# NOTICE (HINWEIS)
●
# INFO
Beispiel für eine E-Mail:
----BEGINN BEISPIEL----
Subject: HP AlertMail-010: (CRITICAL) Power Supply #1: Failed
Date: Wed, 23 Apr 2003 15:02:22 +0200
From: Enclosure IA-00508BEBA571
To: Benutzer@Benutzerdomäne
X-OS: HP Integrated Administrator
X-Priority: 1
Content-Type: text/plain; charset=us-ascii
EVENT (26 May 07:09): Power Supply #1 Status has changed to: Failed
Enclosure, IA-00508BEBA571, has detected that a power supply in bay 1 has
changed from status OK to Failed.
The power supply should be replaced with the appropriate spare part. You
can ensure that the center wall assembly is operating correctly by swapping
the two power supplies. Make sure that there are no bent pins on the power
supply connectors before reinserting and that each power supply is fully
seated.
An amber LED on the power supply indicates either an over-voltage, over-
temperature, or loss of AC power event has occurred. A blinking LED on the
power supply indicates a current limit condition.
Enclosure Status: Degraded
Enclosure Management URL:
- PLEASE DO NOT REPLY TO THIS EMAIL –
----ENDE BEISPIEL----
Einrichten von IP Security
HINWEIS: Hierbei handelt es sich nicht um IPSec.
Mithilfe von IP Security kann ein Administrator die IP-Adressen festlegen, die eine Verbindung zu den
verfügbaren Diensten herstellen dürfen (SSH, HTTP, TELNET, SNMP). Das bedeutet, dass ein
Administrator sicherstellen kann, dass nur bestimmte Systeme auf Integrated Administrator zugreifen
können. Sie können bis zu fünf IP-Adressen eingeben.
Tabelle 6-3 IP Security-Befehle
Funktion
Befehl
Eine IP-Adresse hinzufügen
ADD IPMANAGER
110 Kapitel 6 Einrichten des Systems