Iniciar sesión:
Votos - 5, Puntuación media: 3.8 ( )

Manual de usuario Frigidaire, modelo 2020213A0362

Fabricar: Frigidaire
Tamaño del archivo: 488.1 kb
Nombre del archivo: 2020213A0362en.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


This air conditioner includes a power supply cord with a 3-prong grounding plug. To minimize possible electrical shock hazard: -cord must be plugged into a mating 3-prong grounding-type wall receptacle, -must be grounded in accordance with National Electrical Code (ANSI/NFPA 70 latest version) and -all local codes and ordinances. If a mating 3-prong grounding-type wall receptacle is not available, it is the responsibility of the consumer to have a properly grounded 3-prong wall receptacle installed by a qualified electrician. 3 Prong Grounding Plug Grounding Type Wall Receptacle Grounding prong Power Supply Cord (6 feet long) Preparing for Installation For wood-frame casement windows: It may be necessary to construct a frame, using at least 1-inch thick wood, with a 15-1/2-inch wide opening. For brick or cement building construction: It may be necessary to put a wood stool strip under AC, for mounting purposes. Installation Tips Tools Required Flat-head screwdriver Phillips-head screwdriver Carpenter's level Tape measure Fine tooth saw Electric or hand drill WARNING Failure to adhere to the following precautions could result in personal injury and product damage. Because this unit weighs about 88 to 105 pounds, it is recommended that you have someone help you when install your new unit, and that you both use proper lifting techniques. Inspect the condition of the window where unit will be installed. Be sure it will support the weight of the unit. This appliance must be installed according to all applicable codes and ordinances. Handle AC with care. AVOID sharp metal fins on front and rear coils. Make sure your AC does not fall during installation. Do not use water collected in the unit for drinking purposes. It is not sanitary.Knife and scissors Pencil 2 1. Make sure you have all the necessary parts. Installation kit contents: 1. Platform (1) 2. Support brace (1) 3. Adjustment bolt (1) 4. Hex flange nut - 1/4" (1) 5. Track seal (1) 6. Side channel seal (1) 7. Foam seal strip/Sash seal 8. Safety bracket (1) 9-11. Screw - #10 x 2-1/2" flat-head (2), OR Screw - #10 x 1-3/4" pan-head (2), OR Screw - #10 x 1" pan-head (2) 12. Screw - #8 x 3/4" pan head (6) 13. Screw - #8 x 3/4" self-threading (7) 14. Window locking bracket (1) 15. Plastic window panel (1) 16. Side channel (2) 17. Screw - #8 x 3/8" truss head (6) 18. Panel frame/seal assembly (1) NOTE: Use scale below to measure length of your screws. The scale will come in handy when separating screws for installation. IDENTIFY SCREWS BY LENGTH 2. Choose a proper sized window, as shown right. 15-1/2 inches minimum width 16-1/4 inches maximum width (for casement windows) 21-1/4 inches minimum height (with window panel retainer) 20-5/16 inches minimum height (window panel retainer removed) 39-7/16 inches maximum height NOTE: Height measurement must be of a clear opening above mounting platform. In some cases, due to a variety of stop and track arrangements, the above dimensions may vary slightly. If necessary, installation can be made by alternating window jambs. (See Alternate Window Jamb Applications.) (continued) 3 1 9,10,11 8 2 13 12 5 7 17 4 16 14 15 6 1 1 15 / inches 2 16 / inches 4 minimum maximum width width (casement windows) 20 /516 inches minimum height 39 /716 inches maximum Height 3 3. Choose the proper window location. Choose a window that allows the cooled air to flow freely and directly into room(s) you wish to cool. Remember, it is difficult to move air around corners. Also, choose a window that is within 6 feet of an electrical outlet. (See Meeting Electrical Requirements/Receptacle wiring needs.) Do not use an extension cord. 6 foot power cord reach Installing Unit in a Sliding Window 1. Attach support brace to platform as shown. Use adjustment bolt and hex flange nut to complete assembly. Choose slot and adjustment bolt hole locations that will create a 45 degree angle between platform and support brace. Try assembly in the window to determine if platform will rest properly, and allow proper slope (3/16-inch lower on outside). NOTE: If you are planning to use a siding- protection board (see Step 5) on the outside of your house, hold board in place when testing assembly in window. 2. Measure, and lightly mark a line 8-11/16 inches from window jamb. NOTE: If any sash stop protrudes more than 1 inch from the side window jambs, the 8-11/16-inch measurement must be increased accordingly. Screen and storm window frames may also require adjustments to the measurement. 3. Center platform assembly on the line with inside platform tab pressed against inside edge of window track. Using the holes in the platform as a guide, mark and drill two 9/64-inch diameter holes. Drill holes in either track or stool. CAUTION Property Damage Hazard-Failure to adhere tothe following precaution could result indamage to window or air conditioner. Be sure wood stool or window track is securely attached to the building construction. Use longer screws in sub-framing if neces...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría