Iniciar sesión:
Votos - 4, Puntuación media: 4 ( )

Manual de usuario FMI, modelo Becton Bunny

Fabricar: FMI
Tamaño del archivo: 524.86 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


See "SAFETY NOTICES" ref coal set page 4. Ensure the appliance is cold. Step 1 Isolate the gas supply to the fire using the gas cock supplied at installation. Step 2 Open the fire door, (Held closed using a magnet). Step 3 Remove the glass frame and the glass/ gasket assembly. Step 4 Carefully remove and clean the coal set of any soot deposits using a soft brush. Step 5 Carefully remove and clean the firebox linings. Where necessary. Step 6 Inspect the chimney and flue terminal ensuring they are in good working order and sweep as necessary to ensure no debris blocks the flue. Please note periodic chimney sweeping is vital to gas fire maintenance. Step 7 Remove matrix location plate and valve heat shield. Clean any soot deposits from inside the fire using a vacuum cleaner. See “Safety notes”on page 4. Step 8 Inspect the pilot assembly to ensure that it is clean, unobstructed and in good order. Step 9 Check system for gas soundness. Step 10 Replace heat shield and matrix location plate. Step 11 Replace fire box linings. Step 12 Replace coal set. Step 13 Replace glass/gasket and glass frame and close the fire door. Step 14 Carry out spillage test as per instructions on page 16. CLEANING OUTER SURFACES To clean the outside first the appliance must be cold. The outside finish of the fire is a durable high temperature paint, this will give off a slight odour during the first few days of operation. It is best cleaned by using a soft brush. Do not allow moisture to remain on the fire whilst cold or surface rust may occur. CLEANING THE GLASS To clean the glass the appliance must be cold. Step 1 Open the fire door. (This is held closed using a magnet) Step 2 Remove the glass frame and the glass/gasket assembly (See page 19). Take care not to damage the glass or gasket when cleaning. Step 3 Replace glass frame and the glass/gasket assembly. Close the fire door. Becton Bunny & Becton 7 mk3 Gas stoves SERVICING FAULT DIAGNOSIS START Does the pilot ignite? Yes Does the pilot stay alight? Yes Does the main burner light? Yes Fire satisfactory No No No Is the gas supply Is the main Is their air in the No Yes Yes turned on? injector blocked? Turn gas on system? Purge system Clean and replace as Yes No No necessary Is the supply Is the No pressure correct? thermocouple o.k.? Correct pressure Yes Yes Is their a spark at the Is pilot injector No obstructed? electrode? Check piezo igniter Yes No Check to ensure the Has spillage pilot assy is not monitoring obstructed or faulty system been activated? Yes Is the flue Carry out No blocked? smoke test Correct alignment or replace No Confirm supply Yes pressure is correct Clean No Check all pipe connections check main valve magnet Investigate flue systems Becton Bunny & Becton 7 mk3 Gas stoves SPARE PARTS GENERAL COMPONENTS Spare parts can be obtained by contacting the original supplier of the fire or Aarrow Fires. Fire Body Ancillary Components. Only use genuine Aarrow parts. ACCESSORIES AND OPTIONS Paint-Matching aerosol paint to tone in any connecting flues, pipes or surrounding metalwork Tracery or Trim - Note: When fitted one replaces the other. Add on Canopies Bunny - Low available only Size: 400mm wide x 345mm deep. Raises the stove approximately 140mm. Becton 7 - High and low are available. Size:-480mm wide x 345mm deep High. Raises the stove approximately 240mm Low. Raises the fire approximately 180mm. Becton Bunny & Becton 7 mk3 Gas stoves NOTES Becton Bunny & Becton 7 mk3 Gas stoves NOTES Becton Bunny & Becton 7 mk3 Gas stoves SPARE PARTS Part Description Visual Aid (not to scale) Bunny mk3 Part No. Becton 7 mk3 Part No. 1. Becton 7 mk3 Coal Set -AFGS1075 1a. Becton Bunny mk3 Coal Set AFGS1074 - 2. Co-pilot assembly AFGS089 AFGS089 3. Elbow Injector AFGS090 AFGS090 4. Gas Control Valve AFGS091A AFGS091 5. Magnetic Catch for mk3 Gas Fires. AFGS1073 AFGS1073 6. Hinge Kit To Fit Either Door. Comprises 2 Hinges & 4 Fixings Per Set. AFS047 AFS047 Becton Bunny & Becton 7 mk3 Gas stoves SPARE PARTS Part Description Visual Aid (not to scale) Bunny mk3 Part No. Becton 7 mk3 Part No. 7. Control Door Handle Assembly AFGS1085 AFGS1085 8. Burner & Fixing AFGS1076 AFGS1077 9. Pipe Set Complete With Connectors AFGS080 AFGS080 10. Decorative Door Surround (Trim) AFS094A AFS095 11. Fire Door Assembly complete with Magnet Lock and Trim AFGS1078 AFGS1079 12. Glass Replacement Kit with Gasket & Fixings. AFGS1080 AFGS1081 13. Hotplate AFGS064 AFGS010 14. Flue Outlet Spigot AFGS1082 AFGS1083 Becton Bunny & Becton 7 mk3 Gas stoves SPARE PARTS Part Description Visual Aid (not to scale) Bunny mk3 Part No. Becton 7 mk3 Part No. 15. Becton 7 mk3 Lining Kit -AFGS1072 16. Large Ceramic Panel AFGS093 AFGS093 17. Medium Ceramic Panel AFGS094 AFGS094 18. Small Ceramic Panel AFGS1084 AFGS1084 19. Gas Tap AFGS025 AFGS025 20. Manual AFS1125 AFS1125 21. Feet and Fixings AFS1013 AFS1013 22. Aarrow Fires Gauntlet Gloves AFS997 AFS997 Becton Bunny & Becton 7 MK3 Gas stoves GUARANTEE GUARANTEE Once again we woul...

Otros modelos de este manual:
chimeneas - Becton 7 mk3 (524.86 kb)
chimeneas - Becton 7 mk3 (524.86 kb)
chimeneas - Becton 7 mk3 (524.86 kb)
chimeneas - Becton 7 mk3 (524.86 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría