the thermopile. Thermopile shorting. -clean thermopile and valve connection. -check that thermopile insulation is not frayed and grounding out on the housing or the burner support. -replace thermopile. -replace valve. Faulty thermopile. -replace. Faulty valve. -replace. Pilot will not light. No spark at pilot burner -check that the wire is connected to the push button ignitor. -check if the push button ignitor needs tightening. -replace pilot assembly if the wire insulation is broken or frayed. -replace pilot assembly if the ceramic insulator is cracked or broken. -replace the push button ignitor. Spark gap is incorrect -spark gap should be 1/16" to 1/8" from the electrode tip and the pilot burner. Light the pilot with a match and adjust the electrode tip to the required spark gap and proper location. No gas at the pilot burner -check that the manual valve is turned on. -check the pilot orifice for blockage. -replace the valve. -call the gas distributor. Out of propane gas -fill the tank. Pilot goes out while Gas piping is undersized. -turn on all gas appliances and see if pilot flame flutters, standing; Main diminishes or extinguishes, especially when main burners burner is in 'OFF' po-ignite. Monitor supply pressure. sition. -check if supply piping size is to code. Correct all under sized piping. Pilot burning; no gas to main burner; gas knob is on; wall switch is on. Wall switch is defective Wall switch wiring is defective. -connect a jumper wire across the wall switch terminals; if the main burner lights, replace the wall switch. - disconnect the switch wires from the valve & connect a jumper wire across terminals 1 and 3; if the main burner lights, check the wires for defects and/or replace wires. Main burner orifice is plugged. -remove stoppage in orifice. Remote gas valve operator is defective. -connect a jumper wire across terminals 1 and 3; if main burner does not light, replace gas valve. Main burner flame is Insufficient secondary air. -increase fresh air supply (open door, window, add make-up a blue, lazy, transpar- air supply) ent flame. Downdraft or blockage in chim--remove blockage. ney. -check that chimney is installed to building codes (3ft above highest roof line or 2ft higher than any portion of a building within a horizontal radius of 10ft of the chimney.) W415-0120 / E / 01.11.05 SYMPTOM PROBLEM TEST SOLUTION SYMPTOM PROBLEM TEST SOLUTION Main burner goes out; Refer to "Main burner goes out; pilot stays on" pilot goes out. Chimney down-drafting -wait ten minutes. Shut off all exhaust fans in the house (ie: kitchen and bathrooms), furnace, and clothes dryer. Open windows and/or doors. Start fireplace and monitor its operation. Close doors and windows and start appliances as before; room is in negative pressure; increase fresh air supply. Chimney is blocked -check for chimney blockage. Liner disconnected from insert. -re-attach liner. Faulty spill switch. -replace. Main burner goes out; Pilot flame is not large enough -turn on pilot flame. Gently twist the pilot head to improve pilot stays on. or not engulfing the thermopile. the flame pattern aroung the thermopile. Thermopile shorting. -clean thermopile and thermopile connection to valve. Carbon is being de-Air shutter has become blocked -ensure air shutter opening is free of lint or other obstrucposited on glass, tions. logs or combustion Flame is impinging on the logs chamber surfaces. or combustion chamber. -check that the logs are correctly positioned. -open air shutter to increase the primary air. -check the input rate: check the manifold pressure and orifice size as specified by the rating plate values. -check that the door gasketing is not broken or missing and that the seal is tight. -check that both 4" and 7" vent liners are free of holes and well sealed at all joints. -check that minimum rise per foor has been adhered to for any horizontal venting. Remote wall switch Wall switch is mounted upside -reverse. is in off position; down. main burner comes Remote wall switch is grounding. -replace. on when gas knob is Remote wall switch wire is -check for ground (short); repair ground or replace wire. turned to "ON" posi grounding. tion. Faulty valve. -replace. Exhaust fumes Fireplace is spilling. -check for chimney blockage. smelled in room, -check that chimney is installed to building code. headaches. -room is in negative pressure; increase fresh air supply. Carbon is being de-Flame is impinging o...

Otros modelos de este manual:
chimeneas - CBI 360-P (2.3 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría