Iniciar sesión:
Votos - 2, Puntuación media: 3.5 ( )

Manual de usuario Hearth and Home Technologies, modelo 6000GL-IPILP-R

Fabricar: Hearth and Home Technologies
Tamaño del archivo: 3.33 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


914 mm 16 ft * 4.9 m* 3 ft. 914 mm 14 ft.* 4.3 m* *H1 + H2 = 20 ft. (6.1 m) Maximum V1 + V2 + H1 + H2 = 40 ft. (12.2 m) Maximum 26 Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 Top Vent - Vertical Termination No Elbow Figure 7.6 Note: If installing a vertical vent/ termination off the top of the appliance, the fl ue restrictor should be used. V1 V1 = 40 ft. Max. (12.4 m) V1 = 3 ft. Min. (914 mm) Figure 7.8 Flue Restrictor 2. Break the fl ue restrictor into two pieces. Do this by bending the part back and forth until it breaks (see Figure 7.8). Figure 7.7 BREAK HERE EXHAUST SHIELD FLUE RESTRICTOR Flue Restrictor Instructions 1. Remove exhaust shield using a 1/4 inch nut driver by removing the four screws securing it in place (see Figure 7.7). Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 27 H1 V1 V2 Top Vent - Vertical Termination (continued) Figure 7.11 Two Elbows Figure 7.10 4. Center the Flue Restrictor on vent and secure in place by using two self-tapping screws (see Figure 7.10). 3. Match the amount of vertical you have in the system 5. Reinstall the Exhaust Shield. with the chart to fi nd the appropriate position to set the Flue Restrictor (see Figure 7.9). Figure 7.9 1 2 3 4 5 SETTING 1 2 3 4 5 Vertical TOP VENT REAR VENT NG LP NG LP 4 ft. 1-1 No Restrictor No Restrictor No Restrictor 8 ft. 2-2 1-2 1-1 No Restrictor 15 ft. 3-3 3-2 2-2 1-2 20 ft. 3-4 3-3 3-3 2-3 25 ft. 3-4 3-3 3-3 2-3 30 ft. 4-4 3-4 3-4 3-3 35 ft. 4-4 3-4 3-4 3-3 40 ft. 5-4 4-4 4-4 3-4 V1 H1 Maximum V2 V1 + V2 Min. Elbow only 2 ft. 610 mm * * * 6 in. 152 mm 6 ft. 1.8 m * * * 2 ft. 610 mm 11 ft. 3.4 m * * * 3 ft. 914 mm 16 ft. 4.9 m * * * 4 ft. 1.2 m 20 ft 6.1 m * * * V1 + V2 + H1 = 50 ft (15.2 m) Maximum *No specifi c restrictions on this value EXCEPT V1 + V2 + H1 cannot exceed 50 ft (15.2 m) Note: If the DVP-2SL or DVP-SLP24 adapter is used with SLP pipe, you MUST subtract one number from the table above. Example: Top vent 40 ft vertical with DVP pipe = 5-4 Top vent 40 ft vertical with SLP pipe = 4-3 .. 28 Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 Figure 7.12 Top Vent - Vertical Termination - (continued) Three Elbows INSTALLED HORIZONTALLY H1 H2 V1 V2 V1 H1 + H2 V2 V1 + V2 Minimum H1 + H2 Maximum Elbow only 1 ft. 305 mm * * * 1 ft. 305 mm 6 in. 152 mm 2 ft. 610 mm * * * 2 ft. 610 mm 1 ft. 305 mm 2 ft. 610 mm * * * 2 ft. 610 mm 2 ft. 610 mm 4 ft. 1.2 m * * * 4 ft. 1.2 m 3 ft. 914 mm 9 ft. 2.7 m * * * 9 ft. 2.7 m 4 ft. 1.2 m 18 ft. 5.5 m * * * 18 ft. 5.5 m H1 + H2 = 20 ft (6.1 m) Maximum V1 + V2 + H1 + H2 = 40 ft (12.2 m) Maximum Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 29 Rear Vent - Horizontal Termination Figure 7.13 Figure 7.14 No Elbow One 45. Elbow H1 H1 H1 = 16 in. (406 mm) Maximum Do not use a 45. elbow in corner installations. Use two 90. elbows instead. 30 Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 INSTALLED HORIZONTALLY H3 H1 H2 V1 Rear Vent - Horizontal Termination - (continued) Two Elbows Figure 7.15 Figure 7.16 Three Elbows H1 H2 V1 H1 Maximum V1 Minimum H2 H1 + H2 Maximum 1 ft. 305 mm Back to Back 90. Elbows 1 ft. 305 mm 2 ft. 610 mm 2 ft. 610 mm 6 in. 152 mm 2 ft. 610 mm 4 ft. 1.2 m 3 ft. 914 mm 1 ft. 305 mm 2 ft. 610 mm 5 ft. 1.5 m 3 ft. 914 mm 2 ft. 610 mm 4 ft. 1.2 m 7 ft. 2.1 m 3 ft. 914 mm 3 ft. 914 mm 9 ft. 2.7 m 12 ft. 3.7 m 3 ft. 914 mm 4 ft 1.2 m 18 ft. 5.5 m 20 ft.* 6.1 m* V1 + H1 + H2 = 40 ft (12.2 m) Maximum H1 = 3 ft (914 mm) Maximum *H1 + H2 = 20 ft (6.1 m) Maximum H1 Maximum V1 Minimum H2+ H3 H1+ H2+ H3 Max. 1 ft. 305 mm Back to Back 90. Elbows 1 ft. 305 mm 2 ft. 610 mm 2 ft. 610 mm 6 in. 152 mm 1.5 ft. 457 mm 3.5 ft. 1.1 m 3 ft. 914 mm 1 ft. 305 mm 2 ft. 610 mm 5 ft. 1.5 m 3 ft. 914 mm 2 ft. 610 mm 4 ft. 1.2 m 7 ft. 2.1 m 3 ft. 914 mm 3 ft. 914 mm 9 ft. 2.7 m 12 ft. 3.7 m 3 ft. 914 mm 4 ft. 1.2 m 12 ft. 3.7 m 15 ft. 4.6 m V1+ H1+ H2+ H3= 40 ft (12.2 m) Maximum H1= 3 ft (914 mm) Maximum H1+ H2+ H3= 20 ft (6.1 m) Maximum Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 31 Rear Vent - Vertical Termination One Elbow Figure 7.17 Two Elbows Figure 7.18 H1 V1 INSTALLED HORIZONTALLY H1 H2 V2 V1 Minimum H1 Maximum 6 in. 152 mm 2 ft. 610 mm 1 ft. 305 mm 3 ft. 914 mm 2 ft. 610 mm 5 ft. 1.5 m 3 ft. 914 mm 7 ft. 2.1 m 4 ft. 1.2 m 8 ft 2.4 m 5 ft. 1.5 m 8 ft 2.4 m V1 + H1 = 40 ft (12.2 m) Maximum H1 = 8 ft (2.4 m) Maximum H1 + H2 Maximum V1 Minimum Back to Back 90. Elbows 3 ft. 914 mm 2 ft 610 mm 6 ft. 1.8 m 4 ft 1.2 m 9 ft. 2.7 m 6 ft. 1.8 m 12 ft. 3.7 m 8 ft. 2.4 m 15 ft. 4.6 m V1 + H1 = 40 ft (12.2 m) Maximum H1 + H2 = 8 ft (2.4 m) Maximum 32 Heat & Glo • 6000GL-IPI-R, 6000GL-IPI-S • 2102-900 Rev. O • 12/08 Rear Vent - Vertical Termination - (continued) Three Elbows Figure 7.19 Three Elbows Figure 7.20 INSTALLED HORIZONTALLY H3 H1 H2 V1 V2 V1 H2 H1 H1 H2 H3 V1 Minimum H1 + H2 + H3 Maximum * * * 8 ft. 2.4 m 6 ft. 1.8 m * * * 9 ft. 2.7 m 7 ft. 2.1 m * * * 10 ft. 3.1 m 8 ft. 2.4 m * * * 10 ft....

Otros modelos de este manual:
chimeneas - 6000GL-IPI-R (3.33 mb)
chimeneas - 6000GL-IPI-S (3.33 mb)
chimeneas - 6000GL-IPILP-S (3.33 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría