Iniciar sesión:
Votos - 4, Puntuación media: 4.3 ( )

Manual de usuario KoldFront, modelo PAC8000S

Fabricar: KoldFront
Tamaño del archivo: 204.78 kb
Nombre del archivo: PAC8000S_ownersmanual.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Press the Speed button to select the fan speed. The timer can be used to either turn the unit on or off after a number of elapsed hours. The timer is adjustable between 1-24 hours in one hour increments. How to set the unit to automatically turn on: 1) Press the Timer button on the remote control while the unit is powered off. 2) Use the Up and Down buttons on the remote to set the time (displayed in hours) you want to pass before the unit turns on. After the selected time passes, the unit will automatically turn on. How to set the unit to automatically turn off: 1) Press the Timer button on the remote control while the unit is powered on. The Timer indicator LED will light up 2) Use the Up and Down buttons on the remote to set the time (displayed in hours). The unit will automatically turn off after the selected time elapses. To set the temperature in cooling mode, use the Up and Down buttons on the remote. The temperature range is adjustable between 61°F - 89°F in one degree increments. You can switch the temperature to be displayed in Fahrenheit or Celsius by pressing the .C / .F Button. Fan Only Mode Speed Timer Setting the Temperature Fahrenheit / Celsius NOTE: Fan Only mode does not require that the exhaust hose be attached. NOTE: To cancel the timer, press the Cancel button or Power button. Note: Default setting is in .F. 15 Energy Saving Guide Read and follow the guide below to get the best performance and efficiency from your portable air conditioner: . Do not cover the air outlet (exhaust) while in use. . Do not place the unit in front of curtains or drapes- to ensure they do not obstruct the air intake. . Minimize the length of the exhaust hose. . Make sure the exhaust hose is as straight as possible and avoid kinks or bends. . Keep curtains, blinds or drapes closed during the sunniest part of the day. . Use the timer to operate the unit before it is needed. For example, set the timer to turn on the unit in cooling mode for 3 or more hours to cool the room before you arrive. You may want to operate the unit all day if you live in a warmer climate. . Minimize the heat sources (direct sunlight, computers, servers, people, etc.) in the room. . Close all windows and doors. . Use the unit in a contained room. For example, a room with four walls and a ceiling, instead of a partitioned studio, or warehouse. . Make sure the unit is on a level surface. . Minimize the amount of humidity in the room. For example, run the unit as a dehumidifier. . To prolong the compressor's life, please wait at least 3 minutes before turning the unit back on after shutting it off. . Inspect and keep the pre-filters clean by cleaning regularly. . Inspect and replace the activated carbon filters regularly. . Perform routine maintenance. KoldFront Portable Air Conditioner 16 Maintenance Clean the air conditioner and filters regularly to maximize performance and efficiency, and prolong the unit’s life. Be sure to always unplug the air conditioner from the power outlet before cleaning. Use a soft dry cloth to wipe the body clean. If necessary, use lukewarm water to dampen a cloth to clean the unit. Use a soft bristle brush to clean between the vents. Carefully use a vacuum cleaner to clean the condenser coils. Never use abrasive chemicals, volatile substances, gasoline, detergents, chemically treated cloths, or other cleaning solvents that may damage the cabinet exterior. Never spray water directly on the unit. To clean the pre-filter, follow the steps below: 1) Power off the unit and remove the pre-filter. 2) Remove the activated carbon filter. 3) Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt, then rinse thoroughly under lukewarm running water (below 104°F). You may use a mild soap and water solution if needed. Allow the pre-filter to air dry in a cool and shaded place. Dry thoroughly before reinstalling. Clean the pre-filter periodically. If the unit is used in a dusty environment you may need to clean it on a weekly basis. Warning: Never operate the unit without the filters. If you are not going to be using the unit for an extended period of time, follow the instructions below before storing your unit: 1) Drain all the water from the unit’s reservoir. Operate the unit in fan mode for a few hours to thoroughly dry any moisture left on the coils inside the unit. 2) Power off the unit, and clean or change the filters. 3) Unplug and carefully wind the power cord. 4) Remove the exhaust hose and duct connectors and keep them in a safe place. Cleaning the unit Cleaning the pre-filter Preparation for Storage NOTE: The activated carbon filter is not washable. You should replace it every 2-3 months or as needed. Contact EdgeStar retailers for replacement filters. 17 Troubleshooting Follow the troubleshooting guide below to resolve common issues. Issue Possible Cause Solution My air conditioner is not functioning at all. Unit is not receiving power. Make sure the unit is plugged in to a grounded outlet. LC...

Otros modelos de este manual:
Los acondicionadores de aire - PAC8000S (204.78 kb)
Los acondicionadores de aire - PAC8000S (204.78 kb)
Los acondicionadores de aire - PAC8000S (204.78 kb)
Los acondicionadores de aire - PAC8000S (204.78 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría