|
Resumen del manual
WARNING Sharp Edges. WatchYour Fingers! WARNING: EDGES OF SHEET METAL ARE SHARP! WEAR PROTECTIVE GLOVES AND USE EXTREME CARE WHEN HANDLING. Required tools: • Sheet Metal-resistant Gloves • Tin Snips 1. Using tin snips, cut the three connecting points securing the slug to the three tabs in the flue collar (as shown in Figure 10a), and remove the slug. Carefully dispose of slug in an appropriate container. Slug Figure 10a Cutting points 2. Connect the proper size Type B-vent system tothefireplacefluecollarbybendingupthe three tabs and securing with three sheet metalscrews(No.8orlarger)benduptabs. See Figure 10b. Then install the remainder of the Type B-vent to the outside. Figure 10b Type B-Vent SLBV-35 models: 4 in. (102 mm) SLBV-40 models: 5 in. (127 mm) SUPERIORSUPERIORB-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS 10 ft. Minimum Back View Of Appliance Vertical Installations Back View Of Appliance *12 ft. Min. **15 ft. Min. *with an offset up to 45 degrees** with an offset greater than 45degrees and up to 60 degrees Offset Installations Figure 11 3. Refer to Figure 11. The following venting configurations may be installed: Vertical Installations • Minimum overall height of the vent system and appliance without an offset must be 10 ft (2.54 m). Offset Installations • Offset up to 45 degrees from vertical: Minimum overall height of the vent system and appliance must be 12 ft (3.66 m). The lower part of the offset may start at the fireplace flue collar. • Offset greater than 45 degrees and up to 60 degrees from vertical: Minimum overall height of the vent system and appliance must be 15 ft (4.57 m). The lower part of the offset may start at the fireplace flue collar. Maximum overall height of the vent system and appliance should not exceed 40 ft (12.19 m). Install the B-vent system in accordance with the vent manufacturer's instructions. CAUTION: THIS APPLIANCE CANNOT BE VENTEd HORIzONTALLY. Note: Refer to the vent manufacturers installation instructions for variations of venting techniques. If common venting of several units is contemplated, it should be discussed with an architect and the local Building Department. do not place insulation materials within 1 in. of the gas vent system. Step 4. Install field Wiring CAUTION Ground supply lead must be con nected to the wire attached to the green ground screw located on the outlet box. See Figure 13. failure to doso willresultin a potential safety hazard. The appliance must be electricallygroundedinaccordance withlocalcodesor,intheabsenceof local codes, the National Electrical Code, ANSI/NfPA 70 latest edition. (In Canada, the current CSA C22-1 Canadian Electrical Code). CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors cancauseimproperanddangerousoperation. ATTENTION : Au moment de l'entretien des commandes, etiquetez tous les fils avant de les debrancher. Des erreurs de cablage peuvent entrainer un fonctionnement inadequat et dangereu...
Otros modelos de este manual:chimeneas - SLBV-35NE (2.89 mb)
chimeneas - SLBV-35NE (2.89 mb)
chimeneas - SLBV-35NE (2.89 mb)
chimeneas - SLBV-35NE (2.89 mb)