Minimum clearance to combustibles are: Appliance: side and back - 0" floor - 0" adjacent wall - 6" ceiling - 37 ... ” (953 mm) Combustible Finished Wall Materials Top of Appliance 12" (305mm) 2" (51mm) 7 ..." (286mm) 16 ..." (422mm) Top of Hood Spacer6'' (152mm) 8'' (203mm) 10'' (254mm) 14 ..." (375mm) 13" (330mm) 11 ..." (191mm) ..." GapRequired CF5500 and CF6500 Models Figure 2 A hearth extension is not required with this appliance. If a hearth extension is used, do not block the lower control compartment door. Any hearth extensions used is for appearance only and does not have to conform to standard hearth extension installation requirements. Note:Combustible wall finish materials and/or surround materials must not be allowed to encroach the area defined by the appliance front face (black sheet metal). Never allow combustible materials to be positioned in front of or overlapping the appliance front face. A combustible mantel shelf projecting a maximum of 8" (203 mm) from the wall may be installed a minimum distance of 13" (330 mm) from the top of the hood (Figure 3). 6" Clearance 37 ..." Min. to Ceiling(953 mm) (See Fig 2) to Combustible Side Wall Max. Projection (See Fig 2) Combustible Mantel Figure 3 PREINSTALLATION Check that all listed parts have been received. Carefully inspect the heater case and contents for shipping damage and immediately inform the dealer from whom you purchased the gas fireplace if any damage is found. The appliance is shipped with all gas controls and components installed and pre-wired. Remove the shipping carton, exposing the optional (if installed) front glass door frame. Remove wood slats and remove and discard the wood slat mount brackets. Loosen and remove the three (3) ... "-20 x 1" Phillips pan head screws at the three (3) tabs located along the door frame top edge. Tilt the glass door frame assembly outward and disengage the three (3) tabs along the bottom of the door from the three (3) brackets at the bottom of the firebox opening. Remove the door and set the panel aside protecting it from inadvertent damage. Retain the three (3) screws for use on reassembly. Check Gas Type This appliance can only be connected to the gas type specified on the appliance data plate. This appliance can not be modified in the field for a different gas type. If the gas type to be used is not the one specified contact the dealer to obtain the correct gas appliance. Note:Illustrations shown in this manual reflect “typical” installations with nominal dimensions and are for design and framing reference only. Actual installations may vary due to individual design preferences. However, always maintain minimum clearances to combustible materials and do not violate any specific installation requirements. NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. Note:The following steps represent the normal sequence of installation. Each installation is unique, however, and might require a different sequence. CAUTION: HEATERS CREATE WARM AIR CURRENTS. THESE CURRENTS MOVE HEAT TO WALL SURFACES NEXT TO HEATER. INSTALLING HEATER NEXT TO VINYL OR CLOTH WALL COVERINGS OR OPERATING HEATER WHERE IMPURITIES IN THE AIR (SUCH AS TOBACCO SMOKE) EXISTS, MAY DISCOLOR WALLS. Step 1. Position heater in desired location (onto surround base or into prepared framing) and secure. Step 2.Plumb gas line. (Gas connections should only be performed by an experienced, licensed/ certified tradesman.) Step 3. Assemble logs and test flame appearance. Step 4. Complete finish wall material, surround and optional hearth extension to your individual taste. INSTALLATION STEPS WARNING: DO NOT ALLOW FANS TO BLOW DIRECTLY INTO THE FI...
Otros modelos de este manual:chimeneas - STANDARD SERIES CF5500-CMN (598.98 kb)
chimeneas - STANDARD SERIES CF5500-CMN (598.98 kb)
chimeneas - STANDARD SERIES CF5500-CMN (598.98 kb)
chimeneas - STANDARD SERIES CF5500-CMN (598.98 kb)