Resumen del manual


If you change the setting, the cooling unit will produce a beep. ■ Condition of Automatic Operation Initial room temperature (approx.) Function Temperature setting FAN SPEED Over 27°C ■ ► COOL 27°C HI at start, MED or LOW after the preset temperature is reached Below 27°C ■ ► DEHUMIDIFY Slightly lower than the room temperature LOW - 5 - ENGLISH COOLING OPERATION The maximum and minimum operating temperatures of the hot and cold sides should be as below: If humidity is very high (over 80%) at indoor, some dew may form on the air outlet grille of the cooling unit. Minimum Maximum Indoor Dry bulb °C 21 32 Wet bulb °C 15 23 Outdoor Dry bulb °c 21 43 Wet bulb °c 15 26 Press the FUNCTION selector so that the display indicates 0 (COOL). Set the desired room temperature with the TEMPERATURE button (the display indicates the setting). The range of 25-28°C is recommended as P;^m the room temperature for cooling. If the ■ temperature setting is 27, the room tem- :: ........;_J perature will be controlled at around 27°C. The temperature setting and the actual room temperature may vary somewhat depending on environmental conditions. (MED) : Quiet operation. (LOW) : Quietest operation. -< Set the desired FAN SPEED with the FAN SPEED button (the display indicates the setting). O (AUTO): The FAN SPEED is HI at first and varies to MED or LOW automatically when the preset temperature is reached. (HI) : Maximum operation. Press the 0 (START/STOP) button. Cooling operation starts with a beep. Press the button again to stop operation. The cooling function does not start if the temperature setting is higher than the current room temperature (even though the 0 (OPERATION) lamp lights). The cooling function will start as soon as you set the temperature below the current room temperature. As the settings are stored in memory in the remote controller, you only have to press the ® (START/STOP) button next time. - 6 - DEHUMIDIFYING OPERATION Use the device for dehumidifying when the room temperature is over 16°C. When it is under 15°C, the dehumidifying function will not work. Press the FUNCTION selector so that the display indicates O (DEHUMIDIFY). The FAN SPEED is set at LOW automatically. The FAN SPEED button does not work. Set the desired room temperature with the TEMPERATURE button (the display indicates the setting). The range of 20-26°C is recommended as the room temperature for dehumidifying. -< Press the CD (START/STOP) button. Dehumidifying opera-START\ tion starts with a beep. Press the button again to stop vSTOPy operation. _ ■ As the settings are stored in memory in the remote controller, you only have to press the (!) (START/STOP) button next time. Dehumidifying Function When the room temperature is higher than the setting temperature: The device will dehumidify the room, reducing the room temperature to the preset level. When the room temperature is lower than the temperature setting: Dehumidifying will be performed with the room temperature set slightly lower than the current room temperature, whatever the temperature setting is. The function will stop (the cooling unit will stop emitting air) as soon as the room temperature becomes lower than the setting temperature. - 7 - ENGLISH CIRCULATING OPERATION Press the FUNCTION selector so that the display indicates & (CIRCULATE). Press the FAN SPEED button and select the desired FAN SPEED (the display indicates your choice). Press the temperature control button to set to the desired temperature. < < < Press the © (START/STOP) button. Circulating operation starts with a beep. Press the button again to stop operation. ■ As the settings are stored in memory in the remote controller, you only have to press the CD (START/STOP) button next time. When the room temperature is higher than the temperature set by the thermostat, only the fan operates to circulate the upper hotter air downwards. This makes temperature distribution of the room even at heating. This operation is useful in winter when using other heating equipment. - 8 - FAN OPERATION You can use the device simply as an air circulator. Use this function to dry the interior of the cooling unit at the end of summer. Press the FUNCTION selector so that the display indicates + (FAN). Press the FAN SPEED button and select the desired FAN SPEED (the display indicates your choice). START\ Press the (D (START/STOP) button. Fan operation starts STOP/ with a beep. Press the button again to stop operation. ■< -< - 9 - ENGLISH TIMER SET BUTTONS HOW TO SET THE TIMER r Setting the Current Time After you change the batteries; \ \ J / , _am ( (_/ • Q Q - yyU-bfr 1 Press the © (TIME) button. SELECT (Timer mode) TIME (Current time) CANCEL RESERVE 0 O -k. n-nn “ — u • u u ~ // I \" r OFF-Timer 1 Press the 0®, (SELECT) button until the o (OFF) mark blinks on the display. You can set the device to turn off at the preset time. oS, O u • u u ON-T...

Otros modelos de este manual:
Los acondicionadores de aire - BCC-12I (766.89 kb)
Los acondicionadores de aire - BCC-9E (766.89 kb)
Los acondicionadores de aire - BCC-9I (766.89 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría