|
Resumen del manual
The factory programming has the After Hours™ mode turned OFF. The After Hours™ can be programmed to come on from 1 to 6 hours after the last brew. When the E-Max™ goes into the After Hours™ mode, any warmer plates left on will be turned off (on decanter brewers), the water in the tank will be allowed to drop from the normal brewing temperature and will re heat less frequently – this feature saves energy and extend component life. While in the After Hours mode, the power light will flash continuously. When the BREW switch is pressed the E-Max™ automatically reverts back to normal operation, heating the water to the Precise Temperature for Brewing™ (PTB™), before starting the brew. (The power light will be on continuously and the Brew light will flash until the correct water temperature is reached.) 9. Countdown Quality Timer™: Refers to coffee warmers. Not applicable to Airpot and Thermal brewers. 10. Pulse or Pre-Infusion Volume Options: To set these features, refer to E-Max™ Programming Manual, Brew Settings Menu. If a particular brew volume has utilized the pulse or pre-infusion option, that volume will be displayed with an asterisk (*) after the volume. As an example “Volume#2 64oz*” would indicate that the second programmed brew volume has utilized the pulse or pre-infusion program options. 11. Keypadlock™: This feature is OFF in the standard factory settings. To set the feature refer to E-Max™ Programming Manual, Machine Settings Menu. If the Keypadlock™ feature is activated, there will be no response by the brewer when the keys are depressed (except for the beep after a key is depressed). To temporarily “unlock” the keypad, press and hold the CANCEL key for 6 seconds. A beep will be heard indicating the keypad is now “unlocked”, — a brew can be initiated, warmer plates turned on or off, etc. The keypad will remain unlocked until the brew is completed, then automatically return to keypadlock™ mode. If a brew is not initiated 60 seconds after “unlocking”, the system will time out and return to the “locked” position. 9 OPERATION (continued) OPERATION (continued) 12. View Filter Statistics: To view filter statistics, turn the brewer off. Press and hold the 1st key (Brew), and depress the 3rd (ON/OFF) key. Total water volume will be displayed (TotalVol.). Press the 3rd key to view the Filter Life (FltrLife:). Press the 3rd key to view the percentage of the filter that has been used. (If the filter option is used, the filter life volume needs to be entered in the program – see E-Max™ Programming Manual, Service & Counters Menu.) 13. Diagnostic Messages – Programmed Safety Features: When the E-Max senses a problem, it will automatically turn off all elements and valves, flash lights, display the message “Call For Service” and display one of the messages below. (Additionally: a service phone number may appear if it has been programmed into the system.) *To reset the brewer it can be re-energized (or press and hold CANCEL for 3 seconds for all faults except the Valve Fault, which must be reset by re-energizing). The brewer will try to re-start, but if the same problem persists, the appropriate error message will appear again. Consult the Trouble Shooting section to determine how to solve the problem. A. “Probe/Heater Error”: Overheating Detection (1): If the heating element is on for 5 minutes and the temperature does not change by +2°F (1°C) in the five minute period, the unit will go into the Over Temperature Mode with all lights flashing. When in this mode the brewer turns off the heating elements, the solenoid valves are turned off; the switches disabled; (and all lights flashing continuously). The LCD display will read “Probe/Heater Error”, followed by the message “Call for Service”, and then the service phone number (if it has been entered into memory). To reset press and hold CANCEL for 3 seconds, or re-energize the brewer. (Possible causes of problem: high limit needs to be re-set; defective high limit, element, triac, water level probe or control board.) B. “Overheat Error”: Overheating Detection (2): If the E-Max™ senses a temperature over the Maximum Temperature set in the program (factory set at 208.F or 98.C) it will go into the over temperature mode as above with all lights flashing, except the LCD will read “overheat error”, and “Call for Service”. To reset press and hold CANCEL for 3 seconds, or re-energize the brewer. (Possible cause of problem is a defective triac, temperature probe or related wiring and connections.) C. “No Water Sensed” — Time-Out —Inlet Valve: When filling for the first time, the inlet valve will remain open for 4. minutes, (the screen will read “filling…”). If water is not detected at the end of this time the E-Max will shut down with the message “no water sensed”. The valves and all elements are turned off, and the Brew and Power light flash alternately with the Heat light, until the brewer is reset. To reset press and hold CANCEL for 3 seconds, or re-energize the brewer...
Otros modelos de este manual:Cafeteras - 2088 (1.27 mb)
Cafeteras - 2088EX (1.27 mb)
Cafeteras - 2082 (1.27 mb)
Cafeteras - 2086 (1.27 mb)