Fabricar: HP
Tamaño del archivo: 611.63 kb
Nombre del archivo:
|
Otros manuales para este modelo:
Resumen del manual
NonStop System Configured for Insight Remote Support Advanced
When a NonStop system has been configured for Insight Remote Support Advanced (as described
in NonStop-Specific Tasks):
•
WEBES subscribes for OSM incident reports.
•
OSM receives the indication subscription from WEBES along with a query for HP_AlertIndication
and the WEBES destination.
•
OSM generates an event 1146 with the trace message “Indication Subscription CREATING.”
The event detail also contains the query and WEBES destination, that destination being a URL
containing 7906, the CMS port used by WEBES to receive incident reports, in the format of
WBEM events, from OSM (see example below).
If two CMSs are configured, there will be an indication subscription and event 1146 created
for each, the first is labeled the Primary, the second is labeled Backup.
NOTE:
If you don't know the WEBES destination, you can search the event log for the most recent
event 1146 with the trace message “Indication Subscription CREATING” – and – that has a URL
containing “7906,” which represents the CMS port used by WEBES to receive incident reports,
in the format of WBEM events, from OSM.
Trace Subject: "Indication Subscription CREATING (Primary)"
Trace Message:- "Subscription: CIM_IndicationSubscription.Filter=R"CIM_IndicationFilter.CreationClassName=\""
"CIM_IndicationFilter\",Name=\"HPWEBES_16.107.145.183_2_Filter_HP_AlertIndication\",SystemCr"
"eationClassName=\"CIM_ComputerSystem\",SystemName=\"System \BLOSM3 [Logical]\"",Handler=R"C"
"IM_IndicationHandlerCIMXML.CreationClassName=\"CIM_IndicationHandlerCIMXML\",Name=\"HPWEBES"
"_16.107.145.183_2_Handler_HP_AlertIndication\",SystemCreationClassName=\"CIM_ComputerSystem"
"\",SystemName=\"System \BLOSM3 [Logical]\""Filter: CIM_IndicationFilter.CreationClassName=""
"CIM_IndicationFilter",Name="HPWEBES_16.107.145.183_2_Filter_HP_AlertIndication",SystemCreat"
"ionClassName="CIM_ComputerSystem",SystemName="System \BLOSM3 [Logical]",Query="select * fro"
"m HP_AlertIndication",QueryLanguage="WQL"" ?10 "Handler: CIM_IndicationHandlerCIMXML.Creati"
"onClassName="CIM_IndicationHandlerCIMXML",Name="HPWEBES_16.107.145.183_2_Handler_HP_AlertIn"
"dication",SystemCreationClassName="CIM_ComputerSystem",SystemName="System \BLOSM3 [Logical]"
"",FaultTolerantState=Primary,Destination="https://16.107.145.183:7906/Wbem/WbemIndication?M"
"EId=90eb11372e176e3f012e177048de0004&MEName=blosm3.caclab.cac.cpqcorp.net&ruleSet=NonStop%3"
"AWBEM_NonStop%3BNonstop_IncidentReportRule%3ANS_IR-9-29-09%3BUX_WIN_WBEM%3AUX_V2_7-24-09""
?10
The first CMS configured for Insight Remote Support Advanced is always considered the “Primary,”
as illustrated in the Trace Subject line above. When a second CMS is configured, it is considered
“Backup” and identified as such in the Trace Subject line: "Indication Subscription
CREATING (Backup)."
DESTA Service Restarted
When DESTA service has been restarted on the CMS:
•
WEBES resends the indication subscription, which includes the WEBES URL to which OSM is
requested to send incident reports.
•
OSM generates an event 1146 with the trace message “Indication Subscription DELETING.”
This occurs only if there is an existing indication subscription – meaning that the DESTA service
had been started previously on the CMS. If not started previously, or the previous indication
subscription had already been deleted by OSM, this event will not be generated.
Trace Subject: "Indication Subscription DELETING (Primary)"
Trace Message:- "Subscription: CIM_IndicationSubscription.Filter=R"CIM_IndicationFilter.CreationClassName=\""
"CIM_IndicationFilter\",Name=\"HPWEBES_16.107.145.183_2_Filter_HP_AlertIndication\",SystemCr"
"eationClassName=\"CIM_ComputerSystem\",SystemName=\"System \BLOSM3 [Logical]\"",Handler=R"C"
"IM_IndicationHandlerCIMXML.CreationClassName=\"CIM_IndicationHandlerCIMXML\",Name=\"HPWEBES"
"_16.107.145.183_2_Handler_HP_AlertIndication\",SystemCreationClassName=\"CIM_ComputerSystem"
"\",SystemName=\"System \BLOSM3 [Logical]\""Filter: CIM_IndicationFilter.CreationClassName=""
"CIM_IndicationFilter",Name="HPWEBES_16.107.145.183_2_Filter_HP_AlertIndication",SystemCreat"
"ionClassName="CIM_ComputerSystem",SystemName="System \BLOSM3 [Logical]",Query="select * fro"
"m HP_AlertIndication",QueryLanguage="WQL"" ?10 "Handler: CIM_IndicationHandlerCIMXML.Creati"
"onClassName="CIM_IndicationHandlerCIMXML",Name="HPWEBES_16.107.145.183_2_Handler_HP_AlertIn"
"dication",SystemCreationClassName="CIM_ComputerSystem",SystemName="System \BLOSM3 [Logical]"
"",FaultTolerantState=Primary,Destination="https://16.107.145.183:7906/Wbem/WbemIndication?M"
"EId=90eb11372e176e3f012e177048de0004&MEName=blosm3.caclab.cac.cpqcorp.net&ruleSet=NonStop%3"
"AWBEM_NonStop%3BNonstop_IncidentReportRule%3ANS_IR-9-29-09%3BUX_WIN_WBEM%3AUX_V2_7-24-09""
?10
22
Description of OSM Event and Data Flow
...