Iniciar sesión:
Votos - 4, Puntuación media: 4.5 ( )

Manual de usuario Regency, modelo STANDARD SERIES CF5500-CMP

Fabricar: Regency
Tamaño del archivo: 598.98 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


USE CAUTION AROUND THE APPLIANCE TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE. OPERATION AND CARE OF YOUR APPLIANCE 1. Appliance operation is controlled through an on/off switch. Separate switches may provide independent control for the optional forced air kit and fireplace operation (see Optional Equipment). 2. To light the appliance refer to the lighting instructions located at the back of this manual. Note:Instructions are also found on the pullout panel located in the lower control compartment of the appliance. 3. Flame Adjustments – These appliances are equipped with a two stage, High (HI), Low (LO) gas control valve. This valve provides for easy flame height adjustment. To adjust the burner between the HI and LO settings, rotate the HI/LO knob, located in the center of the valve front face, clockwise and counterclockwise respectively. 4. When lit for the first time, the appliance will emit a slight odor for an hour or two. This is due to the “burn-in” of the internal paints and lubricants used in the manufacturing process. Additionally, when lit for the first time, this appliance may produce smoke, this is normal and should be expected. For the first few hours, operate the appliance with doors and windows open to encourage the dissipation of smoke and fumes. 5. Upon each lighting of the appliance, condensation may occur and fog the inside of the glass enclosure panel. This condition is normal and will disappear as the glass surface heats. 6. Always keep the appliance area clear and free from combustible materials, gasoline and other flammable liquids. 7. Remember, these appliances have a continuous burning pilot flame. Exercise caution when using products with combustible vapors. WARNING: OBSERVE CAUTION NEAR THE GLASS ENCLOSURE PANEL. THE GLASS MAY SHATTER UNEXPECTEDLY OR IF STRUCK WITH AN OBJECT. 8. CAUTION: DO NOT OPERATE THIS APPLIANCE WITH A BROKEN GLASS PANEL. Where broken glass exists, the complete glass enclosure panel must be replaced. See the Replacement Parts List on page 18 for correct replacement part numbers. Glass enclosure panel removal and installation instructions are described on pages 5 and 10 respectively. Maintenance Maintenance The appliance should be inspected before use and at least annually by a professional service person. Replace the catalytic component if CO levels measured at the appliance vent outlet exceed 1/1000 of 1% after (10 Min) of burning. Replacement of the catalytic component should only be completed by a qualified service person at least every 20 years. Ensure the air shutter openings are not obstructed (see Figure 22). Cleaning and Servicing WARNING: TURN OFF THE APPLIANCE AND ALLOW TO COOL BEFORE CLEAN- ING. WARNING: ALWAYS TURN OFF THE GAS SUPPLY TO THE PILOT BEFORE CLEAN- ING. BEFORE RE-LIGHTING, REFER TO THE LIGHTING INSTRUCTIONS IN THIS MANUAL. INSTRUCTIONS ARE ALSO FOUND ON THE PULL-OUT PANEL LO- CATED IN THE APPLIANCE LOWER CON- TROL COMPARTMENT. ONLY LIMITED CLEANING WILL BE REQUIRED UNDER THE NORMAL USE OF THE APPLIANCE. THE EXTERNAL CASE SHOULD BE OCCA- SIONALLY DUSTED AND WIPED WITH A DAMP SOAPY CLOTH. Clean the glass only when necessary. Wipe surface with a clean, dampened, soft cloth. Follow with a dry, soft towel as desired. Take care not to scratch the glass surface. WARNING: DO NOT USE ABRASIVE CLEANERS. NEVER CLEAN THE GLASS WHEN IT IS HOT. If, after a period of use, the flames start to exhibit unusual shapes and behavior, or the burners fail to ignite smoothly, then the burner holes may require some cleaning. If this occurs, it is preferable to contact y...

Otros modelos de este manual:
chimeneas - STANDARD SERIES CF5500-CMN (598.98 kb)
chimeneas - STANDARD SERIES CF5500-CMN (598.98 kb)
chimeneas - STANDARD SERIES CF5500-CMN (598.98 kb)
chimeneas - STANDARD SERIES CF5500-CMN (598.98 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría