Iniciar sesión:
Votos - 4, Puntuación media: 4.3 ( )

Manual de usuario Mitsubishi, modelo G-50A

Fabricar: Mitsubishi
Tamaño del archivo: 1.31 mb
Nombre del archivo: 5efe2c00-0adf-4be4-a9b0-df9df8bb8b49.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


A brief explanation of each of their function is provided here. / N * To use the maintenance tool via G-50 (Network), license registration for the G-50 to be used is necessary. Purchasing the license No. for each G-50 to be used, conduct the license registration through the Web browser (address of the G-50A]/ administrator.html). After selecting "Maintenance tool" of the optional function on the Web Browser Screen displayed, enter the purchased license No.. For the detail of the license registration, see Chapter 4 [Registering a License for Optional Functions] of Central Controller Model: G-50A Web Browser Operation Manual (For manager). 1.1.1 On-Line Monitor(via MN converter) The On-Line Monitor is connected to the unit by a MN Converter (CMS-MNF) and can monitor such areas as system data, unit data and operating data. (1) In case for local connection Connecting PC installed with the maintenance tool to M-NET transmission line via MN Converter allows conducting various monitoring and setting from the maintenance tool. (2) In case for remote connection Using a modem and remotely connecting PC installed with the maintenance tool to MN Converter via public telephone circuit allow conducting various monitoring and setting as same in the case of local connection. Public network RS-232C MODEM j RS-232C - a d MODEM MN Converter Maintenance Tools PC M-NET *For the remote connection utilizing MN Converter, an isolator is required to be inserted between the modem and MN Converter. For detail, please see Installation Manual-annexing of MN Converter (CMS-MNF). 1 1.1.2 On-Line Monitor(via G-50) The On-Line Monitor is connected to the unit by the central controller(G-50A) and can monitor such areas as system data, unit data and operating data. (1) In case for local connection By directly connecting the PC installed with Maintenance Tools and G-50A through LAN, various monitoring/setting can be performed from the Maintenance Tools. (2)-1 In case for remote connection (Dialup connection mode) By connecting the PC installed with Maintenance Tools and G-50A through public network remotely, various monitoring/setting can be performed from the Maintenance Tools. LAN M-NET r—1^ Maintenance Tool PC (2)-2 In case for remote connection (E-mail connection mode) Under E-mail connection mode, communication can be executed with G-50A through E-mail transmission via mail server. All communication with G-50A is converted into E-mail in this case. Providerl Mail server Mail server Provider2 Mail server Maintenance Tools PC P rovi d e r 2 Access p o i nt G-50A Notice •To use the E-mail connection mode, the version of G-50 should be above 2.60. •When using E-mail connection mode, the local G-50A is required to be initially set with Maintenance Tool and the mail address by the G-50A initial setting tool. - For each mail address, it is required to obtain and set an exclusive one. To transmit mail via an internet provider, obtain the mail address from the provider. When a mail server is existing on the LAN, obtain the mail address from the LAN administrator. - Set the [Pop receive interval] within 3 minutes. However to monitor operating status [Operation Monitor], set it within 1 minute. - Setting of initial information to G-50A can not be executed from Maintenance Tool. Make sure to set it from the G-50A initial setting tool locally. If dialup connection environment is available, it can be set from a remote position. (For detail, please refer to 6-1 Mail Basic Setting in the instruction manual of the G-50A initial setting tool.) • The communication speed under E-mail connection mode largely depends on the transfer rate of each mail server. Under the circumstance, the action of Maintenance Tool may take a lot of time under some internet environments or routing mail servers. V_y 2 1.1.3 Off-Line Monitor The Off-Line Monitor can display, print information obtained by the On-Line Monitor. In the case of connection monitoring utilizing G-50, the operation monitor data collected by G-50A will be transmitted to remote mail servers periodically if the [Operation monitor - mail communication mode] of online mode is adapted. Using this function allows to collect and monitor the operation monitor data without continually connecting the maintenance tool. *For the setting of the [Operation monitor - mail communication mode], refer to 3.7.1 and 4.3.3 description. *Image of the [Operation monitor - mail communication model Operation monitor mail data acquisition Providerl Mail server Maintenance Tools PC Provider2 Mail server Operation monitor data automatic mail transmit LAN Provider 2 Access point Public Router network Collecting the operation monitoring data of air conditioners ~P^ 1 1° J—L G-50A Notice •This differs from the E-mail connection mode of (2)-2 in 1.1.2 On-Line Monitor (via G-50). 1.1.4 Wide area access mode The “Wide area access mode" has been ...

Otros modelos de este manual:
Los acondicionadores de aire - MN Converter (1.31 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría